Declaration of Conformity

We

GOOD WILL INSTRUMENT CO., LTD.

No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan

GOOD WILL INSTRUMENT (SUZHOU) CO., LTD.

No.69 Lushan Road, Suzhou New District Jiangsu, China.

declare that the below mentioned product

PSS-2005, PSS-3203

are herewith confirmed to comply with the requirements set out in the Council Directive on
the Approximation of the Law of Member States relating to Electromagnetic Compatibility
(89/336/EEC, 93/68/EEC)and Low Voltage Equipment Directive(73/23/EEC, 93/68/EEC).
For the evaluation regarding the Electromagnetic Compatibility and Low Voltage
Equipment Directive, the following standards were applied:

 EMC

EN 61326-1:

 

Electrical equipment for measurement, control and laboratory use    –– EMC

requirements

 (1997+A1: 1998)

Conducted and Radiated Emissions
EN 55011: 1991+A1: 1997+A2: 1996

Electrostatic Discharge
EN 61000-4-2: 1995

Current Harmonic
EN 61000-3-2: 1995+A1: 1998+A2: 1998 +A14: 2000

Radiated Immunity
EN 61000-4-3: 1996

Voltage Fluctuation
EN 61000-3-3: 1995

Electrical Fast Transients
EN 61000-4-4: 1995

-------------------------

Surge Immunity
EN 61000-4-5: 1995

-------------------------

Conducted Susceptibility
EN 61000-4-6: 1996

-------------------------

Voltage Dips/ Interrupts
EN 61000-4-11: 1994

 Safety

Low Voltage Directive 73/23/EEC & amended by 93/68/EEC

IEC/EN 61010-1: 2001

    PSS-3203/2005 PROGRAMMABLE POWER SUPPLY

USER MANUAL

  1  

1. PRODUCT INTRODUCTION

1-1.Description

PSS-series Programmable Power Supply is controlled by Micro

Processor Unit (MPU) that can easily connect communication interface

RS-232 or GPIB to computer in order to satisfy users’ demand for

auto-testing and auto-control.

The voltage and current are completely controlled by a 12 bits D/A

Converter with higher resolution and accuracy. Also, the digitalization of

system makes a speedy, precise and convenient input of information

controlled by keyboard and wheel knob.

The adjustment of voltage/current is made by software calibration

without man-made error that will increase the preciseness of the

instrument.

The function of Over Voltage Protection (OVP) and Over Current

Protection (OCP) is set with software and detected with hardware to

achieve protected function precisely and speedily in order to secure users

from danger by using the instrument.

1-2.

 

Feature

1)

 

An overall digitalization of programmable interface with high

resolution.

2)

 

The 16

×2

 LCD Display.

3)

 

High stability and low draft.

Содержание PSS-2005

Страница 1: ...12 13 13 13 6 MAINTENANCE 6 1 Fuse Replacement 6 2 Line Voltage Conversion 6 3 Adjustment and Calibration 6 4 Cleaning 14 14 14 15 18 7 THE SYSTEM DIAGRAM AND DESCRIPTION 7 1 Block Diagram 7 2 The Ope...

Страница 2: ...loured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in doubt consult the instructions provided with the eq...

Страница 3: ...0 4 4 1995 Surge Immunity EN 61000 4 5 1995 Conducted Susceptibility EN 61000 4 6 1996 Voltage Dips Interrupts EN 61000 4 11 1994 Safety Low Voltage Directive 73 23 EEC amended by 93 68 EEC IEC EN 610...

Страница 4: ...0 21V 1 Voltage 3mV 5mV rating current 3 0A Load Effect Current 3mA 5mA rating current 3 0A Voltage 3mV Source Effect Current 3mA Voltage 10mV Current 1mA 2mA rating current 3 0A Resolution OVP 10mV V...

Страница 5: ...ng from the factory Upon receiving the instrument please unpack and inspect it to check if there is any damage caused during transportation If any sign of damage is found notify the bearer and or the...

Страница 6: ...32 to 104 F To operate the instrument exceeding this specific temperature range may cause damage to the circuits of instrument Do not use the instrument in a place where strong magnetic or electric f...

Страница 7: ...for value input or setting confirmation 8 F C The knob for switching over coarse and fine adjustment 9 MENU The category of function setting Output OVP OCP Contrast Buzzer Interface PS After switching...

Страница 8: ...RAMMABLE POWER SUPPLY USER MANUAL 11 Example If want to set the current as 1 234A first using the F C knob to switch the cursor to 1mA step and adjust the value to 34 then switch the cursor to 100mA s...

Страница 9: ...indow will be appeared then using the wheel knob to modify the value and press ENTER to complete the setting Note The system will detect the interface used at present automatically and switch the dete...

Страница 10: ...tage to another is done by change AC selects switch The rear panel identifies the line voltage to which the unit was factory set To convert to a different line voltage perform the following procedure...

Страница 11: ...e Max measured by the DMM with the knob and press ENTER During the current value input use the PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 17 F C button to switch over the input of 100mA range...

Страница 12: ...may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene toluene xylene acetone or similar solvents Do not use abrasive cleaners on any portion of the instrument PSS...

Страница 13: ...materials can use the Vr to make adequate adjustment PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 21 The operation in C C Mode is similar to that in C V Mode The MPU will send 2100 counts 2 1A...

Отзывы: