Good Will Instrument PSS-2005 Скачать руководство пользователя страница 2

    PSS-3203/2005 PROGRAMMABLE POWER SUPPLY

USER MANUAL

     

       

iii

FOR UNITED KINGDOM ONLY

NOTE: This lead/appliance must only be wired by competent persons

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT: The wires in this lead are coloured in accordance with

the following code:

Green/ Yellow: 

Earth

Blue:

Neutral

Brown:

Live (Phase)

As the colours of the wires in main leads may not correspond with the

colours marking identified in your plug/appliance, proceed as follows:

The wire which is coloured Green & Yellow must be connected to the

Earth terminal marked with the letter E or by the earth symbol 

or coloured Green or Green & Yellow.

The wire which is coloured Blue must be connected to the terminal

which is marked with the letter N or coloured Blue or Black.

The wire which is coloured Brown must be connected to the terminal

marked with the letter L or P or coloured Brown or Red.

If in doubt, consult the instructions provided with the equipment or

contact the supplier.

    PSS-3203/2005 PROGRAMMABLE POWER SUPPLY

USER MANUAL

     

       

iv

This cable/appliance should be protected by a suitably rated and

approved HBC mains fuse: refer to the rating information on the

equipment and/or user instructions for details. As a guide, cable of

0.75mm

2

 should be protected by a 3A or 5A fuse. Larger conductors

would normally require 13A types, depending on the connection

method used.

Any moulded mains connector that requires removal /replacement

must be destroyed by removal of any fuse & fuse carrier and disposed

of immediately, as a plug with bared wires is hazardous if a engaged

in live socket. Any re-wiring must be carried out in accordance with

the information detailed on this label.

Содержание PSS-2005

Страница 1: ...12 13 13 13 6 MAINTENANCE 6 1 Fuse Replacement 6 2 Line Voltage Conversion 6 3 Adjustment and Calibration 6 4 Cleaning 14 14 14 15 18 7 THE SYSTEM DIAGRAM AND DESCRIPTION 7 1 Block Diagram 7 2 The Ope...

Страница 2: ...loured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in doubt consult the instructions provided with the eq...

Страница 3: ...0 4 4 1995 Surge Immunity EN 61000 4 5 1995 Conducted Susceptibility EN 61000 4 6 1996 Voltage Dips Interrupts EN 61000 4 11 1994 Safety Low Voltage Directive 73 23 EEC amended by 93 68 EEC IEC EN 610...

Страница 4: ...0 21V 1 Voltage 3mV 5mV rating current 3 0A Load Effect Current 3mA 5mA rating current 3 0A Voltage 3mV Source Effect Current 3mA Voltage 10mV Current 1mA 2mA rating current 3 0A Resolution OVP 10mV V...

Страница 5: ...ng from the factory Upon receiving the instrument please unpack and inspect it to check if there is any damage caused during transportation If any sign of damage is found notify the bearer and or the...

Страница 6: ...32 to 104 F To operate the instrument exceeding this specific temperature range may cause damage to the circuits of instrument Do not use the instrument in a place where strong magnetic or electric f...

Страница 7: ...for value input or setting confirmation 8 F C The knob for switching over coarse and fine adjustment 9 MENU The category of function setting Output OVP OCP Contrast Buzzer Interface PS After switching...

Страница 8: ...RAMMABLE POWER SUPPLY USER MANUAL 11 Example If want to set the current as 1 234A first using the F C knob to switch the cursor to 1mA step and adjust the value to 34 then switch the cursor to 100mA s...

Страница 9: ...indow will be appeared then using the wheel knob to modify the value and press ENTER to complete the setting Note The system will detect the interface used at present automatically and switch the dete...

Страница 10: ...tage to another is done by change AC selects switch The rear panel identifies the line voltage to which the unit was factory set To convert to a different line voltage perform the following procedure...

Страница 11: ...e Max measured by the DMM with the knob and press ENTER During the current value input use the PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 17 F C button to switch over the input of 100mA range...

Страница 12: ...may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene toluene xylene acetone or similar solvents Do not use abrasive cleaners on any portion of the instrument PSS...

Страница 13: ...materials can use the Vr to make adequate adjustment PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 21 The operation in C C Mode is similar to that in C V Mode The MPU will send 2100 counts 2 1A...

Отзывы: