background image

DESCRIPTION OF THE TERMINAL

5

Function buttons:

In advanced programming mode (see p. 10), the default functions of function buttons

and

can be changed with

one of the following functions at the same time and per button:

-

:

Function button

Activation of auxiliary device 'A1,' call to secondary guard unit or

auto switch-on.

(1)

-

:

Function button

(1)

Activation of auxiliary device 'A1,' call to secondary guard unit, auto switch-on or intercom.

Start/stop communication button.
With the terminal in standby:

A short 1-second press activates the terminal in function mode (for 5 seconds).
A long 3-second press turns off the terminal. With the terminal turned off, one short
1-second press turns on the terminal (over the next 45 seconds, no operation can be
performed in 'function mode').

In function mode:

A long 3-second press turns off the terminal. With the terminal turned off, one short 1-second press turns
on the terminal (over the next 45 seconds, no operation can be performed in 'function mode').

During a communication process:

The talk/listen function is activated.

With the terminal in standby:

One long 3-second press activates 'ringtone volume mode', with a tone indicating the current volume
selected. Then each long 3-second press (before 5 seconds elapse) selects a ringtone volume level and
so on (in carousel mode) with the following selections (maximum, minimum and no volume 'night mode'.
Note: The 'night mode' status LED blinks red . During a call process, the terminal will emit a ringtone and

)

exit volume mode.
Regardless of the volume selected, the 'apartment interior door call' ringtone will always sound at
maximum volume.

In function mode:

A short 1-second press activates the auto switch-on function, enabling audio communication with door
panels that have this function activated to be established. This only functions if no communication is in
progress.

Auxiliary device 'A1' is activated at any time (regardless of whether the terminal is in standby or function, call,

communication or intercom mode).

With the terminal in standby:

A short 1-second press makes a panic call to the units configured to receive such calls.

In function mode:

A short 1-second press makes a normal call to the main unit.

During call reception and communication processes:

A short 1-second press activates the lock release for 3 seconds.

( )

*

(1)

Factory setting

( )

*

( )

*

NHEA PLUS SE HANDS-FREE AUDIO TERMINAL

Call volume control:

The terminal has a call volume

control with maximum and
minimum volume settings.

Audio volume control:

The terminal has a communication

audio volume control with maximum
and minimum volume settings.

MAX

+

+

-

Содержание NHEA PLUS SE TERMINAL

Страница 1: ...Code 50123372 TNHEA EN PLUS SE REV 0219 NHEA PLUS SE TERMINAL USER MANUAL PLUS DIGITAL SYSTEM...

Страница 2: ...he mains check the connections between the door panel power supply and terminals Always follow the instructions contained in this manual Introduc 2 tion Contents 2 Safety precautions 2 Characteristics...

Страница 3: ...and other possible general entrance door panels automatically disconnect If another visitor attempts to call from either a busy interior door panel a number of telephone tones will indicate that the c...

Страница 4: ...een master Nhea terminal Communication LED illuminated green Night mode LED blinking red Doctor mode LED blinking green Function buttons Audio volume control switch Ringtone volume control switch g h...

Страница 5: ...en each long 3 second press before 5 seconds elapse selects a ringtone volume level and so on in carousel mode with the following selections maximum minimum and no volume night mode Note The night mod...

Страница 6: ...plugs supplied with the terminal Fixing the terminal s wall mounting connector to the wall Positioning the terminal 1 2 3 Avoid dusty or smoky environments or locations near sources of heat x 4 30 Con...

Страница 7: ...or of the terminal to the embedding box with the screws supplied Positioning the embedding box and fitting the wall mounting connector Positioning the terminal Avoid dusty or smoky environments or loc...

Страница 8: ...not done the door panel will emit tones to indicate that the system is still in programming mode M S SI Turn off the terminal to be programmed press button for 3 seconds Once switched off press the d...

Страница 9: ...he doctor mode function Doctor mode not activated default setting The doctor mode function enables the lock release to be activated automatically 10 seconds after making a call from the door panel wit...

Страница 10: ...to 3 blinks of the status LED and in the following order 1 2 or 3 repeats When the final selection is reached the following press returns the user to the first selection and the status LED blinks onc...

Страница 11: ...No function Button has no function Accessing Menu 1 or exiting programming mode When exiting advanced programming mode the terminal will be turned off Press button for 1 second to turn the terminal b...

Страница 12: ...ly through the contacts of the SAR 12 24 relay and the maximum consumption of the element to be connected does not exceed 1 8A Vac lock release T 104 F Mains PRI SEC SAR 12 24 IN IN NC NA C Important...

Страница 13: ...SE terminal telephone and monitor This only functions if no call or communication is in progress Anumber of audible tones emitted by the terminal will confirm that the call is being made or that the u...

Страница 14: ...partment front door This feature precludes the need to use the bell by positioning a switch between terminals HZ and of the terminal The ringtones vary depending on where the call is being made from e...

Страница 15: ...mar es search manual 50122328 FA Plus C or FA Plus SEC PRI Mains Place this power supply as close as possible to the first terminal A A _ _ D D A _ D A _ D Access panel M Master D Mesh Vin Ain Aout Vi...

Страница 16: ...olmar se reserva el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior no...

Отзывы: