34
EN
Automatic
In the
automatic
operating mode, the air conditioner automatically switches between the
ventilation
and
cooling
operating modes to maintain a temperature of 24 °C�
At a room temperature ≥ 24 °C, the air conditioner switches to
cooling
mode�
At a room temperature < 24 °C, the air conditioner switches to
ventilation
mode�
11.2 Switching the air conditioner on and off
1� Press the ON/OFF button (k) to switch on the air conditioner�
The status display (c) shows the room temperature and the air conditioner is in automatic mode.
2� Press the ON/OFF button (k) again to switch off the air conditioner�
11.3 Selecting an operating mode
• Press the MODE button (r) to change the operating mode�
The operating modes are cycled through in this order:
11.4 Setting the temperature
The temperature (set temperature) can be set in a range from 15 °C to 31 °C in steps of 1 °C� The air
conditioner does not have a heating function� If the set temperature is higher than the room temperatu-
re, the air conditioner will not work�
The temperature can only be set in
cooling
mode�
• Press the UP button (p) to increase the value by 1 °C�
• Press the DOWN button (o) to decrease the value by 1 °C�
The set temperature flashes in the status display (c).
After 5 seconds, the status display shows the current room temperature again.
11.5 Setting the fan speed
Two fan speeds are available: light fan and strong fan�
• Press the SPEED button to change the fan speed�
The fan speeds are cycled through in this order:
11.6 Setting the timer function
The air conditioner has a timer function� The timer function can be set at intervals from one hour to 24
hours�
1� Press the TIMER button (n) to activate the timer function�
The value for the timer flashes in the status display (c). The TIMER status indicator flashes yel-
low.
2� Press the UP button (p) to increase the value by 1 hour�
3� Press the DOWN button (o) to decrease the value by 1 hour�
4� When you have set the desired duration for the timer, wait about 5 seconds�
The status display switches to the current room temperature and the set timer is active. The
TIMER status indicator lights up yellow.
5� Press the TIMER button (n) again to deactivate the timer function�
11.7 Activating and deactivating the child lock
The air conditioner has a child lock� When the child lock is active, the function of all buttons on the con-
trol panel and the remote control is locked�
1� Press the LOCK button (s) for about 5 seconds to activate the child lock�
A signal tone sounds. The LOCK status indicator (l) lights up green.
2� Press the LOCK button (s) again for about 5 seconds to deactivate the child lock�