2

Important Safety Instructions

The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards.  It
is the owner’s and installer’s responsibility to read and com-
ply with all safety information and instructions accompanying
these symbols.  Failure to heed safety information increases
the risk of personal injury, property damage, and/or product
damage.

HIGH VOLTAGE!

 

Failure to do so may cause property damage,
personal injury or death.

Disconnect ALL power before servicing.
Multiple power sources may be present.

Installation and repair of this unit should be performed

by individuals meeting the requirements of an

“entry level technician”

 as specified by 

the Air-Conditioning, Heating and Refrigeration Institute
(AHRI).  Attempting to install or repair this unit without
such background may result in product damage, 
personal injury or death.

ONLY 

, at a  minimum,

This product is factory-shipped for use with 
208/240/1/60 electrical power supply. 
reconfigure this air handler to operate with any other 
power supply.

DO NOT 

To avoid property damage, personal injury or death 
due to electrical shock, this unit MUST have an 

 electrical ground. The 

electrical ground circuit may consist of an 
appropriately sized electrical wire connecting the 
ground lug in the unit control box to the building 
electrical service panel.
Other methods of grounding are permitted if performed 
in accordance with the National Electric Code 
(NEC)/American National Standards Institute 
(ANSI)/National Fire Protection Association (NFPA) 70 
and local/state codes. In Canada, electrical grounding 
is to be in accordance with the Canadian Electric Code  
(CSA) C22.1.

uninterrupted, unbroken

When installing or servicing this equipment, safety 
clothing, including hand and eye protection, is 
strongly recommended. If installing in an area that has 
special safety requirements (hard hats, etc.), observe 
these requirements.

 

 
 
 
 
 
 
 
 

 

 

 

CARBON MONOXIDE POISONING HAZARD  

-

 

 

Special Warning for Installation of Furnace or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas

Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions.  If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.

This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area.  Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.

CO can cause serious illness including permanent brain damage or death.

B10259-216

Important Note to the Owner regarding Product
Warranty

Your warranty certificate is supplied as a separate document
with the unit installed by your contractor. Read the limited
warranty certificate carefully to determine what is and is not
covered and keep the warranty certificate in a safe place. If
you are unable to locate the warranty certificate please con-
tact your installing contractor or contact customer service (877-
254-4729) to obtain a copy.

To receive the 10 Year Parts Limited Warranty, online regis-
tration must be completed within 60 days of installation. Online
registration is not required in California or Quebec. Complete
warranty details are available from your local dealer or, for
Goodman

®

 brand products, visit www.goodmanmfg.com and

for Amana

®

 brand products, visit www.amana-hac.com.

Do not connect to or use any device that is not design-
certified by Goodman for use with this unit. Serious 
property damage, personal injury, reduced unit 
performance and/or hazardous conditions may result 
from the use of such non-approved devices.

To prevent the risk of property damage, personal 
injury, or death, do not store combustible materials or 
use gasoline or other flammable liquids or vapors in 
the vicinity of this unit.

 

is a registered trademark of Maytag Corporation or its related companies and is used under

license to Goodman Company, L.P., Houston, TX.  All rights reserved.

Содержание ASPF Series

Страница 1: ...4 Electric Heat 4 HKR Installation 4 Electrical Supply Wire and MOP 4 Building Electrical Service Inspection 5 Wire Sizing 5 Maximum Overcurrent Protection MOP 5 Electrical Connections Supply Voltage...

Страница 2: ...ng Areas Carbon monoxide producing devices such as an automobile space heater gas water heater etc should not be operated in enclosed areas such as unventilated garages utility rooms or parking areas...

Страница 3: ...tion of your nearest distributor consult the white business pages the yellow page section of the local telephone book or contact CONSUMER AFFAIRS GOODMAN MANUFACTURING COMPANY L P 7401 SECURITY WAY HO...

Страница 4: ...19 28 37 41 2000 5 8 11 12 17 25 34 37 HEAT KIT NOMINAL kW CFM Table 2 230 1 60 Supply Voltage Temperature Rise Table F 3 5 6 8 10 15 20 21 600 17 27 34 39 800 13 20 25 30 40 1000 10 16 20 24 32 48 12...

Страница 5: ...314 235 188 157 134 118 110 Based on NEC 1996 Maximum Allowable Length in Feet to Limit Voltage Drop to 2 Minimum Circuit Ampacity MCA Wire Size AWG Table 6 Maximum Overcurrent Protection MOP Every i...

Страница 6: ...tched applications a flowrator piston change may be required See the Goodman piston kit chart or consult your local distributor for details regarding mix matched piston sizing If the mix match applica...

Страница 7: ...rain pan NOTE The filter provision is not applicable in THIS downflow application ACCESS PANEL RETURN AIR SIDE OF UNIT REAR CHANNEL BRACKET ZEE COIL SUPPORT BRACKET COIL RETAINING BRACKET TIE BRACKET...

Страница 8: ...the enclosure for external connections 1 Ensure drain pan hole is NOT obstructed 2 To prevent potential sweating and dripping on to finished space it may be necessary to insulate the condensate drain...

Страница 9: ...Delivery Table 9 shows the CFM speed tap settings for the ASPF Start Up Procedure Prior to start up ensure that all electrical connections are properly sized and tightened All panels must be in place...

Страница 10: ...owing composite wiring diagrams detail various con figurations in which the ASPF air handlers can be used Ex amples include single stage cooling and heat pump with single or two stage electric heating...

Страница 11: ...B YL BL CONDENSING UNIT 24V CONNECTION BL YL GR RD 18 GA 5 WIRES WITH COOLING 4 WIRES WITHOUT WH YL BR BR BR YL G C R HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW C W1 W2 Y2 Y1 O G R TB 1...

Страница 12: ...IT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE C W1 W2 Y2 Y1 O G R TB 18 GA 7 WIRE O Y C W2 R Y O W2 E RD GR BL OR YL YL BL OR WH BR WH BL WH WH RD BR RD WH GR YL OR OR RD OR NOTES 1 OUTDOOR THERMOSTAT...

Страница 13: ...OF CR RELAY TOAPPROPRIATE TAP AT TB 4 BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY 5 FUSE 3A 250V 3AG CARTRIDGE FUSE RELAY EVAPORATOR MOTOR TERMINALBOARD R EM TB BK RD BL YL BLUE BLACK RED YELLOW...

Страница 14: ...14 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 15: ...e airflow If cleaning of the outdoor coil becomes necessary hire a qualified servicer Inexperienced people could easily puncture the tubing in the coil Even a small hole in the tubing could eventually...

Страница 16: ...2 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com or www amana hac com NOTE SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITH...

Отзывы: