54
PERFORMANCE DATA
HIGH STAGE
DSXC160[48-60]1B*
Outdoor
Te m p. ° F.
Total
Btuh
Se ns ible
Btuh
Late nt
Btuh
Total
Watts
75°
59,900
41,930
17,970
4,120
80°
59,150
41,997
17,154
4,260
85°
58,400
42,048
16,352
4,400
90°
57,700
42,121
15,579
4,525
95°
57,000
42,180
14,820
4,650
100°
55,600
41,978
13,622
4,755
105°
54,200
41,734
12,466
4,860
110°
52,200
40,194
12,006
4,950
115°
50,200
38,654
11,546
5,040
95°
52,818
43,021
9,797
4,823
TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
*SXC160601B* / CA*F496*6**+TXV / MBVC2000**-1**
Conditions: 80°F IDB, 67°F IW B @ 1800 CFM, High Stage
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
49,350
35,434
13,916
3,331
80°
48,763
35,457
13,305
3,445
85°
48,175
35,470
12,705
3,559
90°
47,588
35,602
11,986
3,660
95°
47,000
35,720
11,280
3,760
100°
45,825
35,487
10,338
3,845
105°
44,650
35,220
9,430
3,931
110°
43,005
34,064
8,941
4,005
115°
41,360
32,898
8,462
4,078
95°
22,200
16,650
5,550
1,770
DSXC160481B* / CA*F4961*6**+TXV / MBVC2000**-1
Conditions: 80°F IDB, 67°F IWB @ 1550 CFM, High Stage
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
DSXC160[48-60]1B*
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute
(CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1.
As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures
and power will not change.
2.
As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side
pressures and power.
A properly operating unit should be within the subcooling value shown in the Air Conditioner Specifications.
A properly operating unit should be within plus or minus
3 degrees
of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus
7 PSIG
of the
HI PR
shown.
A properly operating unit should be within plus or minus
3 PSIG
of the
LO PR
shown.
A properly operating unit should be within plus or minus
3 Amps
of the typical value shown.
NOTE: Pressures are measured at the liquid and suction service valve ports.
LOW STAGE
Outdoor
Te m p. ° F.
Total
Btuh
Se ns ible
Btuh
Late nt
Btuh
Total
Watts
75°
42,700
29,463
13,237
2,810
80°
42,200
29,540
12,660
2,905
85°
41,700
29,607
12,093
3,000
90°
41,150
29,628
11,522
3,085
95°
40,600
29,638
10,962
3,170
100°
39,600
29,502
10,098
3,240
105°
38,600
29,336
9,264
3,310
110°
37,200
28,458
8,742
3,375
115°
35,800
27,566
8,234
3,440
95°
39,515
31,447
8,067
3,231
TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
DSXC160601B* / CA*F496*6**+TXV / M BV C2000**-1 **
Conditions : 80°F IDB, 67°F IWB @ 1400 CFM , LOW STAGE
Outdoor
Te m p. ° F.
Total
Btuh
Se ns ible
Btuh
Late nt
Btuh
Total
Watts
75°
36,750
24,304
12,446
2,067
80°
36,313
24,320
11,993
2,182
85°
35,875
24,329
11,547
2,297
90°
35,438
24,419
11,018
2,399
95°
35,000
24,500
10,500
2,500
100°
34,125
24,340
9,785
2,586
105°
33,250
24,157
9,093
2,672
110°
32,025
23,364
8,661
2,747
115°
30,800
22,565
8,236
2,821
95°
32,071
25,004
7,067
2,515
TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
DSXC160481A* / CA*F4961*6** +TXV / M BV C2000**-1B*
Conditions : 80°F IDB, 67°F IWB @ 950 CFM , LOW STAGE