24
WIRING DIAGRAMS
Connection of an output button
Connection of an external camera
Connection for an apartment door button
The output button allows remote activation of the lock release connected between the CV- and CV+ terminals (by
default) or the relay output (see pp.
-
). The delay time in carrying out the activation is
seconds, with the
25 26
2
possibility of setting it to between 0.5 and 10 seconds (see pp.
-
).
25 26
It is possible to connect a Golmar AHD4-3601x analogue CCTV camera to each of the door panels, which can be
viewed (see pp.
-
) from the monitor. The camera needs to have a local PSU-121 power supply.
2 26
5
Only connect the apartment door button to the master monitor of the apartment that will be receiving the call (see
note "HZ" page 9). The signal received is then transmitted to the slave monitors in the same apartment.
CV-
GND
BUS
C
CV+
CCTV
AP+
AP-
BUS
NA
HZ
HZ
CV-
GND
BUS
C
CV+
CCTV
AP+
AP-
BUS
NA
SOUL PANEL- /LITE
7
SOUL PANEL- /LITE
7
ART
LITE/G2+
7
Mains
110~240Vac
L
R
PSU-121
POWER SUPPLY
(Code 31690144)
AHD4-3601X ANALOGUE CCTV
CAMERA (Code 31600144)
Important:
Set the camera with a CVBS analogue signal,
as described in the accompanying AHD4-3601x
camera manual.
JOYSTICK
IMPORTANT:
Installation with 2 access door panels and AP button on both door panels, one of the door
panels must connect the AC lock release (instead of DC lock release) with a SAR-12/24 relay and a
transformer TF-104, (see page
.
2 )
3
SOUL S5110/ART
VIDEO DOOR ENTRY SYSTEM KIT
7 LITE