background image

3

T

HIS

 

UNIT

 

MUST

 

NOT

 

BE

 

USED

 

AS

 

A

 “

CONSTRUCTION

 

HEATER

” 

DURING

 

THE

 

FINISHING

 

PHASES

 

OF

 

CONSTRUCTION

 

ON

 

A

 

NEW

 

STRUCTURE

. T

HIS

 

TYPE

 

OF

 

USE

 

MAY

 

RESULT

 

IN

 

PREMATURE

 

FAILURE

 

OF

 

THE

 

UNIT

 

DUE

 

TO

 

EXTREMELY

 

LOW

 

RETURN

 

AIR

 

TEMPERATURES

 

AND

 

EXPOSURE

 

TO

 

CORROSIVE

 

OR

 

VERY

 

DIRTY

 

ATMOSPHERES

.

WARNING

HIGH VOLTAGE! 

D

ISCONNECT

 

ALL

 

POWER

 

BEFORE

 

SERVICING

 

OR

 

INSTALLING

 

THIS

 

UNIT

. M

ULTIPLE

 

POWER

 

SOURCES

 

MAY

 

BE

 

PRESENT

. F

AILURE

 

TO

 

DO

 

SO

 

MAY

 

CAUSE

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

.

WARNING

WARNING

T

O PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,

DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER
FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.

GENERAL INFORMATION

T

O

 

PREVENT

 

PROPERTY

 

DAMAGE

 

PERSONAL

 

INJURY

 

OR

 

DEATH

DUE

 

TO

 

FIRE

EXPLOSIONS

SMOKE

SOOT

CONDENSATION

ELECTRIC

 

SHOCK

 

OR

 

CARBON

 

MONOXIDE

THIS

 

UNIT

 

MUST

 

BE

 

PROPERLY

 

INSTALLED

REPAIRED

OPERATED

AND

 

MAINTAINED

.

WARNING

This unit is approved for outdoor installation ONLY.

Rated performance is achieved after 72 hours of opera-
tion. To assure that your unit operates safely and efficiently,
it must be installed, operated, and maintained in accor-
dance with these installation and operating instructions,
all local building codes and ordinances.

EPA R

EGULATIONS

I

MPORTANT

: T

HE

 U

NITED

 S

TATES

 E

NVIRONMENTAL

 P

ROTECTION

A

GENCY

 (EPA) 

HAS

 

ISSUED

 

VARIOUS

 

REGULATIONS

 

REGARDING

THE

 

INTRODUCTION

 

AND

 

DISPOSAL

 

OF

 

REFRIGERANTS

 

IN

 

THIS

UNIT

. F

AILURE

 

TO

 

FOLLOW

 

THESE

 

REGULATIONS

 

MAY

 

HARM

 

THE

ENVIRONMENT

 

AND

 

CAN

 

LEAD

 

TO

 

THE

 

IMPOSITION

 

OF

SUBSTANTIAL

 

FINES

. B

ECAUSE

 

REGULATIONS

 

MAY

 

VARY

 

DUE

 

TO

PASSAGE

 

OF

 

NEW

 

LAWS

WE

 

SUGGEST

 

A

 

CERTIFIED

 

TECHNICIAN

PERFORM

 

ANY

 

WORK

 

DONE

 

ON

 

THIS

 

UNIT

. S

HOULD

 

YOU

 

HAVE

ANY

 

QUESTIONS

 

PLEASE

 

CONTACT

 

THE

 

LOCAL

 

OFFICE

 

OF

 

THE

EPA.

N

ATIONAL

 C

ODES

This product is designed and manufactured to permit  instal-
lation in accordance with National Codes. It is the installer’s
responsibility to install the product in accordance with Na-
tional Codes and/or prevailing local codes and regulations.

The heating and cooling capacities of the unit should be
greater than or equal to the design heating and cooling loads
of the area to be conditioned. The loads should be calculated
by an approved method or in accordance with ASHRAE Guide
or Manual J - Load Calculations published by the Air Condi-
tioning Contractors of America.

Obtain from:

American National Standards Institute

1430 Broadway

New York, NY 10018

System design and installation should also, where applicable,
follow information presented in accepted industry guides such
as the ASHRAE Handbooks. The manufacturer assumes no
responsibility for equipment installed in violation of any code
or regulation. The mechanical installation of the packaged
roof top units consists of making final connections between
the unit and building services; supply and return duct con-
nections; and drain connections (if required).  The internal
systems of the unit are completely factory-installed and tested
prior to shipment.

Units are generally installed on a steel roof mounting curb
assembly which has been shipped to the job site for installa-
tion on the roof structure prior to the arrival of the unit.  The
model number shown on the unit’s identification plate identi-
fies the various components of the unit such as refrigeration
tonnage, heating input and voltage.

Carefully inspect the unit for damage including damage to

the cabinetry.  Any bolts or screws which may have loosened

in transit must be re-tightened.  In the event of damage, the

receiver should:

1. Make notation on delivery receipt of any visible

damage to shipment or container.

2. Notify carrier promptly and request an inspection.
3. In case of concealed damage, carrier should be

notified as soon as possible-preferably within 5 days.

4. File the claim with the following supporting documents:

a. Original Bill of Lading, certified copy, or indemnity

bond.

b. Original paid freight bill or indemnity in lieu thereof.
c. Original invoice or certified copy thereof, showing

trade and other discounts or reductions.

d. Copy of the inspection report issued by carrier

representative at the time damage is reported to the
carrier. The carrier is responsible for making prompt
inspection of damage and for a thorough
investigation of each claim. The distributor or
manufacturer will not accept claims from dealers for
transportation damage.

Содержание CPC036

Страница 1: ...NSTALLING PERSONNEL Prior to installation thoroughly familiarize yourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed It is your responsibility to install the product safely and to educate the customer on its safe use NOTE Please contact your distributor or our website for the applicable Specification Sheet referred to in this m...

Страница 2: ...RMANCE AND OR HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OF SUCH NON APPROVED DEVICES WARNING Index Replacement Parts 2 Safety Instructions 2 General Information 3 Unit Location 4 Clearances 5 Roof Curb Post Installation Checks 5 Roof Top Duct Connections 6 Rigging Details 6 Electrical Wiring 8 Circulating Air and Filters 10 Venting 10 Condensate Drain Connection 10 Startup Adjustments and Check...

Страница 3: ...qual to the design heating and cooling loads of the area to be conditioned The loads should be calculated by an approved method or in accordance withASHRAE Guide or Manual J Load Calculations published by the Air Condi tioning Contractors of America Obtain from American National Standards Institute 1430 Broadway New York NY 10018 System design and installation should also where applicable follow i...

Страница 4: ...ake motorized fresh air intake too close to an exhaust outlet gas vent termination or plumbing vent outlet For specific distances required consult local codes Allow minimum clearances from the enclosure for fire protection proper operation and service access see Unit Clearances These clearances must be permanently maintained When the unit is heating the temperature of the return air entering the u...

Страница 5: ...on before unit placement Duct installation after unit placement is not recommended ALL CURBS LOOK SIMILAR TO AVOID INCORRECT CURB POSITIONING CHECK JOB PLANS CAREFULLY AND VERIFY MARKINGS ON CURB ASSEMBLY INSTRUCTIONS MAY VARY IN CURB STYLES AND SUPERSEDES INFORMATION SHOWN CAUTION See the manual shipped with the roof curb for assembly and installation instructions CLEARANCES 48 75 48 UNIT CLEARAN...

Страница 6: ... FORK LENGTH IS 42 TO PREVENT DAMAGE TO THE UNIT HOWEVER 48 IS RECOMMENDED CAUTION Provisions for forks have been included in the unit base frame No other fork locations are approved WARNING TO PREVENT POSSIBLE EQUIPMENT DAMAGE PROPERTY DAMAGE PERSONAL INJURY OR DEATH THE FOLLOWING BULLET POINTS MUST BE OBSERVED WHEN INSTALLING THE UNIT Unit must be lifted by the four lifting holes located at the ...

Страница 7: ...COMPRESSOR Y X CORNER CENTER OF GRAVITY LOCATIONS A B C D CPC036 35 27 525 500 115 150 105 130 CPC048 35 27 560 535 125 160 110 140 CPC060 35 27 605 580 135 170 120 155 CPC072 35 27 665 640 150 190 130 170 CPH036 34 28 605 580 130 180 110 155 CPH048 34 28 610 585 135 185 115 155 CPH060 34 28 615 590 135 185 115 160 CPH072 34 28 675 650 145 205 125 175 Operating Weight lbs Corner Weights lbs Weight...

Страница 8: ...done in accordance with these instructions the latest edition of the National Electrical Code ANSI NFPA 70 and all local codes and ordinances All field wiring shall conform with the temperature limitations for Type T wire 63 F 35 C rise The unit is factory wired for the voltage shown on the unit s data plate Refer to model nomenclature in Appendix D for voltage requirement for your unit NOTE If su...

Страница 9: ...W VOLTAGE CONTROL WIRING 1 A 24V thermostat must be installed for unit operation It may be purchased with the unit or field supplied Thermostats may be programmable or electromechanical as required 2 Locate thermostat or remote sensor in the conditioned space where it will sense average temperature Do not locate the device where it may be directly exposed to supply air sunlight or other sources of...

Страница 10: ...MEANS DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK B WARNING PRE STARTUP INSTRUCTIONS TO PREVENT PROPERTY DAMAGE OR PERSONAL INJURY DO NOT START THE UNIT UNTIL ALL NECESSARY PRE CHECKS AND TESTS HAVE BEEN PERFORMED CAUTION Prior to the beginning of Startup Adjustments and Checks procedures the following steps should be comp...

Страница 11: ...of disconnect agrees with voltage on unit identification plate and is within the utilization voltage range as indicated in Ap pendix C Electrical Data System Voltage That nominal voltage value assigned to a circuit or system for the purpose of designating its voltage class Nameplate Voltage That voltage assigned to a piece of equipment for the purpose of designating its voltage class and for the p...

Страница 12: ... charged and tested making it unnecessary to field charge Factory charges are shown on the unit nameplate Install service manifold hoses Gauges should read satura tion pressure corresponding to ambient temperature Charge should be checked to obtain 12 to 15 of sub cooling per system i e compressor circuits START UP PROCEDURE AND CHECKLIST Begin with power turned off at all disconnects 1 Turn therm...

Страница 13: ...etting for cooling and heating or automatic changeover for normal use 20 Be sure the Owner is instructed on the unit operation filter servicing correct thermostat operation etc REFRIGERATION PERFORMANCE CHECK Under normal summertime full load operating conditions superheat should be between 8 F and 12 F and sub cooling measured at the condenser outlet should be 15 F nominal A 25 F to 35 F temperat...

Страница 14: ...per to 30 60 and 90 respectively Accumulation of time for the timing period selected starts when the sensor closes ap proximately 31 F and when the wall thermostat calls for heat At the end of the timing period the unit s defrost cycle will be initiated provided the sensor remains closed When the sensor opens approximately 75 F the defrost cycle is terminated and the timing period is reset If the ...

Страница 15: ...that the homeowner inspect the unit before a seasonal start up The coils should be free of debris so adequate airflow is achieved The return and supply registers should be free of any obstructions The filters should be cleaned or replaced These few steps will help to keep the product up time to a maximum The Service section that follows should help in identifying problems if the unit does not oper...

Страница 16: ...se low discharge pressure resulting in low suction pressure and frost accumulation on the outdoor coil POOR TERMINATING SENSOR CONTACT The unit s defrost terminating sensor must make good ther mal contact with the outdoor coil tubing Poor contact may not terminate the unit s defrost cycle quickly enough to pre vent the unit from cutting out on high discharge pressure MALFUNCTIONING REVERSING VALVE...

Страница 17: ...SPEED TAP EXTERNAL STATIC PRESSURE ESP in w c STANDARD CFM AMPS WATTS RPM 0 10 1296 1 67 356 764 0 20 1245 1 60 334 830 0 30 1174 1 56 325 861 0 40 1103 1 52 316 891 0 50 1013 1 46 300 935 0 10 1502 2 10 456 836 0 20 1449 2 06 444 864 0 30 1396 2 02 432 891 0 40 1335 1 97 418 916 0 50 1273 1 91 404 940 0 60 1153 1 83 380 973 0 70 996 1 71 346 1017 0 20 1516 2 36 506 940 0 30 1454 2 31 496 960 0 40...

Страница 18: ... SPEED TAP EXTERNAL STATIC PRESSURE ESP in w c STANDARD CFM AMPS WATTS RPM 0 10 1622 2 54 539 809 0 20 1558 2 43 517 852 0 30 1494 2 32 495 895 0 40 1410 2 21 471 924 0 50 1326 2 10 447 953 0 10 1861 3 11 670 886 0 20 1733 2 78 606 918 0 30 1639 2 64 568 960 0 40 1564 2 51 542 984 0 50 1434 2 35 508 1017 0 60 1320 2 25 482 1039 0 70 1156 2 08 446 1067 0 10 1984 3 34 734 949 0 20 1883 3 18 694 977 ...

Страница 19: ...4 60 576 929 0 40 1947 4 68 588 957 0 50 1897 4 79 608 989 0 60 1857 4 87 620 1012 0 70 1763 4 99 640 1050 0 80 1741 5 06 650 1072 0 90 1669 5 19 668 1105 0 10 2137 4 95 634 913 0 20 2093 5 07 652 940 0 30 2095 5 19 670 962 0 40 2026 5 28 682 990 0 50 1980 5 40 698 1018 0 60 1961 5 49 720 1039 0 70 1914 5 58 732 1072 0 80 1845 5 70 742 1100 0 90 1766 5 69 740 1127 0 10 2299 5 70 742 942 0 20 2233 ...

Страница 20: ...5 0 20 2068 4 25 536 852 0 30 2029 4 37 552 885 0 40 1971 4 48 568 913 0 50 1911 4 61 586 950 0 60 1876 4 73 604 973 0 70 1821 4 86 622 1012 0 80 1792 4 91 630 1028 0 90 1740 5 03 648 1067 0 10 2233 4 76 608 863 0 20 2168 4 91 628 896 0 30 2125 5 02 640 924 0 40 2070 5 14 660 951 0 50 2050 5 27 678 979 0 60 1980 5 41 696 1012 0 70 1954 5 47 704 1034 0 80 1893 5 60 724 1067 0 90 1852 5 70 736 1089 ...

Страница 21: ...P CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 2579 1 01 2368 0 85 2175 0 691 1961 0 55 0 4 2513 1 05 2318 0 89 2089 0 73 1906 0 59 1666 0 44 0 6 2514 1 14 2276 0 94 2045 0 77 1797 0 60 1604 0 47 0 8 2261 1 01 2017 0 82 1760 0 63 1 0 1989 0 87 1730 0 68 1 2 1695 0 72 CPC H072 STANDARD BELT DRIVE DOWN SHOT CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 2771 1 27 2567 1 05 2421 0 88 2220 0 71 0 ...

Страница 22: ... H060 HIGH STATIC BELT DRIVE DOWN SHOT CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 6 2331 1 01 2072 0 80 0 8 2324 1 10 2059 0 87 1791 0 66 1 0 2350 1 21 2058 0 95 1774 0 72 1 2 2367 1 33 2086 1 06 1776 0 79 1 4 2404 1 45 2111 1 17 1805 0 89 1 6 2136 1 28 1835 0 99 1 8 1868 1 10 CPC H072 HIGH STATIC BELT DRIVE DOWN SHOT CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 6 2793 1 64 2603 1 39 2...

Страница 23: ...BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 2420 0 79 2198 0 64 0 4 2605 1 02 2358 0 84 2133 0 67 1874 0 52 0 6 2526 1 06 2300 0 88 2026 0 70 1806 0 55 0 8 2529 1 15 2252 0 93 1975 0 73 1670 0 54 1 0 2233 0 99 1943 0 78 1628 0 57 1 2 1907 0 83 1582 0 61 CPC H072 STANDARD BELT DRIVE HORIZONTAL CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 2784 1 30 2582 0 83 2411 0 79 0 4 2814 1 34 2620 1...

Страница 24: ...VE HORIZONTAL CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 6 2323 0 92 0 8 2315 1 00 2009 0 77 1 2308 1 09 1992 0 84 1666 0 60 1 2 2338 1 21 1992 0 92 1646 0 66 1 4 2359 1 32 2025 1 02 1648 0 72 1 6 2404 1 45 2056 1 13 1684 0 82 1 8 2088 1 24 1722 0 92 CPC H072 HIGH STATIC BELT DRIVE HORIZONTAL CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 6 2746 1 38 2515 1 12 0 8 2721 1 47 2494 1 21 226...

Страница 25: ...TIC 1 5 2 3 208 230 60 1 187 253 1 26 41 134 1 1 4 1 40 DD STD STATIC 1 0 7 6 DD STD STATIC 1 0 7 6 BD STD STATIC 1 0 3 8 460 60 3 414 506 1 7 76 52 0 1 1 4 0 80 BD STD STATIC 1 0 1 9 575 60 3 518 633 1 5 71 38 9 1 1 4 0 60 BD STD STATIC 1 5 2 3 208 230 60 3 187 253 1 19 123 1 1 3 1 92 BD STD STATIC 1 5 5 0 460 60 3 414 506 1 9 70 62 0 1 1 3 1 20 BD STD STATIC 1 5 2 5 575 60 3 518 633 1 7 4 50 0 1...

Страница 26: ...ted by the table above APPENDIX B ELECTRICAL DATA UNIT HEATER KIT MODEL NUMBER MINIMUM CFM EHK 10 1250 EHK 15 1250 EHK 10 1300 EHK 15 1400 EHK 18 1400 EHK 10 1700 EHK 15 1700 EHK 20 1800 EHK 10 2100 EHK 15 2100 EHK 20 2100 EHK 25 2100 MINIMUM AIR FLOW FOR ELECTRIC HEAT 5 TON 3 TON 4 TON 6 TON ...

Страница 27: ...cal discharge return and supply openings Install with insulation facing up using the longer screws provided in the literature package RETURN SUPPLY 12 17 7 3 8 11 25 6 1 4 4 7 8 DRAIN THRU CURB LOCATION EMBOSS FOR THRU THE BASE UTILITIES BOTTOM VIEW OF UNIT 8 3 16 5 7 8 19 7 16 27 3 8 47 1 2 4 1 2 7 1 2 SUPPLY RETURN 73 1 4 47 1 2 74 1 16 48 3 16 38 13 16 6 Ton 42 13 16 ...

Страница 28: ...28 Goodman Manufacturing Company L P 5151 Felipe Suite 500 Houston TX 77056 www goodmanmfg com www amana hac com 2010 2012 Goodman Manufacturing Company L P ...

Отзывы: