background image

6

TEKNA PLUS SE MONITOR

The monitor features an RJ-45 connector for installation with a UTP

cable. It is located on the left-hand side of the back of the monitor.
It enables connection of the system's main communication wires

(+, -, A, D, Vp y Mp)

.

in twisted-pair installations

RJ-45 connector (cable type: T568B)

Male connector

Female connector

PA R 2

I

PA R 1

I

PA R 4

I

PA R 3

I

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Ethernet cable Golmar connection

White + Orange

GND (Audio)

Audio

GND (Dat )

a

+18V

+18V

Data

Vp

White + Brown

Mp

RJ-45 equivalence table

Description of the RJ-45 connector (installation with UTP cable):

Pin

1

2

3

4

5

6

7

8

Orange

White + Green

Blue

White + Blue

Green

Brown

Locate the CN4 connector at the back of the monitor.
To insert the EL562 module, remove the jumper that is in the connector.

NOTE:

In this type of installation, set the SW1-3 DIP switches on the sound module of the

door panel to ON, see instruction manual

(page 13), or the SW1-3 DIP

T632/Plus ML

switches on the EL500SE microprocessor to ON, see manual

(page 7). The

T5000 ML

door panel of the SV801SE GRF kit does not require modification.
Use the specific wiring diagram.

The end of line jumper is located on the CN4 connector at the back of the monitor.
In the case of twisted pair installations, the end of line jumper is located in the EL562

module (see next section).

Do not remove the jumper if the video cable ends in the monitor. Remove the jumper if the

video cable continues after the monitor.

DESCRIPTION OF THE MONITOR

MONITOR ADJUSTMENTS

Handling of the end of line jumper:

EL562 module for video door entry system installations with twisted pair cable:

Содержание Tekna Plus SE

Страница 1: ...Code 50123594 T EN TEKNA PLUS SE REV 0 1 2 6 TEKNA PLUS SE MONITOR USER MANUAL TECHNOLOGY...

Страница 2: ...een the door panel power supply distributors and monitors Always follow the instructions contained in this manual Introduc n 2 tio Contents 2 Safety precautions 2 Characteristics 3 System operation 3...

Страница 3: ...ior door panel of the building being called and other possible general entrance door panels automatically disconnect If another visitor attempts to call from either a busy interior door panel a number...

Страница 4: ...installation fill in the label with the relevant information MASTER main monitor SLAVE secondary monitor INTER secondary monitor with intercom function A1 monitor connected to an auxiliary device COD...

Страница 5: ...l mode is only available with theTekna Plus SE monitor This only functions if no call or communication is in progress Regardless of the position of the handset the auxiliary device is activated With t...

Страница 6: ...monitor To insert the EL562 module remove the jumper that is in the connector NOTE In this type of installation set the SW1 3 DIP switches on the sound module of the door panel to ON see instruction m...

Страница 7: ...T SA AP 2C VP MP Malla Shield A1 PLUS A D Vin Vout Malla Shield HZ SA 2C A1 VP MP MP Malla Shield VP a x6 Holes for fixing to wall b x2 Monitor fixing clips c Vertical wiring entry d Fixing clip e Cen...

Страница 8: ...5cm Place the monitor at right angles to the wall mount connection block and align the holes on its base with the fixing clips of the connection block as shown in the drawing Close the monitor like a...

Страница 9: ...tant To perform this programming the monitor s SW2 DIP switches should be set to OFF Switch off the monitor to be programmed Once switched off press the door release push button While keeping the door...

Страница 10: ...amming switch to OFF If this is not done the door panel will emit tones to indicate that the system is still in programming mode 1 2 3 4 5 6 7 8 9 10 Factory setting DIP3 to DIP10 To set the monitor a...

Страница 11: ...n is reached the following press returns the user to the first selection and 1 blink of the programming LED carousel mode Changing the ringtone melody Then select the melody for the ringtone selected...

Страница 12: ...evice activation A1 call to s second camera lave porter s exchange activation 2C and intercom When the final selection is reached the following press returns the user to the first selection and 1 blin...

Страница 13: ...s indicated with blinks 1 to 4 blinks of the programming LED and in the following order 60 90 120 and 150 seconds When the final selection is reached the following press returns the user to the first...

Страница 14: ...on for 3 seconds and the programming LED will turn off When exiting advanced programming mode the monitor will turn off Press button for 3 seconds to turn the monitor back on After any resetting of th...

Страница 15: ...220 V ac 1 8A max SAR 12 24 F N IN IN NC NA C The neutral of the lighting power supply is arranged serially through the contacts of the SAR 12 24 relay and the maximum consumption of the element to be...

Страница 16: ...es to call slave 2 4 times to call slave 3 and 5 times to call slave 4 This selective intercom call mode is only available with the Tekna Plus SE monitor This only functions if no call or communicatio...

Страница 17: ...tures as standard the ability to receive calls from the apartment front door This feature precludes the need to use the bell by positioning a switch between terminals HZ and of the monitor The rington...

Страница 18: ...in Vout Vout CN4 CN4 A _ D Mesh Vin Vout CN4 A _ D Mesh Vin Vout CN4 E E D1 D1 D2 D2 D4L PLUS D4L PLUS JP1 JP1 S S SW1 SW2 M Master M D Mesh Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5...

Страница 19: ..._ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 JP1 A A D D CT Vpi Vd1 Mpi Md1 _ _ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _...

Страница 20: ...olmar se reserva el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior no...

Отзывы: