background image

12 www.goodmanmfg.com 

SS-GPCC

P

RODUCT

 S

PECIFICATIONS

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, speci

fi

 cations or designs without notice 

or without incurring obligations. © 2008-2009  •  Goodman Manufacturing Company, L.P.  •  Houston, Texas  •  Printed in the USA. 

W

IRING

 D

IAGRAM

 — PCC60***

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date schematic.

W

ARNING

H

igh 

V

oltage:  Disc

onnec

t all po

w

er bef

or

e ser

vicing or installing this unit

. Multiple po

w

er 

sour

ces ma

y be pr

esent

. F

ailur

e t

o do so ma

y cause pr

oper

ty damage

, personal injur

y

, or dea

th.

DI

S

CO

N

NE

C

T

 UN

IT

 P

O

W

E

R

W

H

EN

 C

H

AN

G

IN

G

 T

APS

CO

N

T

A

C

T

O

R (

CC)

YL

 YEL

L

O

W

OR

 OR

A

N

GE

VT

 VI

O

L

ET

GN

 GR

E

E

N

BK BL

ACK

BR BR

O

W

N

WH

 WH

IT

E

BU BL

UE

GY

 GR

A

Y

RD RED

CO

L

O

R CO

DE

LO

W

 V

O

LTA

G

E

L

O

W

 VO

L

T

AG

F

IEL

D

HI

 VO

L

T

AG

E

HI

 VO

L

T

AG

F

IE

L

D

20

283

201

 R

E

V

. 0

R

S

C

FA

N

CO

M

HE

R

M

CA

P

T1

T2

CO

M

P

OD

FA

N

CC

W

AR

N

IN

G

:  D

ISC

O

N

N

EC

T

 PO

W

ER

 BEF

O

R

E SER

VI

C

IN

G

.

U

SE C

O

PPER

 C

O

NDUCT

O

RS

 O

NL

Y

CO

M

P

RESSO

R

1

Ø

 W

IRI

NG

O.

D

.

FA

N

MOT

OR

CO

M

20

8

23

0

LO

A

D

LI

N

E

T

R

ANSF

O

R

M

E

R

C

S

R

F

IEL

D CO

NNECT

IO

N

208

/23

0 V

A

C

 1Ø

L1

GN

D

L2

AI

R

CI

RCUL

A

T

IO

N

BL

O

W

ER

(A

C

B

)

L1

20

8/

2

30 V

A

C

 1Ø

F

O

R P

R

O

PER 

O

PERAT

IO

O

N

 2

0

8

 VO

L

T

 T

H

E

F

O

L

L

O

W

ING

 CHANG

M

U

ST

 BE 

M

A

DE:

20

8 V

O

LT

 IN

S

T

A

L

LA

T

IO

N

M

O

VE 

RD6

 W

IRE F

R

O

M

 T

R

ANSF

O

R

M

E

R

230

 TE

R

M

IN

A

L

 TO

 208 

TE

R

M

IN

A

L

.

VT

20

RD

10

CO

NT

A

CT

O

R (

C

C)

PI

N

 1

PI

N

 2

PI

N

 3

PI

N

 4

PI

N

 5

PI

N

 6

PI

N

 7

PI

N

 8

PI

N

 9

GY

-7

0

TO

HEAT

ER

KI

T

BU-

3

4

RD-

1

3

BR-

2

1

YL

-2

7

CO

M

FA

N

H

E

R

M

CAPACI

T

O

R

YL

12

BK-

2

7

BR-

1

1

GN

D

L2

T2

L1

T1

W1

G

E

C

R

W

O

Y

24

V

CO

M

M

O

N

CA

P

L2

ST

A

R

T

CA

P

5

2

1

ST

A

R

T

RE

L

A

Y

VT

-7

RD-

6

BU-

9

BU-

9

RD-

2

7

23

0/

2

08

VT

-1

4

BU-

9

BU-

7

VT

-2

0

RD-

1

0

TO

HE

AT

ER

KIT

W2

USE C

O

PPER

CO

NDUCT

O

R

S

ON

L

Y

-

75°

C

 M

IN

HEAT

ER

KI

T

YL

/BK

L

O

W

 PRESSURE

SW

IT

CH (

L

PS)

RD-

2

7

RD

31

VT

16

RD

33

C2

C1

R3

O

AD

J

U

S

T

NO

RM

( )+

(-

)

T

EST

HE

A

T

A

B

C

D

CO

O

L

A

B

C

D

R2

EM

/W

2

W1

Y/Y

2

G

VT

-1

4

RD-

3

1

 BLOW

ER

INTER

FACE

C2

C1

R3

O

A

D

J

U

S

T

N

O

R

M

(

)+

(-

)

T

E

S

T

H

E

A

T

A

B

C

D

C

O

O

L

A

B

C

D

C

U

T

T

O

E

N

A

B

L

E

D

E

H

U

M

ID

IF

Y

R2

EM

/W2

W1

Y/Y

2

G

 BL

O

W

ER

IN

TE

R

FA

C

E

(C

O

O

L

)

A

B

C

D

17

00

17

17

17

34

17

50

(H

E

A

T

)

A

B

C

D

52

5(

7

.5

 K

W

)

70

0(

1

0 K

W

)

10

50

(15

 K

W

)

14

00

(20

 K

W

)

CF

M

AD

J

U

ST

NO

RM

(+

)

(-

)

TE

ST

CF

M

DE

T

A

IL

 2

RD

BK

GN

321

65

987

4

VI

E

W

 A-

A

AL

T

E

RNAT

E UNI

T

 PO

W

E

REF

RI

G

E

RAN

T

L

EADS 

M

AY BE 

USED W

IT

H

 EL

ECT

RI

C

HEAT

ER ACCESSO

RI

ES.

  SEE 

HEAT

E

R

ACCESSO

RY I

N

ST

AL

L

A

T

IO

N

 I

N

ST

RUCT

IO

N

S.

A

A

A

B

C

D

G

W

O

Y

R

C

T

E

RM

IN

AL

 BO

ARD

BU

7

BU-

3

4

RD-

1

3

VT

-1

6

G

W

O

Y

R

C

T

E

RM

IN

AL

 BO

ARD

SEE DET

AI

L

 2

AI

R

CI

RC

UL

A

T

IO

N

BL

O

W

ER

(A

C

B

)

EN

ABL

E

D

E

HU

M

IDI

F

Y

C

U

T TO

Содержание 10.3 EER

Страница 1: ...grommets for vibration isolation Two independent condenser coils for two stage operation High and low pressure controls on all systems Mild ambient switch Centrifugal fan for quiet and efficient opera...

Страница 2: ...s liquid temperature or pressure decreases Caution If control is used below 50 F accumulators should be added to the equipment to avoid slugging of the compressors ROOF CURB PGC 5 Full perimeter curb...

Страница 3: ...Fan Diameter 24 24 24 24 Outdoor Nominal CFM 5 500 5 500 6 400 6 400 Face Area ft 15 6 15 6 23 8 23 8 Rows Deep Fins per Inch 2 21 2 21 2 21 2 21 Tube Diameter Material Copper Copper Copper Copper El...

Страница 4: ...4 www goodmanmfg com SS GPCC PRODUCT SPECIFICATIONS DIMENSIONS Unit Size A Height B Supply Air C Return Air PCC090 X 36 12 176 16 PCC120 X 52 20 2513 16 X Electrical Designation...

Страница 5: ...l A B PCC090 X 6 7 PCC120 X 22 23 X Electrical Designation DIMENSIONS ELECTRICAL CONNECTIONS 1 Main power entrance location 2 Control wiring entrance location 3 Optional field installed internal disco...

Страница 6: ...8 4 90 6 68 2 8 4 90 6 81 8 8 4 93 5 93 5 70 WB 8 4 96 4 44 8 8 4 96 4 58 5 8 4 96 4 73 1 8 4 96 4 87 7 73 WB 8 5 101 3 35 1 8 5 101 3 49 7 8 5 101 3 64 3 8 6 101 3 78 9 100 61 WB 8 5 78 9 70 1 8 6 8...

Страница 7: ...9 11 7 126 6 126 6 64 WB 11 6 115 9 84 9 11 6 115 9 105 1 11 6 119 9 119 9 11 7 126 6 126 6 67 WB 11 7 122 6 72 7 11 7 122 6 93 0 11 7 122 6 111 8 11 7 126 6 126 6 70 WB 11 8 130 7 60 6 11 8 130 7 80...

Страница 8: ...RISE HEAT KIT AVAILABILITY Unit Size HKCB20 HKCB30 HKCB40 7 X X X 10 X X X X Heat Kit Available N A Heater Not Available Notes Maximum air temperature rise of 40 must not be exceeded See table for El...

Страница 9: ...SS GPCC www goodmanmfg com 9 PRODUCT SPECIFICATIONS FAN PERFORMANCE DATA...

Страница 10: ...MER HEATER ACCESSORIES SEE HEATER W C GY GRAY BK 5 2 ELECTRIC START ELECTRIC W1 HIGH 230 TERMINAL TO 208 TERMINAL MODEL E COMP VT VIOLET FAN RELAY SWITCH WH WHITE Y COOLING TAP MED LOW HIGH HIGH HIGH...

Страница 11: ...ER MED PHCB05C1 RELAY GN CAP RELAY COM L1 HORIZ LOW VOLTAGE C ACCESSORY INSTALLATION INSTRUCTIONS OR ORANGE TAP HEAT 1 LOW 22303201 REV 1 230 VOLT 4 FUSE 208 VOLT INSTALLATION LEADS MAY BE USED WITH E...

Страница 12: ...LATION BLOWER ACB L1 208 230 VAC 1 FOR PROPER OPERATION ON 208 VOLT THE FOLLOWING CHANGE MUST BE MADE 208 VOLT INSTALLATION MOVE RD6 WIRE FROM TRANSFORMER 230 TERMINAL TO 208 TERMINAL VT 20 RD 10 CONT...

Отзывы: