24
Continued from previous page.
SPECIAL CODES
Video sources available on a monitor (configure only on the master monitor).
Visible
Not isible
v
Factory setting
Door panel 1
0111
0110
0111
Door panel 2
0121
0120
0120
Door panel 3
0131
0130
0130
Door panel 4
0151
0150
0150
C m ra 1
0141
0140
0140
a e
C m ra 2
0181
0180
0180
a e
C m ra 3
0171
0170
0170
a e
C m ra 4
0191
0190
0190
a e
.
Important: Only available with EL632-G2 + SE video module with 'V03' or later.
General door panels installations, available with EL632-G2+ SE with
’
V04' or later.
To
Note: ART4 LITE/G2+ monitor with V.02 or later
de
fi
ne whether the monitor is master or slave (
):
Master
lave
lave
lave
Factory default
S
1
S
2
S
3
0550
0551
0552
0553
0550 (master)
Automatic door opening upon reception of a call on a monitor (configure only on the master monitor).
Activated
Deactivated
Factory setting
0441
0440
0440
Do not show the image on the monitor when receiving a call from the door panel when the monitor is in 'Do not disturb'
mode.
Show
Do not show
Factory setting
0481
0480
0480 (show image)
Enable/ disable the icon
of the main menu in all monitors (building).
Enable
Disable
Factory setting
0541
0540
0541 (
)
enable
Restore the door panel(s) SoulAccess with the master code to factory default:
“
1234".
All door panels
Door panel 1
Door panel
Door panel
Door panel 4
2
3
8000
8001
8002
8003
8004
LED lights for night viewing (Door panel 1) during a call or communication process. (Configure only on the master
monitor).
Automatic
OFF
Always ON
Always
Factory setting
0450
0451
0452
0450 (automatic).
Activation times of the outputs (Door panel 1). (Configure only on the master monitor).
Factory setting
Relay 1
From
to
0200 (0,5s)
0219 (10s)0205 (3s)
Rel
0300 (0,5s)
0319 (10s)0305 (3s)
ay 2
From
to
Configuration of the remote activation button
(Door panel 1). (Configure only on the master monitor).
Relay1
Factory setting
Delay
From
to
0400 (0,5s)
0419 (10s)0403 (2s)
Configuration of the remote activation button
(Door panel 1). (Configure only on the master monitor).
Relay2
Factory setting
Delay
From 5
to 5
5
0 00 (0,5s)
0 19 (10s)0 03 (2s)
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the master
2
monitor).
Automatic
OFF
Always ON
Always
Factory setting
1450
1451
1452
1450 (automatic).
Activation times of the outputs (Door panel ). (Configure only on the master monitor).
2
Factory setting
Relay 1
From
to
1200 (0,5s)
1219 (10s)1205 (3s)
Rel
1300 (0,5s)
1319 (10s)1305 (3s)
ay 2
From
to
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
Continued overleaf
*
( )
*
( )
ART
/G2+
4
MONITOR
LITE
(1) ART 4 LITE/G2+ V05, ART 4H LITE/G2+ V05, ART 4B LITE/G2+ V05, ART 4TH LITE/G2+ V02 E
ART 4W LITE/G2+ V02
(1)