background image

CHARACTERISTICS

-

Monitor for Plus / Uno installation.

-

.

3.5

TFT colour screen

-

.

Monitor with 3 common wires plus coaxial cable

-

Monitor with 4 common wires plus twisted pair.

-

Monitor with UTP cabling plus RJ-45 connector.

-

Function and advanced programming buttons (to customise the monitor's functions).

-

Completely private conversation and image.

-

.

Auto switch-on function

-

.

Auto spy function without occupying a channel

-

Doctor mode function ( automatic door opening , see p. 11).

- I

.

ntercom between two devices in the same apartment

-

.

Input for calls from the apartment front door

-

Call volume control (minimum, medium and maximum).

-

Input for outside door release push button.

-

Output to auxiliary call repeater.

-

Call to

and s

.

master

lave porter's exchange

-

.

Panic call to porter's exchange

-

.

Different ringtones to identify call origin: Door panel,

, intercom and interior door of the apartment

porter's exchange

-

Activation of two auxiliary functions: second camera, courtesy lights, etc.

-

.

Adjustment of brightness and colour

-

.

DIP switches for setting the monitor address, call code and master/slave (quick programming mode)

-

.

Door release push button

-

.

Monitor status LED

-

.

Programming LED

SYSTEM OPERATION

3

-

To make a call, the visitor presses the button for the apartment, a number of audible tones indicate that the call is being

made and LED on the door panel illuminates. At this moment, the apartment's monitor (telephone) receives the call.
If the visitor presses the button for another apartment by mistake, the call can be cancelled by pressing the button for
the correct apartment.

-

In systems with several access doors, the other door panel(s) automatically disconnect. If another visitor attempts to

call, a number of telephone tones will indicate that the channel is busy and LED

on the door panel will illuminate.

-

General entrance door panels (EL501 mode): If the call is being made from the general entrance door panel, the

interior door panel of the building being called and other possible general entrance door panels automatically

disconnect. If another visitor attempts to call from either a busy interior door panel, a number of telephone tones will

indicate that the channel is busy and LED of the door panel will illuminate, or from another general entrance door

panel, a number of telephone tones will indicate that the channel is busy and LED of the general entrance door panel

will blink for 3 seconds. The door panels of the other interior buildings will remain free to be used.

-

General entrance door panels (EL501 mode): If the call is made from an interior door panel, the other interior door

panels will remain free to be used. It is only possible to make calls to interior buildings from the general entrance door

panels when their door panels are not in use. If an attempt is made to make a call to a busy interior door panel, a

number of telephone tones will indicate that the channel is busy and LED

of the general entrance door panel will

blink for 3 seconds.

-

The call lasts for 45 seconds, during which time an image appears on the apartment's monitors for 2 seconds after the

call is received without the visitor knowing, and the status LED on the master monitor will illuminate (green). If the call

is not answered within 45 seconds, the master monitor's status LED will illuminate (red), LED

on the door panel will

turn off and the channel will be free.

-

To establish communication, lift the handset of the monitor (telephone), and the monitor's status LED (green) and the

door panel's LED will illuminate

.

-

The communication will last for one and a half minutes or until the handset is replaced. After the communication, the

monitor's status LED will illuminate (red), the door panel's LED will turn off and the channel will be free.

-

To open the door, press the door release push button during the call or communication processes: one press will

activate the door release for 3 seconds and LED will also illuminate for 3 seconds.

-

Descriptions of the function buttons can be found on page 5.

TEKNA PLUS SE MONITOR

Содержание Tekna Plus SE

Страница 1: ...Code 50123594 T EN TEKNA PLUS SE REV 0 1 2 6 TEKNA PLUS SE MONITOR USER MANUAL TECHNOLOGY...

Страница 2: ...een the door panel power supply distributors and monitors Always follow the instructions contained in this manual Introduc n 2 tio Contents 2 Safety precautions 2 Characteristics 3 System operation 3...

Страница 3: ...ior door panel of the building being called and other possible general entrance door panels automatically disconnect If another visitor attempts to call from either a busy interior door panel a number...

Страница 4: ...installation fill in the label with the relevant information MASTER main monitor SLAVE secondary monitor INTER secondary monitor with intercom function A1 monitor connected to an auxiliary device COD...

Страница 5: ...l mode is only available with theTekna Plus SE monitor This only functions if no call or communication is in progress Regardless of the position of the handset the auxiliary device is activated With t...

Страница 6: ...monitor To insert the EL562 module remove the jumper that is in the connector NOTE In this type of installation set the SW1 3 DIP switches on the sound module of the door panel to ON see instruction m...

Страница 7: ...T SA AP 2C VP MP Malla Shield A1 PLUS A D Vin Vout Malla Shield HZ SA 2C A1 VP MP MP Malla Shield VP a x6 Holes for fixing to wall b x2 Monitor fixing clips c Vertical wiring entry d Fixing clip e Cen...

Страница 8: ...5cm Place the monitor at right angles to the wall mount connection block and align the holes on its base with the fixing clips of the connection block as shown in the drawing Close the monitor like a...

Страница 9: ...tant To perform this programming the monitor s SW2 DIP switches should be set to OFF Switch off the monitor to be programmed Once switched off press the door release push button While keeping the door...

Страница 10: ...amming switch to OFF If this is not done the door panel will emit tones to indicate that the system is still in programming mode 1 2 3 4 5 6 7 8 9 10 Factory setting DIP3 to DIP10 To set the monitor a...

Страница 11: ...n is reached the following press returns the user to the first selection and 1 blink of the programming LED carousel mode Changing the ringtone melody Then select the melody for the ringtone selected...

Страница 12: ...evice activation A1 call to s second camera lave porter s exchange activation 2C and intercom When the final selection is reached the following press returns the user to the first selection and 1 blin...

Страница 13: ...s indicated with blinks 1 to 4 blinks of the programming LED and in the following order 60 90 120 and 150 seconds When the final selection is reached the following press returns the user to the first...

Страница 14: ...on for 3 seconds and the programming LED will turn off When exiting advanced programming mode the monitor will turn off Press button for 3 seconds to turn the monitor back on After any resetting of th...

Страница 15: ...220 V ac 1 8A max SAR 12 24 F N IN IN NC NA C The neutral of the lighting power supply is arranged serially through the contacts of the SAR 12 24 relay and the maximum consumption of the element to be...

Страница 16: ...es to call slave 2 4 times to call slave 3 and 5 times to call slave 4 This selective intercom call mode is only available with the Tekna Plus SE monitor This only functions if no call or communicatio...

Страница 17: ...tures as standard the ability to receive calls from the apartment front door This feature precludes the need to use the bell by positioning a switch between terminals HZ and of the monitor The rington...

Страница 18: ...in Vout Vout CN4 CN4 A _ D Mesh Vin Vout CN4 A _ D Mesh Vin Vout CN4 E E D1 D1 D2 D2 D4L PLUS D4L PLUS JP1 JP1 S S SW1 SW2 M Master M D Mesh Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5...

Страница 19: ..._ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 JP1 A A D D CT Vpi Vd1 Mpi Md1 _ _ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _...

Страница 20: ...olmar se reserva el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior no...