golmar CD-V2PLUS/TP Скачать руководство пользователя страница 15

46

PLUS BUS

V2PLUS BUS

M

C

-

V2PLUS

+

-

SEC

PRI

+

0

110

230

FA-V2PLUS

- - +

Main

Door panel V2Plus

CV1 +12

CV2

BUS

MC-V2PLUS

BUS IN

PA PB

BUS OUT

HZ

BUS

BUS

D

F.Linea

D1L-V2Plus

Riser 1

*

*

Platea V2Plus

Sw2

*

SEC

PRI

+

0

110

230

- - +

Main

FA-V2PLUS

BACKBONE 250

SW1

6

COL 1

COL 2

COL 3

COL 4

PL 1

PL 2

PL 3

M

S

Insert the end of line 120    resistor
in the last V2Plus distributor.

Setting the end of line in the last
monitor.

*

**

To the next 

door panel

Main

Main

M  =Master.

S  =Slave.

S

General door panel

Communication R.: DEACTIVATED

Next Riser

Next distributor

BACKBONE 0

+

BUS

CD-V2PLUS/TP

-

JP1

SEC

PRI

+

0

110

230

FA-V2PLUS

- - +

V

out

-

V

out

+

MALLA

V

in

+

V

in

-

A

in

A

out

D

+

-

CV

+

CV

-

FA-PLUS/C

rev.938072

+

-

230 110 0

- +

SEC

PRI

EL-564

Vp1

-

Malla

-

TP out

Vin

Coax in

Mp1

+

Vp1

Mp1

TP in

Vp1

Mp1

-

2C

D

Ao Ain

_

CT+

MP VP

_

(1) D4L-PLUS

CTin

IN

D1

OUT

JP1

(1) Take off JP1 jumper of all the Plus
     distributors except in the last one.

(2)

(2) 75    fix resistor (

.

internal circuit)

Содержание CD-V2PLUS/TP

Страница 1: ...Protocol converter Instructions manual TCD V2PLUS TP ML rev 0112 C d 50121239 CD V2PLUS TP...

Страница 2: ...anel converter multiplexer monitors telephones and the power supply connection Do always follow the enclosed information When starting the equipment for the first time or after a modification the syst...

Страница 3: ...aximum distance between the power supply and converter 50m with a wire section of 1 5mm Use Golmar RAP 2150 cable in the V2Plus system monitors telephones or call repeaters and 120 monitors telephones...

Страница 4: ...ill be connected to the output of the door panel Another option is for us to place a Plus porter s exchange between the converter and the coded door panel This variation can be applied with or without...

Страница 5: ...nfiguration dip switch Plus Bus connection block TP video V2Plus Bus connection block Label 36 Install the converter in a dry and protected place free from the risk of drip or water projections To avo...

Страница 6: ...igured as Slaves To reset the converter switch to ON and then set to OFF after a Short circuit or programming error Set to ON if there are distributors in the backbone single user or multi user or the...

Страница 7: ...or panel Cancel If there are more converters repeat the previous steps introducing a different backbone code for each of them If during one of these processes the red LED on the converter switches on...

Страница 8: ...ith independent more common wires only use the common wires separate and do not connect the independent ones 1 access door panel up to 3 access door panel with MC V2PLUS multiplexer Up to 32 monitors...

Страница 9: ...NT if the installation includes multiplexers in daisy chain with monitors B W Maximum distance between door panel converter and multiplexer 150m Maximum distance between multiplexer in daisy chain and...

Страница 10: ...15m 15m 15m 15m 15m 15m 50m 100m 100m 150m 35m 70m 100m 200m 35m 70m 100m 26m 46m 67m 67m 16m 33m 67m 100m 16m 33m 67m Use Golmar RAP 2150 cable for new installations Several accesses and risers with...

Страница 11: ...nel STADIO INOX ROCK 230 110 0 SEC PRI Main FA PLUS C ver 938072 D3 BUS IN PA PB BUS OUT HZ F Linea D4L V2Plus BUS IN PA PB BUS OUT HZ BUS D2 D1 BUS D4 Platea V2Plus Sw2 Platea V2Plus Sw2 Configuring...

Страница 12: ...ser MC V2PLUS 1 Insert the end of line 120 resistor in the last distributor Setting the end of line in the last monitor SEC PRI 0 110 230 Main FA V2PLUS BACKBONE 1 IMPORTANT For the configuration and...

Страница 13: ...BUS MC V2PLUS BUS IN PA PB BUS OUT HZ BUS BUS D Platea V2Plus F Linea D1L V2Plus Sw2 Main SEC PRI 0 110 230 Main FA V2PLUS BACBONE 250 SW1 6 M Master S S Slave M 1 S Door panel V2Plus Next distributo...

Страница 14: ...L 2 PL 3 Next Riser M IMPORTANT To configure and to program each equipment see the appropiate instruction book Main Main General door panel Communication R ACTIVATED M Next distributor INSTALLATION DI...

Страница 15: ...tor Setting the end of line in the last monitor To the next door panel Main Main M Master S Slave S General door panel Communication R DEACTIVATED Next Riser Next distributor BACKBONE 0 BUS CD V2PLUS...

Страница 16: ...tly followed see page 38 Check that the voltage in the BUS terminal of the converter is 23 to 25 5 Vdc If that is not the case disconnect the affected terminal wires and check that there are no short...

Отзывы: