background image

BLOWER PERFORMANCE SPECIFICATIONS

12

1.

CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return
filters, this chart assumes both filters are installed.

2.

All furnaces ship as high speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.

3.

For most jobs, about 400 CFM per ton when cooling is desirable.

4.

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

5.

The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded
area indicates ranges in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown for
air conditioning purposes only.

6.

The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly de-rated unit will have approximately the same
temperature rise at a particular CFM, while the ESP at that CFM will be lower.

Tons  A C

at 0.5"

0.6

0.7

0.8

E S P

CF M RIS E CF M RIS E CF M RIS E CFM RIS E CF M RIS E CF M CF M CF M

H IG H

3 .0

1352

29

1318

30

1260

31

1202

33

1128

35

1044

955

853

G MH 9 5 0 4 5 3 B XA*

ME D   2 .5

1214

32

1172

34

1123

35

1064

37

1012

39

938

859

741

(ME D -H I)

ME D -L O

2 .0

997

40

994

40

960

41

923

43

884

45

817

741

611

L O W

1 .5

757

52

753

52

734

54

704

56

674

59

620

524

438

H IG H

3 .0

1449

41

1409

42

1326

45

1273

47

1201

49

1194 1136 1018

G MH 9 5 0 7 0 3 B XA*

ME D

2 .5

1192

50

1172

51

1141

52

1094

54

1046

57

973

904

793

(ME D -H I)

ME D -L O

2 .0

981

61

962

62

943

63

917

65

888

67

830

764

665

L O W

1 .5

750

79

730

81

714

83

692

86

657

90

620

570

502

H IG H

4 .0

2069

29

1965

30

1871

32

1756

34

1661

36

1549 1415 1275

G MH 9 5 0 7 0 4 C XA*

ME D

3 .5

1752

34

1724

34

1667

36

1603

37

1488

40

1402 1290 1082

(ME D -H I)

ME D -L O

3 .0

1437

41

1437

41

1417

42

1369

43

1320

45

1256 1140

984

L O W

2 .5

1184

50

1177

50

1161

51

1132

52

1095

54

1047

928

837

H IG H

4 .0

1970

40

1874

342

1757

45

1667

48

1566

51

1431 1334 1182

G MH 9 5 0 9 0 4 C XA*

ME D   3 .5

1713

46

1650

48

1572

50

1510

52

1418

56

1313 1211 1079

(ME D -H I)

ME D -L O

3 .0

1439

55

1412

56

1370

58

1327

60

1260

63

1166 1078

956

L O W

2 .5

1183

67

1155

69

1122

74

1108

72

1062

75

1011

931

816

H IG H

5 .0

2058

39

1997

40

1928

42

1852

43

1777

45

1682 1600 1487

G MH 9 5 0 9 0 5 C XA*

ME D   4 .0

1718

47

1685

48

1632

49

1586

51

1520

53

1458 1369 1281

(ME D -H I)

ME D -L O

3 .5

1502

54

1464

55

1429

56

1380

58

1319

61

1272 1200 1137

L O W

3 .0

1305

62

1277

63

1253

64

1212

66

1175

69

1127 1081 1010

H IG H

5 .0

2147

37

2114

37

2057

39

2030

39

1978

40

1889 1784 1713

G MH 9 5 0 9 0 5 D XA*

ME D   4 .0

1675

47

1686

47

1640

48

1623

49

1557

51

1501 1455 1360

(ME D -H I)

ME D -L O

3 .5

1489

53

1470

54

1436

55

1409

56

1361

58

1318 1243 1130

L O W

3 .0

1307

61

1265

63

1234

64

1203

66

1168

68

1096 1053

991

H IG H

5 .0

2134

46

2103

47

2029

48

1941

51

1906

51

1818 1733 1625

G MH 9 5 1 1 5 5 D XA*

ME D   4 .0

1678

58

1643

60

1643

60

1577

62

1527

64

1489 1423 1339

(ME D -H I)

ME D -L O

3 .5

1453

68

1440

68

1426

69

1363

72

1349

73

1314 1253 1205

L O W

3 .0

1259

78

1239

79

1220

80

1181

83

1159

85

1118 1082 1015

 BLO W ER P ERF O RM ANCE

0.1

0.2

0.3

0.4

0.5

(CF M   &  T e m p e ra tu re   Rise   vs.  Ex te rn a l  S ta tic  P re ssu re )

Model

Heating Speed

A s   Shipped

M otor 

S peed

E XTE RNA L  S TA TIC  P RE S S URE   (Inc hes   W ater  Colum n)

(

)

Содержание GMH95

Страница 1: ...og for part number information Model numbers listed on page 3 Copyright 2007 2009 2010 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL...

Страница 2: ...onnect ALL power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage personal injury or death Installation and repair of this unit...

Страница 3: ...o follow these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office...

Страница 4: ...rts in Service Instructions General Operation The GMH95 furnaces are equipped with an electronic igni tion device used to light the burners and an induced draft blower to exhaust combustion products A...

Страница 5: ...as Line Entrance 14 Flue Pipe Connection Alternate 15 Rubber Elbow 16 Induced Draft Blower 17 Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20...

Страница 6: ...SIDE CUT OUT LOW VOLTAGE ELECTRICAL HOLE RIGHT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE DRAIN TRAP 19 3 4 AIR INTAKE PIPE 2 PVC LEFT SIDE DRAIN LINE HOLES 1 5 8 RIGHT SIDE VIEW CONDENSATE DRAIN...

Страница 7: ...5 0 10 0 10 20197308 1 35 0130F00110 TBD TBD TBD GMH950905DXA 1 30 1 10 0 52 0 37 0 37 20197312 1 10 0130F00000P TBD TBD TBD GMH951155DXA 1 30 1 10 0 75 0 60 0 60 20197310 1 10 0130F00000P TBD TBD TBD...

Страница 8: ...LIMIT Part Number 10123514 or 10123533 10123517 Open Setting F 200 210 GMH950453BXA 1 GMH950703BXA 2 GMH950704CXA 2 GMH950904CXA 2 GMH950905CXA 2 GMH950905DXA 2 GMH951155DXA 2 ROLLOUT LIMIT SWITCHES...

Страница 9: ...C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C...

Страница 10: ...filter face velocity Minimum filter area dictated by heating airflow requirement Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 Cabinet Width in Nominal Filter Size in Approx Flow Area...

Страница 11: ...MH95 0703BXA GMH95 0704CXA GMH95 0904CXA GMH95 0905CXA GMH95 0905DXA GMH95 1155DXA Btuh Input US 46 000 69 000 69 000 92 000 92 000 92 000 115 000 Output US 44 400 66 400 66 900 89 000 88 400 88 400 1...

Страница 12: ...57 973 904 793 MED H I MED LO 2 0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1 5 750 79 730 81 714 83 692 86 657 90 620 570 502 H IGH 4 0 2069 29 1965 30 1871 32 1756 34 1661 36 1549 1415 127...

Страница 13: ...0 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULA...

Страница 14: ...FIELD SPLICE SWITCH TEMP OR 24V THERMOSTAT CONNECTIONS GR GND 115 VAC 24 VAC BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN DOOR SWITCH BK GND L N WH JUNCTION BOX 1 OR ID BLOWER PRESSURE SWITCH H...

Страница 15: ...ITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD O...

Страница 16: ...COMPARTMENT DOORSWITCH OPENWHEN DOOROPEN DOOR SWITCH WARNING DISCONNECTPOWERBEFORE SERVICING WIRINGTOUNITMUSTBE PROPERLYPOLARIZEDANDGROUNDED BK GND DISCONNECT L N WH JUNCTION BOX 1 OR IDBLOWER PRESSU...

Отзывы: