background image

3

Dear Homeowner, please recognize the following safety in-
formation.  This information will alert you to the potential
for personal injury.

WARNING

 - Indicate hazards or unsafe practices which

COULD 

 result in severe personal injury or death.

T

HIS

 

PRODUCT

 

CONTAINS

 

OR

 

PRODUCES

 

A

 

CHEMICAL

 

OR

 

CHEMICALS

 

WHICH

 

MAY

 

CAUSE

 

SERIOUS

 

ILLNESS

 

OR

 

DEATH

 

AND

 

WHICH

 

ARE

 

KNOWN

 

TO

 

THE

 S

TATE

 

OF

 C

ALIFORNIA

 

TO

 

CAUSE

 

CANCER

BIRTH

 

DEFECTS

 

OR

 

OTHER

 

REPRODUCTIVE

 

HARM

.

WARNING

T

O

 

AVOID

 

POSSIBLE

 

EQUIPMENT

 

DAMAGE

PERSONAL

 

INJURY

FIRE

 

OR

 

DEATH

THE

 

FOLLOWING

 

INSTRUCTIONS

 

MUST

 

BE

 

OBSERVED

 

REGARDING

 

UNIT

 

LOCATION

AIR

 

REQUIREMENTS

 

AND

 

OPERATING

 

PROCEDURES

.

WARNING

H

EATING

 

UNIT

 

SHOULD

 

NOT

 

BE

 

UTILIZED

 

WITHOUT

 

REASONABLE

ROUTINE

INSPECTION

MAINTENANCE

 

AND

 

SUPERVISION

. I

F

 

THE

 

BUILDING

 

IN

 

WHICH

 

ANY

 

SUCH

 

DEVICE

 

IS

 

LOCATED

 

WILL

 

BE

 

VACANT

CARE

 

SHOULD

 

BE

 

TAKEN

 

THAT

 

SUCH

 

DEVICE

 

IS

 

ROUTINELY

 

INSPECTED

MAINTAINED

 

AND

 

MONITORED

IN

 

THE

 

EVENT

 

THAT

 

THE

 

BUILDING

 

MAYBE

 

EXPOSED

 

TO

 

FREEZING

 

TEMPERATURES

 

AND

 

WILL

 

BE

 

VACANT

ALL

 

WATER

-

BEARING

 

PIPES

 

SHOULD

 

BE

 

DRAINED

THE

 

BUILDING

 

SHOULD

 

BE

 

PROPERLY

 

WINTERIZED

AND

 

THE

 

WATER

 

SOURCE

 

CLOSED

IN

 

THE

 

EVENT

 

THAT

 

THE

 

BUILDING

 

MAY

 

BE

 

EXPOSED

 

TO

 

FREEZING

 

TEMPERATURES

 

AND

 

WILL

 

BE

 

VACANT

ANY

 

HYDRONIC

 

COIL

 

UNITS

 

SHOULD

 

BE

 

DRAINED

 

AS

 

WELL

 

AND

IN

 

SUCH

 

CASE

ALTERNATIVE

 

HEAT

 

SOURCES

 

SHOULD

 

BE

 

UTILIZED

.

WARNING

I

MPORTANT

 N

OTE

 

TO

 

THE

 O

WNER

 

REGARDING

 P

RODUCT

L

IMITED

 W

ARRANTY

Your limited warranty certificate is supplied as a separate
document with the unit installed by your contractor. Read
the limited warranty certificate carefully to determine what
is and is not covered and keep the warranty certificate in a
safe place. If you are unable to locate the warranty certifi-
cate please contact your installing contractor or contact
customer service (877-254-4729) to obtain a copy.

Before using this manual, check the serial plate for

proper model identification.

The installation and servicing of this equipment must be

performed by qualified, experienced technicians only.

U

NIT

 L

OCATION

1. The furnace area and the vicinity of any other gas appli-

ances must be kept clear and free of combustible mate-
rials, gasoline, and other flammable vapors and liquids.
Also, do not store or use flammable items such as paint,
varnish, or lacquer in the area.

2. Do not store or use chlorine or fluorine products

(bleaches, cements, strippers, aerosols) near the unit.
They can corrode the heat exchanger.

3. Do not use the furnace closet as storage for brooms,

mops, brushes and oily rags or cloths. The area must be
kept clear, clean and free of lint. Furnace must be kept
free and clear of exposed or loose insulation materials
in the area of installation. Examine the furnace area
when the furnace or additional insulation is added since
some insulation materials may be combustible.

4. Make sure the furnace is always connected to an ap-

proved vent, in good condition, to carry combustion prod-
ucts outdoors.

5. Familiarize yourself with the controls that shut off the

gas and electrical power to the furnace. If the furnace
is to be shut down at the end of the heating season,
turn off both the gas and electrical power. For safety,
always turn the gas and electrical power off before per-
forming service or maintenance on the furnace.

6. Establish a regular maintenance schedule to insure effi-

cient and safe operation of the furnace. The furnace
should be checked at the beginning of each heating and
cooling season by a qualified service technician.

T

O

 

AVOID

 

PERSONAL

 

INJURY

 

OR

 

FIRE

MINIMUM

 

CLEARANCES

 

TO

 

COMBUSTIBLE

 

SURFACES

 

MUST

 

BE

 

FOLLOWED

.

WARNING

7. Make certain the required clearances for the furnace

are always maintained. These clearances are listed on
the furnace clearance label. If any question develops,
contact the installer of the furnace or another qualified
servicer.

U

NIT

 I

NSTALLATION

Examine the furnace installation to determine the follow-
ing:

1. All flue product carrying passages external to the fur-

nace (i.e. chimney, vent connector) are clear and free
of obstructions.

2. The vent connector is in place, slopes upward and is

physically sound without holes or excessive corrosion.

3. The return air duct connection is physically sound, sealed

to the furnace casing, and terminates outside the space
containing the furnace.

4. The physical support of the furnace is sound without

sagging, cracks, or gaps around the base so as to pro-
vide a seal between the support and the base.

5. There are no obvious signs of deterioration of the fur-

nace.

6. Check for proper burner flame performance. Flame

should extend directly outward from burners without
curling, floating, or lifting off.

Содержание GCSS960804CN

Страница 1: ...MAY CAUSE LUNG CANCER FIBERGLASS WOOL IS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER TO REDUCE EXPOSURE OR FOR FURTHER INFORMATION CONSULT MATERIAL SAFETY DATA SHEETS AVAILABLE FROM THE ADDRESS S...

Страница 2: ...quirements 4 Combustion Air 4 Indoor Humidity 5 Propane LP Gas Installations Only 5 Thermostat Functions 5 Furnace Operation 6 FURNACE START UP 6 FURNACE SHUT DOWN 6 LOCKOUT RESET 6 Routine Maintenanc...

Страница 3: ...flammable items such as paint varnish or lacquer in the area 2 Do not store or use chlorine or fluorine products bleaches cements strippers aerosols near the unit They can corrode the heat exchanger...

Страница 4: ...xide CO poisoningresultingfromtheexhaustemissions Ifafurnaceorairhandlerisinstalledinanenclosedareaand a devices suchasautomobiles spaceheaters gas waterheaters etc shouldnotbeoperatedinenclosedareass...

Страница 5: ...ON it will run continuously regardless of whether or not heating or cooling is being provided In addition there are thermostats which automatically switch from heating to cooling mode and those with...

Страница 6: ...ckout is characterized by a non functioning fur nace circulator blower may be running continuously pro viding a diagnostic LED code Lockout results when a fur nace control detects abnormal conditions...

Страница 7: ...FILTERS OR PERFORMING ANY OTHER MAINTENANCE NEVER OPERATE FURNACE WITHOUT A FILTER INSTALLED BECAUSE DUST AND LINT WILL BUILD UP ON INTERNAL PARTS RESULTING IN LOSS OF EFFICIENCY EQUIPMENT DAMAGE OR P...

Страница 8: ...s outlined in the following bullet points Do not attempt repairs yourself Check the blower compartment sight glass If LED is flashing record the number of flashes seen in sequence shutdown your unit a...

Страница 9: ...r ordering information DU GAZ ARRIVEE INLET GAS IN ON POS LEVER SHOWN MANUAL GAS ON MARCHE MANUEL EN POS ROBINET A GAZ IN ON POS LEVER SHOWN MANUAL GAS DU GAZ ARRIVEE INLET GAS DU GAZ ARRIVEE INLET GA...

Страница 10: ...ler is installed in an enclosed area such as garage utility room or parking area and a carbon monoxide producing device is operated therein there must be adequate direct outside ventilation Carbon mon...

Страница 11: ...11 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 12: ...l Number of the unit must be supplied These numbers are recorded on the nameplate of the furnace For conve nience record this information here CONSUMER INFORMATION LINE TOLL FREE 1 877 254 4729 U S on...

Отзывы: