Non authorized translation
EC-type-examination Certificates without signature and official stamp shall not be valid. The certificates may be circulated only
without alteration. Extracts or alterations are subject to approval by the TÜV Hannover/Sachsen-Anhalt e.V.
Page 3 of
8
Schedule EC- Type- Examination Certificate No. TÜV 99 ATEX 1488
Any types
Alarm
current
circuits
(Terminal 5,6; 7,8)
Outputs:
Inputs:
Exclusive connection to a certificated intrinsically current
circuit with the following highest values each current circuit:
U
i
= 30 V
I
i
= 160 mA
P
i
= 850 mW
U
i
= 30 V
Effective internal inductivity
≤
40 µH
the effective internal capacity is negligibly small
All current circuits are safe gavanically separated up to a nominal voltage of 90 V to
each other. The input current circuit by the type D122.x.x.x.BM is internally connected
to the supply and signal circuit.
(16) Report No. 99/PX24090
(17) Special conditions for safe area
None
(18) Essential health and safety requirements
No additional