Installation For Round Surface Mount Electrical Boxes

Installation For Recessed Electrical Boxes

GND

FRON

T

For Recessed

Electrical Boxes

English

1A

1B

Pull supply wires out of the electrical box. Using machine screws (

AA

 or 

BB

), secure mounting strap (

FF

) to the electrical box. Ensure the side marked “FRONT” is

facing out. Remove protective paper from adhesive face of foam gasket (

GG

). Pull supply wires through the opening in gasket and adhere gasket to the mounting strap and outer 

edge of round surface electrical box.
Pull supply wires out of the electrical box. Using machine screws (

AA

 or 

BB

), secure mounting strap (

FF

) to the electrical box. Ensure the side marked “FRONT” is facing out.

x2

AA/BB

x2

AA/BB

FF x1

FF x1

GG x1

GND

FRON

T

GND

FRON

T

3

A

FF x1

EE x1

Silicone

3

B

AREA LIGHT SETTINGS:

 Decide if area light at lower brightness is to be activated at dusk. Locate right control knob and set to desired time the area light is on. Setting to “Dusk To 

Dawn” turns light on from sunset to sunrise.

SECURITY MOTION LIGHT SETTINGS: 

The motion sensor on this fixture has a built in Dusk-to-Dawn sensor that automatically disables the motion sensor during daylight hours 

regardless of motion detection. The additional 360° sensor detects motion up to 14 ft. below.

Test: 

The motion sensor must be tested prior to starting. To test fixture, restore power to fixture, locate middle control knob and set to “Test.” During test mode, the lights will come on 

for 40 seconds, regardless of motion detection or the time of day. The light will shut off automatically after 40 seconds. Leave the knob on “TEST” and test the sensitivity by crossing 

in the path of the sensor. The light will come on only if it senses movement. Once movement stops, it will turn off in 5 seconds. The test is now complete.

Timer: 

Once fixture is tested, set middle control knob to desired time the light stays on once motion is detected.

Range: 

Locate left control knob and set to desired range of motion detection. Rotating knob to “Max” increases the distance of the motion sensor up to 100 ft. 

NOTE

: A higher 

sensitivity level increases the chances of a false activation being triggered. For maximum range performance, allow the fixture to operate at any setting (with power) for at least

48 hours.

Manual Mode:

 To control the security light from inside the home, activate manual “ON” mode by toggling the wall light switch OFF and ON within 2 seconds. The security light will 

turn on and stay on for approximately 8 hours, or until the Dusk-to-Dawn sensor detects light in the morning. Once the Dusk-to-Dawn sensor detects light, the manual “ON” mode will 

automatically go back to its original settings of the AUTO motion sensor mode.

For Recessed

Electrical Boxes

2

Fixture must be properly grounded. Connect fixture ground wire to ground wire

in electrical box using wire nut 

(DD)

. These wires can be either green or bare

copper. Insert black supply lead into connector on black fixture wires and white

supply lead into connector on white fixture wires. Push excess wire into

electrical box.

NOTE

: If eave mounting the fixture, position the sensor head with the adjustment

controls and drain holes facing downward to prevent water damage.

3

A

3

B

Position fixture over the mounting strap. Secure long machine screw (

CC

through the center hole of the wall plate and mounting strap. 

NOTE

: Ensure 

gasket (

GG

) properly seals gap between wall plate and electrical box to prevent 

water seepage into electrical box. Restore power to the electrical box and 

ensure that the light is functioning properly. 

If the light is functioning properly, fit 

the silicone cap (

EE

) into the mounting screw opening to prevent water seepage 

into the housing.

For recessed electrical boxes, use silicone adhesive caulking (not included) to 

seal the gap between the wall plate and the mounting surface to prevent water 

seepage into the electrical enclosure.

240°

45°

The 240 degree coverage of the motion sensor is 

measured side to side. The sensor is more effective 

side-to-side, rather than motion coming straight at it 

(in-and-out). Adjust the motion sensor head so that 

it detects motion moving across the coverage area. 

The position of the sensor should not exceed 45° below horizontal. 

Do not aim the motion sensor at any water, bushes or plants that 

may move in the wind, pedestrian traffic, moving cars, etc., as this 

will trigger the motion sensor. 

NOTE

: If the sensor arm becomes 

loose, readjust the sensor head and tighten the joint screw on the 

sensor arm. 

Motion Sensor

2

DD x1

2

Range

2N1

30

SECURITY LIGHT

(High Beam)

AREA LIGHT

(Low Beam)

Feet

60

5

Max.

3hrs

5hrs

OFF

Dusk To Dawn

1

Minutes

5

Test

10

Operation Instructions

Timer

AREA LIGHT SETTINGS

(Lower Brightness)

Range

2N1

30

SECURITY LIGHT

(High Beam)

AREA LIGHT

(Low Beam)

Feet

60

5

Max.

3hrs

5hrs

OFF

Dusk To Dawn

1

Minutes

5

Test

10

SECURITY MOTION LIGHT SETTINGS

(Full Brightness)

Test

Range

2N1

SECURITY LIGHT

(High Beam)

AREA LIGHT

(Low Beam)

Feet

60

Max.

3hrs

5hrs

OFF

Dusk To Dawn

1

Minutes

5

Test

10

Timer

Range

2N1

30

SECURITY LIGHT

(High Beam)

AREA LIGHT

(Low Beam)

Feet

60

5

Max.

3hrs

5hrs

OFF

Dusk To Dawn

1

Minutes

5

Test

10

Range

Range

2N1

30

SECURITY LIGHT

(High Beam)

AREA LIGHT

(Low Beam)

Feet

60

5

Max.

3hrs

5hrs

OFF

Dusk To Dawn

1

Minutes

5

Test

10