background image

Contents

Nomenclature ....................................... 2
Product Specifications .......................... 3
Dimensions ........................................... 4
Airflow Data .......................................... 6
Wiring Diagrams ................................. 11
Thermostats  ....................................... 12
Accessories .......................................... 12

Standard Features

•  Aluminized-steel, dual-diameter tubular heat exchanger
•  Stainless-steel secondary heat exchanger
•  ComfortNet

TM

 Communicating Systems compatible

•  Self-calibrating, modulating gas valve operates 

with two-stage or single-stage thermostats

•  Efficient and quiet variable-speed circulator motor 
•  Furnace control board with self-diagnostics and  

provisions for electronic air cleaners and humidifiers

•  Multiple continuous fan speed  

options for quiet air circulation

•  Dual-certified for sealed combustion direct vent  

(2-pipe) or non-direct vent (1-pipe) applications

•  Auto-Comfort and enhanced dehumidification  

modes provide energy savings and additional  
comfort during the cooling months

•  Quiet variable-speed induced draft blower
•  All models comply with California NOx emissions standards

*  Complete  warranty  details  available  from  your  local  dealer  or  at  www.goodmanmfg.com.  To  receive  the  Lifetime  Heat 

Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-
Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not 
required in California or Québec.

Cabinet Features

•  Cabinet air leakage (Q

Leak

) ≤ 2%

•  Fully insulated heavy-gauge steel cabinet  

with durable baked-enamel finish

•  Foil-faced insulation lines the heat exchanger section
•  Designed for multi-position installation
•  Airtight solid bottom for side-return applications and easy-cut 

tabs for effortless removal in bottom air-inlet applications

•  Convenient left or right connection for gas and electric service
•  Coil and furnace fit flush for most installations

SS-GMVM96

www.goodmanmfg.com

1/13

Supersedes 3/12

GMVM96 / GCVM96

C

oMfort

N

et

-C

oMpatible

,

M

ulti

-p

ositioN

, M

odulatiNG

 

V

ariable

-s

peed

 G

as

 f

urNaCe

u

p

 

to

 96% afue

Содержание GCVM96

Страница 1: ...All models comply with California NOx emissions standards Complete warranty details available from your local dealer or at www goodmanmfg com To receive the Lifetime Heat Exchanger Limited Warranty g...

Страница 2: ...Natural Gas H High Air ow X Low NOx K Dedicated Up ow M Up ow Horizontal Cabinet Width A 14 Descrip6on Motor B 17 V Two Stage Variable speed C 21 H Two Stage Mul speed D 24 S Single Stage Mul speed E...

Страница 3: ...2 14 2 6 0 14 2 14 2 Max Overcurrent Protection 15 0 15 0 15 0 15 0 15 0 15 0 15 0 Ship Weight lbs 135 145 170 170 139 165 170 Natural Gas BTU h DOE AFUE based upon Isolated Combustion System ICS Ins...

Страница 4: ...d one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional Combustion Air Pip...

Страница 5: ...21 19 16 18 19 GCVM960805DX 24 28 40 24 23 20 21 23 GCVM961005DX 24 28 40 24 23 20 21 23 Notes Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet r...

Страница 6: ...ESP GMVM961005DX GMVM961155DX High Stage Low Stage High Stage Low Stage Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM A Minus 711 A Minus 459 A Minus 711 A Minus 459 Normal 790 Normal 51...

Страница 7: ...DX Rise Range 35 65 F Adjust Tap CFM Rise F Adjust Tap CFM Rise F Minus 1 629 54 Minus 1 629 62 Normal 1 810 49 Normal 1 810 56 Plus 1 991 44 Plus 1 991 51 Minus 1 665 53 Minus 1 665 60 Normal 1 850 4...

Страница 8: ...7 Plus 1078 Plus 2068 Plus 1342 1 8 w c ESP Notes All furnaces ship as high speed for cooling Installer must adjust blower speed as needed For most jobs about 400 CFM per ton when cooling is desirable...

Страница 9: ...nus 1 719 41 Normal 1 590 33 Normal 1 910 37 Plus 1 749 30 Plus 2 101 34 1 5 w c ESP 1 5 w c ESP GCVM961005DX Rise Range 25 55 F Adjust Tap CFM Rise F Minus 1 557 56 Normal 1 730 51 Plus 1 903 46 Minu...

Страница 10: ...0 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Страница 11: ...NY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE USED WHEN SERVICING 2 MANUFACTURER S SPECIFIED REPLACEMENT PARTS MUST BE 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS BK BLACK PU PURPLE YL YELLOW...

Страница 12: ...KM0D100UF LPKM0D115UF LPKM0D060CF LPKM0D080CF LPKM0D100CF EFR01 External Filter Rack DCVK 20 Horizontal Vertical Concentric Vent Kit 2 DCVK 30 Horizontal Vertical Concentric Vent Kit 3 CFB21 Downflow...

Отзывы: