104
DOOR PANEL INSTALLATION
103
DOOR PANEL INSTALLATION
The connector CN7 Bus Nexa is located at the upper right side of the back of
the sound module.
Insert the connection cable that it is supplied with the module in the CN7
connector of the sound module and the other end of the connection cable
in the module with connector Bus Nexa.
The modules to connect with connector Bus Nexa are the next :
ð
N3403/AL: Con ect
m dul
n
to the o
e to add to the system with a graphic display module (coded
panel, see
manual)
TCode/CD Nexa
.
ð
N3301/AL: Con ect
n
to the module to add to the system with an access control module and
coded panel, (see
manual)
TCode/CD Nexa
.
ð
N3301A/AL: Co nect
n
to the module to add to the system with an alphabetic module, (see
TCode/CD Nexa
manual).
ð
EL3002: Con ect
(M xim
6
).
n
to power the illumination module
a
um EL3002 modules
ð
CD-NEXA/BT: Con ect
n
to the module to add to the system with a configuration RFC interface
(wireless device of 2,4 Ghz). Only for
and
modules
N3301
N3403
.
D
escription CN7 Bus Nexa connector.
C
on
.
nection with EL3002 illumination modules
Insert the Bus N
connection cable that it is
exa
supplied with the product, in the CN7
connector of the sound module and the
other end of the connection cable in any of
the three connectors placed at the bottom of
the EL3002 illumination module (maximum
6 EL3002 modules).
To connect to other illumination modules use
any of the two free connectors.
NOTE:
must be connected to power supply. The
Only the EL632/R5 or EL642/R5 sound module
EL3002 illumination module take the power through Bus Nexa connection cable (once the
Bus Nexa connection cable has been connected in the sound module).
The door panel illumination leds, will turn on during call and
communication progresses. Allowing us to see from apartment´s
monitor the person who has called. Only
/R5 sound
(
EL632
module .)
D
escrip
.
tion illumination leds
Visual indications on the door panel for people with impaired hearing:
- While calling: The led
will turn on during the call time process.
- During communication: The led will turn on during communication process.
- During door release: The led
will turn on during door release.
- End of communication: The led will turn off.
- In systems with several accesses doors in the building and one access door panel is in comunication:
The other accesses doors panels would have the led
of busy system turn on until end communication.
- While calling and the monitor is switch off: The led
will blink during 3 seconds.
- If a general door panel calls to a building with an inner door panel already in communication,
the led of the general door panel will blink during 3 seconds.