12 www.goodmanmfg.com
SS-GPCC
P
RODUCT
S
PECIFICATIONS
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, speci
fi
cations or designs without notice
or without incurring obligations. © 2008-2009 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
W
IRING
D
IAGRAM
— PCC60***
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date schematic.
W
ARNING
H
igh
V
oltage: Disc
onnec
t all po
w
er bef
or
e ser
vicing or installing this unit
. Multiple po
w
er
sour
ces ma
y be pr
esent
. F
ailur
e t
o do so ma
y cause pr
oper
ty damage
, personal injur
y
, or dea
th.
DI
S
CO
N
NE
C
T
UN
IT
P
O
W
E
R
W
H
EN
C
H
AN
G
IN
G
T
APS
CO
N
T
A
C
T
O
R (
CC)
YL
YEL
L
O
W
OR
OR
A
N
GE
VT
VI
O
L
ET
GN
GR
E
E
N
BK BL
ACK
BR BR
O
W
N
WH
WH
IT
E
BU BL
UE
GY
GR
A
Y
RD RED
CO
L
O
R CO
DE
LO
W
V
O
LTA
G
E
L
O
W
VO
L
T
AG
E
F
IEL
D
HI
VO
L
T
AG
E
HI
VO
L
T
AG
E
F
IE
L
D
20
283
201
R
E
V
. 0
R
S
C
FA
N
CO
M
HE
R
M
CA
P
T1
T2
CO
M
P
OD
FA
N
CC
W
AR
N
IN
G
: D
ISC
O
N
N
EC
T
PO
W
ER
BEF
O
R
E SER
VI
C
IN
G
.
U
SE C
O
PPER
C
O
NDUCT
O
RS
O
NL
Y
CO
M
P
RESSO
R
1
Ø
W
IRI
NG
O.
D
.
FA
N
MOT
OR
CO
M
20
8
23
0
LO
A
D
LI
N
E
T
R
ANSF
O
R
M
E
R
C
S
R
F
IEL
D CO
NNECT
IO
N
208
/23
0 V
A
C
1Ø
L1
GN
D
L2
AI
R
CI
RCUL
A
T
IO
N
BL
O
W
ER
(A
C
B
)
L1
20
8/
2
30 V
A
C
1Ø
F
O
R P
R
O
PER
O
PERAT
IO
N
O
N
2
0
8
VO
L
T
T
H
E
F
O
L
L
O
W
ING
CHANG
E
M
U
ST
BE
M
A
DE:
20
8 V
O
LT
IN
S
T
A
L
LA
T
IO
N
M
O
VE
RD6
W
IRE F
R
O
M
T
R
ANSF
O
R
M
E
R
230
TE
R
M
IN
A
L
TO
208
TE
R
M
IN
A
L
.
VT
20
RD
10
CO
NT
A
CT
O
R (
C
C)
PI
N
1
PI
N
2
PI
N
3
PI
N
4
PI
N
5
PI
N
6
PI
N
7
PI
N
8
PI
N
9
GY
-7
0
TO
HEAT
ER
KI
T
BU-
3
4
RD-
1
3
BR-
2
1
YL
-2
7
CO
M
FA
N
H
E
R
M
CAPACI
T
O
R
YL
12
BK-
2
7
BR-
1
1
GN
D
L2
T2
L1
T1
W1
G
E
C
R
W
O
Y
24
V
CO
M
M
O
N
CA
P
L2
ST
A
R
T
CA
P
5
2
1
ST
A
R
T
RE
L
A
Y
VT
-7
RD-
6
BU-
9
BU-
9
RD-
2
7
23
0/
2
08
VT
-1
4
BU-
9
BU-
7
VT
-2
0
RD-
1
0
TO
HE
AT
ER
KIT
W2
USE C
O
PPER
CO
NDUCT
O
R
S
ON
L
Y
-
75°
C
M
IN
HEAT
ER
KI
T
YL
/BK
L
O
W
PRESSURE
SW
IT
CH (
L
PS)
RD-
2
7
RD
31
VT
16
RD
33
C2
C1
R3
O
AD
J
U
S
T
NO
RM
( )+
(-
)
T
EST
HE
A
T
A
B
C
D
CO
O
L
A
B
C
D
R2
EM
/W
2
W1
Y/Y
2
G
VT
-1
4
RD-
3
1
BLOW
ER
INTER
FACE
C2
C1
R3
O
A
D
J
U
S
T
N
O
R
M
(
)+
(-
)
T
E
S
T
H
E
A
T
A
B
C
D
C
O
O
L
A
B
C
D
C
U
T
T
O
E
N
A
B
L
E
D
E
H
U
M
ID
IF
Y
R2
EM
/W2
W1
Y/Y
2
G
BL
O
W
ER
IN
TE
R
FA
C
E
(C
O
O
L
)
A
B
C
D
17
00
17
17
17
34
17
50
(H
E
A
T
)
A
B
C
D
52
5(
7
.5
K
W
)
70
0(
1
0 K
W
)
10
50
(15
K
W
)
14
00
(20
K
W
)
CF
M
AD
J
U
ST
NO
RM
(+
)
(-
)
TE
ST
CF
M
DE
T
A
IL
2
RD
BK
GN
321
65
987
4
VI
E
W
A-
A
AL
T
E
RNAT
E UNI
T
PO
W
E
R
REF
RI
G
E
RAN
T
L
EADS
M
AY BE
USED W
IT
H
EL
ECT
RI
C
HEAT
ER ACCESSO
RI
ES.
SEE
HEAT
E
R
ACCESSO
RY I
N
ST
AL
L
A
T
IO
N
I
N
ST
RUCT
IO
N
S.
A
A
A
B
C
D
G
W
O
Y
R
C
T
E
RM
IN
AL
BO
ARD
BU
7
BU-
3
4
RD-
1
3
VT
-1
6
G
W
O
Y
R
C
T
E
RM
IN
AL
BO
ARD
SEE DET
AI
L
2
AI
R
CI
RC
UL
A
T
IO
N
BL
O
W
ER
(A
C
B
)
EN
ABL
E
D
E
HU
M
IDI
F
Y
C
U
T TO