Programming the NHEA Plus SE terminals:
PROGRAMMING THE TERMINALS
Locate the SW2 DIP switch situated on the top left-hand side of the back of the EL632/PLUS module and
set number 2 to ON. The door panel will reproduce a sound to advise that the system has entered into
programming mode.
In systems with more than one door panel, only perform this procedure on the main door panel of each
building.
8
Press the button of the door panel that will call this terminal.
At this moment, the door panel and terminal handset will emit a number of tones
(the status LED on the terminal will blink red and LED
will illuminate).
Each apartment must only have one master unit; if there are parallel units, either terminals or monitors, they must be
configured as slaves.
Make a call to check that the terminal has been successfully programmed. Programme the other
terminals in the same way.
Once the programming has finished, set the programming switch to OFF. If this is not done, the door panel
will emit tones to indicate that the system is still in programming mode.
M
S
SI
Turn off the terminal to be programmed (press button
for 3 seconds).
Once switched off, press the door release button.
Press and hold the door release button and, without releasing it, switch on the terminal
(press button
for 1 second).
To show that the device is ready for programming, the door panel and terminal
will emit a number of tones (the status LED on the terminal will illuminate red),
enabling the door release button to be released. The terminal is in audio
communication with the door panel.
To programme it as
, press button
once, and the status LED will blink
Slave 1
(green) once. Continue successively to
, pressing button
four
Slave 4
times, and the status LED will blink (green) four times.
NHEA PLUS SE HANDS-FREE AUDIO TERMINAL
To programme the terminal as
, press button
and the LED
Slave + Intercom
will blink (green) once. Then press button
for 1 second (the terminal's status
LED will illuminate red and LED
will turn off).
To programme the terminal as
, press button
for 1 second (the
Master
terminal's LED will illuminate red and LED
will turn off).