26
SPECIAL CODES
Continued from previous page.
Video sources available on a monitor (only setting on master monitor).
Visible
No Visible
Factory setting
Door panel 1
0111
0110
0111
Door panel 2
0121
0120
0120
Camera 1
0141
0140
0140
Camera 2
0181
0180
0180
To
Note: ART4 LITE/G2+ monitor with V.02 and next
define whether the monitor is master or slave (
):
Master
lave
lave
lave
Factory setting
S
1
S
2
S
3
0550
0551
0552
0553
0550 (master)
Automatic opening upon reception of a call on a monitor (only setting on master monitor).
Activated
Deactivated
Factory setting
0441
0440
0440
Activate/deactivate the ('power on indicator' notification icon) and (LEDs of the hidden buttons above raised dots
/
for the visually impaired) on a monitor.
te
te
Activa
Deactiva
Factory setting
0471
0470
0471 (activated)
Do not display the image on monitor when receiving a call from the door panel and the monitor is in "do not disturb"
mode.
Do not display
Display
Factory setting
0481
0480
0480 (
)
enable
Enable/ disable the icon
of the main menu in all monitors.
Enable
Disable
Factory setting
0541
0540
0541 (habilitado)
Activation times of the outputs (Door panel ).
1 (Only setting on master monitor).
Factory setting
Lock release
From 200 (0.5s) to 219 (10s) 20 (3s)
0
0
0
5
Relay
From 300 (0.5s) to 319 (10s) 30 (3s)
0
0
0
5
Setting the remote activation button (Door panel ).
1 (Only setting on master monitor).
Factory setting
Delay
From 400 (0.5s) to 419 (10s) 403 ( s)
0
0
0
2
Output
430 (lock release) or 431 (relay)
430 (
)
0
0
0
lock release
Activation times of the outputs (Door panel ).
2 (Only setting on master monitor).
Factory setting
Lock release
From 200 (0.5s) to 219 (10s) 20 (3s)
1
1
1
5
Relay
From 300 (0.5s) to 319 (10s) 30 (3s)
1
1
1
5
Setting the remote activation button (Door panel ).
2 (Only setting on master monitor).
Factory setting
Delay
From 400 (0.5s) to 419 (10s) 403 ( s)
1
1
1
2
Output
430 (lock release) or 431 (relay)
430 (
)
1
1
1
lock release
Night vision illuminaton leds (Door panel 1), during call or communication process (Only setting on master monitor).
.
Automatic
Always ON
Always OFF
Factory setting
0450
0451
0452
0450 (automatic).
Night vision illuminaton leds (Door panel 2), during call or communication process (Only setting on master
.
monitor).
Automatic
Always ON
Always OFF
Factory setting
1450
1451
1452
1450 (automático)
Activate deactivate the ring tone Door panel
. (Only setting on master monitor)
/
(
1)
:
Activated
Deactivated
Factory setting
1701
1700
1701
Activate deactivate the ring tone Door panel 2 . (Only setting on master monitor)
/
(
)
:
Activated
Deactivated
Factory setting
2
1
2
2
70
700
701
SOUL S5110/ART
VIDEO DOOR ENTRY SYSTEM KIT
7 LITE