background image

.

P

ush buttons limit

.

P

ush buttons digital code

DOOR PANEL INSTALLATION

 

.

The codes shown in the shaded column correspond with the push buttons directly connected to
    the corresponding CN6 terminal of the EL500/V2PLUS circuit, or to the terminal 1 of its
    corresponding EL516 encoder

The number of push buttons that can be wired is limited to a maximum of 32 apartments, which
can be increased up to a maximum of 120 apartments (requires the use of the riser multiplexer
MC-V2Plus) and will be distributed in the EL516 encoders as shown in the table below:

Without EL516 circuits
With 1 EL516 circuit
With 2 EL516 circuits

          

:

          

:

          

:

          With 3 EL516 circuits:
          With 4 EL516 circuits:
          With 5 EL516 circuits:
          With 6 EL516 circuits:
          With 7 EL516 circuits:
          With 8 EL516 circuits:

8
7 + 15 = 22
6 + 15 + 15 = 36 (max. 32 without using multiplexer).
5 + 15 + 15 + 15 = 50
4 + 15 + 15 + 15 + 15 = 64
3 + 15 + 15 + 15 + 15 + 15 = 78
2 + 15 + 15 + 15 + 15 + 15 + 15 = 92
1 + 15 + 15 + 15 + 15 + 15 + 15 + 15 = 106
0 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 = 120

1

P2

1

P1

31

P4

61

P6

91

P8

16

P3

46

P5

76

P7

106

2

2

32

62

92

17

47

77

107

3

3

33

63

93

18

48

78

108

4

4

34

64

94

19

49

79

109

5

5

35

65

95

20

50

80

110

6

6

36

66

96

21

51

81

111

7

7

37

67

97

22

52

82

112

8

8

EL516 circuit terminals

E

L5

0

0

/V

2

P

LU

ci

rc

u

it 

te

rm

in

a

ls

38

68

98

23

53

83

113

9

9

39

69

99

24

54

84

114

10

10

40

70

100

25

55

85

115

11

11

41

71

101

26

56

86

116

12

12

42

72

102

27

57

87

117

13

13

43

73

103

28

58

88

118

14

14

44

74

104

29

59

89

119

15

15

45

75

105

30

60

90

120

82

.

P

ush buttons wiring

Plug the push buttons connection cable to the CN6 

connector of the EL500/V2PLUS microprocessor module; 
this cable has 10 conductors (P1 to P8, B and CP) for the 
connection of push buttons or EL516 encoders

The CP terminal must be connected to the push buttons 

common terminal and to the CP terminal of the push 
buttons encoder circuits

onnect B terminal to the B 

terminal of the encoders

Link the different push buttons common terminals of all the 

push buttons modules as shown in diagram

Link the push button inputs (P1…P8) to the push buttons 

and/or to the encoder circuits (P) as shown in the example

.

. C

.

  

A

 .

.

81

2

3

4

5

6

7

8

9

10

11

12

13

14

15

P

CP

1

B

To

 o

th

er

 e

n

co

d

er

s o

r p

u

sh

 b

u

tto

n

s

P4

P5

P6

P7

P8

B

CP

E

L-

5

1

6

 m

o

d

u

le

 te

rm

in

a

ls

CP

P8

B

P7

P1

P6

P2

P5

P3

P4

CP: Black
B:

Red

P1: Green
P2: Orange
P3: Blue

P4: Violet
P5: Yellow
P6: White
P7: Brown
P8: Grey

Colours codes

A

Top view 

DOOR PANEL INSTALLATION

REMEMBER:

 

    

).

    Up to 8 EL516 encoders (requires the use of the multiplexer 

MC-V2Plus)

, can be used to

    increase the number of push buttons (apartments) to 120 if the installation uses distributors
    and 64 if it does not (daisy chain).

The number of EL516 encoders which can be used is limited to 2, given that the

maximum number of push buttons (apartments) is 32 if the installation uses distributors, or 

    16 if it does not (daisy chain

REMEMBER:

 The maximum number of apartments is 32, but this can be increased to 120

    (requires the use of the multiplexer 

MC-V2Plus

).

   

Содержание V2PLUS

Страница 1: ...V2PLUS Video door entry system with unpolarised 2 wire installation Instructions manual TV2PLUS ML rev 0210...

Страница 2: ...ing Final adjustments Closing the door panel Power supply installation Lock release installation Platea V2Plus monitor Function push buttons Identification label 87 88 89 90 T 7822VD Description 91 91...

Страница 3: ...t call tones which identify the call procedure door panel or apartment door wInput for external door bell push button being necessary the use of digital converter CD V2Plus Up to 120 apartments and 12...

Страница 4: ...sh buttons module CE embedding boxes 6xx Sound module EL530 EL531 EL540 on video systems with color camera on audio systems on video systems with b w camera Microprocessor circuit 75 on audio and vide...

Страница 5: ...s service life it is recommended to take additional precautions visors covered areas To obtain a quality image on video door entry systems avoid direct incidence from light sources sun street lights 1...

Страница 6: ...el modules A Insert the header DOWN marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notch...

Страница 7: ...he top of the embedding box Insert the circuit in the top flanges of the embedding box 1 Push in the circuit in the bottom flanges 2 by pressing the pcb board To assemble the EL516 encoder screw the t...

Страница 8: ...ssed through the header clips as shown For example if the hinges are placed on both clips of the lower header the door panel will open downwards if they are placed on the right clips of both headers t...

Страница 9: ...h buttons modules The common terminal of the push buttons contained in a module are linked from factory This wire must be connected to the CP terminal of the EL500 V2PLUS microprocessor module and to...

Страница 10: ...nect B terminal to the B terminal of the encoders Link the different push buttons common terminals of all the push buttons modules as shown in diagram Link the push button inputs P1 P8 to the push but...

Страница 11: ...5 15 15 15 15 106 0 15 15 15 15 15 15 15 15 120 1 P2 1 P1 31 P4 61 P6 91 P8 16 P3 46 P5 76 P7 106 2 2 32 62 92 17 47 77 107 3 3 33 63 93 18 48 78 108 4 4 34 64 94 19 49 79 109 5 5 35 65 95 20 50 80 11...

Страница 12: ...ach backbone must only have one door panel or CD V2Plus converter configured as the master DOOR PANEL INSTALLATION Set to ON the switch number 2 for monitor or telephones programming Once the programm...

Страница 13: ...audio volume isn t correct proceed with the necessary adjustments as shown The telecamera has a pan and tilt mechanism If the orientation is not adequate then correct its position In case of low light...

Страница 14: ...s Fix the with the specified screws power supply The power supply can be installed on a DIN 46277 guide simply pressing it To disassemble the power supply from the DIN guide use a plain screwdriver to...

Страница 15: ...ast control colour control in colour monitors Brightness control depending on the model Inoperative push buttons Cord A Sw2 Dip switch Cable slot a g h b e k m l n d j c i CODIGO CODE SLAVE MASTER INT...

Страница 16: ...monitor no function no function push button code see page no function MASTER m SLAVE 2 INTER A1 CODE 82 STAIR End of line and amplifying the video signal The Sw2 configuration dip switch is located o...

Страница 17: ...ttachment hooks Vertical wiring input Attachment clip Central wiring input Installation terminals Digital communication bus input to monitor Digital communication bus output to additional monitor tele...

Страница 18: ...ust be 5cm Place the monitor at right angles to the connection block and align the attaching holes of the monitor with the attachment hooks of the connection block as it is shown on the drawing Lock o...

Страница 19: ...p the monitor s handset To show that the system is ready for programming the door panel and the monitor s handset will reproduce tones and an image will appear on the monitor Audio and video communica...

Страница 20: ...dless of the position of the handset activate the PA and PB voltage free contacts with the JP1 jumper inserted see page 96 or activate the SAR 2plus unit if the JP2 jumper is inserted see page 96 this...

Страница 21: ...s lose the telephone as shown on the picture Once the telephone is closed connect the handset using the telephone cord and put it on the cradle Avoid placing the telephone near sources of heat in dust...

Страница 22: ...lel unit be it a monitor or telephone it must be configured as slave Make a call to check that the telephone has been successfully programmed Repeat these steps to program the rest of telephones Once...

Страница 23: ...rs and the telephones incorporate as standards the call reception from the door bell push button This feature spares the use of a bell by placing a push button between the HZ monitor or telephone term...

Страница 24: ...phones or call repeaters must never exceed three units Platea V2Plus BUS IN PA PB BUS OUT HZ BUS HZ PA S HZ PB S T 7822VD Platea V2Plus BUS IN PA PB BUS OUT HZ Platea V2Plus BUS IN PA PB BUS OUT HZ Ad...

Страница 25: ...lues install a SAR 12 24 relay and TF 104 transformer as shown in the diagram PA and PB 40mA f Opening an additional door PRI SEC TF 104 Main Platea V2Plus BUS IN PA PB BUS OUT HZ JP1 JP2 JP1 JP2 BUS...

Страница 26: ...AGRAMS 97 C onfiguring the end of line in the last monitor BUS IN PA PB BUS OUT HZ Platea V2Plus BUS IN PA PB BUS OUT HZ Platea V2Plus Sw2 Sw2 SEC PRI 0 110 230 FA V2PLUS Main Master door panel CV1 12...

Страница 27: ...Door panel Monitor P S Door panel For greater distances contact our technical support department BUS D REMEMBER The total number of daisy chain elements in the installation monitors or telephones mus...

Страница 28: ...s End of line BUS IN PA PB BUS OUT HZ BUS BUS D Platea V2Plus End of line R 120W Insert a 120 ohm end of line resistor in the last distributor D1L V2Plus Sw2 Sw2 Configuring the end of line in the las...

Страница 29: ...nits Sections chart RAP 2150 Terminal SECTIONS CHART 100m Door panel Monitor P S Door panel For greater distances contact our technical support department BUS D 50m Door panel CV 50m 2 5mm 0 5mm IMPOR...

Страница 30: ...lus BUS IN PA PB BUS OUT HZ BUS D2 D1 BUS D4 D3 End of line BUS D2 D1 BUS D4 BUS IN PA PB BUS OUT HZ Platea V2Plus BUS IN PA PB BUS OUT HZ R 120W D4L V2Plus Configuring the end of line in the last mon...

Страница 31: ...its IMPORTANT In the output to the monitor telephone of a distributor cannot be connected another distributor Sections chart RAP 2150 Terminal SECTIONS CHART 100m Door panel Monitor P S Door panel For...

Страница 32: ...120W D4L V2Plus INSTALLATION DIAGRAMS 103 BUS IN PA PB BUS OUT HZ BUS IN PA PB BUS OUT HZ Platea V2Plus Sw2 BUS IN PA PB BUS OUT HZ Platea V2Plus Sw2 Configuring the end of line in the last monitor P...

Страница 33: ...istributor the total number of elements monitors or telephones distributed over all 4 outputs of the distributor must never exceed 32 units while one single output must never exceed 16 units 104 Maste...

Страница 34: ...n the last distributor D4L V2Plus BUS IN PA PB BUS OUT HZ BUS D2 D1 BUS D4 D3 End of line BUS D2 D1 BUS D4 BUS IN PA PB BUS OUT HZ Platea V2Plus BUS IN PA PB BUS OUT HZ R 120W D4L V2Plus Configuring t...

Страница 35: ...l For greater distances contact our technical support department BUS D 50m Door panel CV 50m 2 5mm CV1 CV2 1mm IMPORTANT In the output to the monitor telephone of a distributor cannot be connected ano...

Страница 36: ...S itself or between the BUS and any other terminal Door open function don t work Remember that this function is only available during call and communication progresses Create a short circuit between t...

Отзывы: