Goodman AMES960403BU AA Скачать руководство пользователя страница 6

SYSTEM OPERATION

6

Safety

Please adhere to the following warnings and cautions when 

installing, adjusting, altering, servicing, or operating the 

furnace.

T

O P

REVE

NT P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH D

UE

 TO 

IM

P

R

OP

ER

 

I

N

S

TALLAT

I

ON,

AD

JUS

T

ME

NT, ALT

ER

AT

I

ON, 

SERVI

C

E

 O

R

 

M

A

I

NT

E

NANC

E

RE

F

ER

 TO TH

IS

M

AN

U

AL. 

F

O

R

 ADD

I

T

I

ONAL A

SSIS

TANC

E

 O

R

 

I

NFO

RM

AT

I

ON, CON

SU

LT A

QU

AL

I

F

IE

I

N

S

TALL

ER

SERVI

C

E

 AG

E

NCY O

R

 TH

E

 GA

S

 

SU

PPL

IER

.

WARNING

WARNING

T

O P

REVE

NT PO

SSI

BL

E

 P

R

OP

ER

TY DA

M

AG

E

, P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH

D

UE

 TO 

E

L

E

CT

RI

CAL 

S

HOC

K

, TH

E

 F

UR

NAC

E

 

MUS

T B

E

 LOCAT

E

D TO P

R

OT

E

CT

TH

E

 

E

L

E

CT

RI

CAL CO

M

PON

E

NT

S

 F

R

O

M

 

W

AT

ER

.

Charge (ESD) Precautions
NOTE: 

Discharge your body’s static electricity before touching 

unit. An electrostatic discharge can adversely affect electrical 

components.
Use the following precautions during furnace installation 

and servicing to protect the integrated control module from 

damage. By putting the furnace, the control, and the person 

at the same electrostatic potential, these steps will help 

avoid exposing the integrated control module to electrostatic 

discharge. This procedure is applicable to both installed and 

uninstalled (ungrounded) furnaces.
1.  Disconnect all power to the furnace. Do not touch the 

integrated control module or any wire connected to the 

control prior to discharging your body’s electrostatic  

charge to ground.

2.  Firmly touch a clean, unpainted, metal surface of the 

furnace near the control. Any tools held in a  person’s 

hand during grounding will be discharged.

3.  Service integrated control module or connecting wiring 

following the discharge process in Step 2. Use caution 

not to recharge your body with static electricity; (i.e., do 

not move or shuffle your feet, do not touch ungrounded 

objects, etc.). If you come in contact with an ungrounded 

object, repeat Step 2 before touching control or wires.

4.  Discharge any static electricity from your body to ground 

before removing a new control from its container. Follow 

Steps 1 through 3 if installing the control on a furnace. 

Return any old or new controls to their containers before 

touching any ungrounded object.

Product Application

This product is designed for use as a residential home gas 

furnace. It is 

not

 designed or certified for use in mobile home, 

trailer, or recreational vehicle applications.

In the U.S.A., this furnace can be used in the following non-industrial 

commercial applications: Schools, Office buildings, Churches, Retail 

stores, Nursing homes, Hotels/motels, Common or office areas.  In 

all applications, the furnace must be installed per the installation 

instructions.

Goodman

®

 brand GMES96*U and Amana

®

  brand  AMES96*U  

furnaces are ETL certified.  All *MES96*U furnaces are built 

for use with Natural gas only & may not be converted for use 

with LP gas.
Goodman

®

 brand GMES96*U and  Amana

®

  brand AMES96*U  

high efficiency furnaces are dual certified. Dual certification 

means that the combustion air inlet pipe is optional and the 

furnace can be vented as a:
• 

  Non-direct vent (single pipe) central forced air furnace 

in which combustion air is taken from the installation 

area or from air ducted from the outside or,

• 

 Direct vent (dual pipe) central forced air furnace in 

which all combustion air supplied directly to the furnace 

burners through a special air intake system outlined in 

this manual and the installation instructions.

To ensure proper installation, operation and servicing, 

thoroughly read the installation and service manuals 

for  specifics  pertaining  to  the  installation,  servicing  and 

application of this product. 

WARNING

P

O

SSI

BL

E

 P

R

OP

ER

TY DA

M

AG

E

, P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH D

UE

 TO F

IRE

,

EX

PLO

SI

ON, 

SM

O

KE

S

OOT, COND

E

N

S

TA

I

ON, 

E

L

E

CT

RI

CAL 

S

HOC

K

 O

R

 CA

R

BON

M

ONO

XI

D

E

 

M

AY 

RESU

LT F

R

O

M

 

IM

P

R

OP

ER

 

I

N

S

TALLAT

I

ON, 

RE

PA

IR

, OP

ER

AT

I

ON,

O

R

 

M

A

I

NT

E

NANC

E

 OF TH

IS

 P

R

OD

U

CT.

WARNING

T

O P

REVE

NT P

R

OP

ER

TY DA

M

AG

E

, P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH D

UE

 TO F

IRE

,

DO NOT 

I

N

S

TALL TH

IS

 F

UR

NAC

E

 

I

N A 

M

OB

I

L

E

 HO

ME

, T

R

A

I

L

ER

, O

R

 

RE

C

RE

AT

I

ONAL

VE

H

I

CL

E

.

To ensure proper furnace operation, install, operate, maintain 

and service the furnace in accordance with the installation, 

operation and service instructions, all local building codes 

and ordinances. In their absence, follow the latest edition of 

the National Fuel Gas Code (NFPA 54/ANSI Z223.1), and/or 

CAN/CGA B149 Installation Codes, local plumbing or waste 

water codes, and other applicable codes.
A copy of the National Fuel Gas Code (NFPA 54/ANSI Z223.1) 

can be obtained from any of the following:
 

American National Standards Institute 

    25 West 43

rd

 Street, 4

th

 Floor

    New York, NY 10036

Содержание AMES960403BU AA

Страница 1: ...ced only by a qualified service technician who is familiar with the safety procedures required in the repair and who is equipped with the proper tools parts testing instruments and the appropriate ser...

Страница 2: ...arts testing in struments and the appropriate service manual REVIEWALL SERVICEINFORMATIONINTHEAPPROPRIATESERVICE MANUAL BEFORE BEGINNING REPAIRS OUTSIDE THE U S call 1 713 861 2500 Not a technical ass...

Страница 3: ...El mon xido de carbono puede causar enfermedades severas como da o cerebral permanente muerte Las emisiones de mon xido de carbono pueden circular a trav s del aparato cuando se opera en cualquier mo...

Страница 4: ...dman A Initial Release V GMC B 1st Revision Configuration M Upflow Horizontal Major Revision C Downflow Horizontal A Initial Release B 1st Revision Airflow C Variable Speed ComfortNet Nox E High Effic...

Страница 5: ...nless Steel tubular heat exchanger 115 volt silicon nitride igniter Left or right gas entry Line voltage EAC HUM terminals GMES96 U GMES960403BU AA GMES960603BU AA GMES960805CU AA Goodman Brand 96 Ult...

Страница 6: ...a residential home gas furnace It is not designed or certified for use in mobile home trailer or recreational vehicle applications In the U S A this furnace can be used in the following non industria...

Страница 7: ...LOSURE FAILURE TO FOLLOW THIS WARNING CAN RESULT IN PROPERTY DAMAGE EQUIPMENT DAMAGE PERSONAL INJURY OR DEATH Condensate Drain Lines and Drain Trap Acondensing gas furnace achieves its high level of e...

Страница 8: ...ply pressures must be maintained within the ranges specified below The supply pressure must be constant and available with all other household gas fired appliances operating The minimum gas supply pre...

Страница 9: ...ombustion analysis are required for all installations above 4500 ft Refer to Gas Supply Pressure Measurement section for instruction on how to properly measure and adjust manifold outlet pressure The...

Страница 10: ...le electronic air cleaner terminals EAC are energized with 115 volts whenever the circulator blower is energized NOTE Wire routing must not to interfere with circulator blower operation filter removal...

Страница 11: ...90 seconds and display the proper fault code Induced draft blower is energized for 30 second prepurge Igniter warm up begins after 30 second prepurge expires Gas valves open at end of igniter warm up...

Страница 12: ...ntric Vent Kits DCVK Application The DCVK 20 and DCVK 30 kit is designed to allow the terminations of a direct vent furnace to be concentrically vented through a wall or roof This kit allows a single...

Страница 13: ...DRAFT AND CIRCULATION BLOWERS The bearings in the induced draft blower and circulator blower motors are permanently lubricated by the manufacturer No further lubrication is required Check motor windin...

Страница 14: ...2 164 327 655 1636 37 97 195 486 12 75 150 300 600 1500 38 23 47 95 189 474 13 69 138 277 555 1385 39 92 185 462 14 64 129 257 514 1286 40 22 45 90 180 450 15 60 120 240 480 1200 41 176 439 16 56 113...

Страница 15: ...t As the external static pressure goes up the temperature rise will also increase Consult the proper tables for tempera ture rise limitation BTU HR Calculation Example The unit being tested takes 40 s...

Страница 16: ...SERVICING 16 GAS VALVE BURNER ASSEMBLY PRESSURE TRANSDUCER INTEGRATED CONTROL BOARD CONTROL TRANSFORMER PRESSURE SWITCHES VENT PIPE CONNECTION COMBUSTION AIR CONNECTION DRAFT INDUCER Component I D...

Страница 17: ...any wires must be replaced replace with AWM 105 C 2 64 thick insulation of the same gauge or its equivalent THERMOSTAT AND WIRING DISCONNECT ALL POWER BEFORE SERVICING WARNING 1 Remove the blower comp...

Страница 18: ...m High Speed Red wire connected to RED on the control board High Speed Orange wire connected to FAN on the control board Medium Speed Black Low Speed and Brown Medium Low Speed wires connected to PARK...

Страница 19: ...determine the air temperature rise Allow adequate time for thermometer readings to stabilize 4 Adjust temperature rise by adjusting the circulator blower speed Increase blower speed to reduce temperat...

Страница 20: ...test for continuity between each of the motor leads 4 Touch one probe of the ohmmeter to the motor frame ground and the other probe in turn to each lead If the windings do not test continuous or a re...

Страница 21: ...rner compartment door to gain access to the gas valve 2 Connect a calibrated water manometer or appropriate gas pressure gauge at either the gas valve inlet pressure tap or the gas piping drip leg as...

Страница 22: ...est screw inlet outlet pressure boss out one turn counterclockwise not more than one turn b Attach a hose and manometer to the outlet pressure outlet pressure boss c Turn ON the gas supply d Turn on p...

Страница 23: ...ED is blinking in AMBER then release The control will execute the following functions 1 Blower Heat Speed 15 seconds 2 Blower Cool Speed 15 seconds 3 Blower Fan Speed 15 seconds 4 Hot Surface Igniter...

Страница 24: ...minal 3 Place the unit into a heating cycle LINE VOLTAGE NOW PRESENT WARNING 4 As soon as flame is established a micro amp reading should be evident once proof of flame micro amp reading is establishe...

Страница 25: ...TROUBLESHOOTING 25...

Страница 26: ...TROUBLESHOOTING 26...

Страница 27: ...lash the Fault Code History up to 5 fault codes from newest to oldest Fault Code Clear Function When the SW1 button is pressed and held for an extended period more than 5 seconds less than 10 seconds...

Страница 28: ...IED REPLACEMENT PARTS MUST BE USED WHEN SERVICING 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS NOTES HI VOLTAGE FIELD HI VOLTAGE 115V LOW VOLTAGE FIELD LOW VOLTAGE 24V COLOR CODES RD RED GY G...

Страница 29: ...ntact us Amana Brand Products http www amana hac com about us contact us You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page GOODMAN BRAN...

Отзывы: