NOISE 

- Signal-to noise ratio on line input : > 85 dB (0.01 Hz - 10 Mhz). 
- Weighted ASA A : > 90 dB. 
 

OPERATING TEMPERATURE 

- Room temperature : -30 to +40 degrees Celsius ( -22 to +104 degrees Fahrenheit). 
- Internal temperature : +45 to +65 degrees Celsius ( +113 to +149 degrees 
Fahrenheit). 
 

POWER SUPPLY  

- Nominal line voltage : 110, 220 V (selectable). 
- Input voltage range : +/- 10 %. 
- Maximum power consumption : 500 W. 
 

SAFETY FEATURES 

- DC protection threshold : 5 V. 
- HF protection threshold : 3 V RMS at 50 kHz. 
- Input voltage fuse : 3 A slow-blow for 220 V / 5 A slow-blow for 110 V. 
- Short-circuit protection : 2 fuses 5 A fast minimum. 

 
GROUNDING 

- Separated ground and earth signal. 
- Connection optional between earth and ground to cancel all ground loops. 
- Chassis connected to signal grounding. 
 

FRONT PANEL CONTROLS 

- VOLUME control. 
- POWER switch. 
- TAPE MONITOR switch. 
- SELECTOR switch. 
 

REAR PANEL CONNECTORS AND CONTROLS 

- AC line connector 3 lugs. 
- Earthing post (yellow-green). 
- AC voltage switch (110V-220V) 
- Speaker Output binding posts (right and left). 
- Input and tape output  RCA connectors (right and left). 
- Signal grounding post (black). 
 

SIZE AND WEIGHT 

- 48.2 cm (19") W x 34 cm (13.4") D  x 7.2 cm (2.8") H. 
- Weight : 12 kg. 
 

WARRANTY 

- 3 years parts and labor. 

Содержание SRI2

Страница 1: ...1 GOLDMUND SRI2 INTEGRATED AMPLIFIER USER MANUAL...

Страница 2: ...ATED AMPLIFIER USER MANUAL ATTENTION No connection or manipulation must be done before reading these instructions Damage to the amplifier may result if the following instructions are not consciously u...

Страница 3: ...t detrimental but favorable to the sonic quality of the unit which is self protected It is perfectly normal that the heat sink becomes too hot to be touched 3 AC LINE VOLTAGE A voltage indication is p...

Страница 4: ...ound of the input plug and the black speaker terminal are the same polarity The amplifier is non inverting in phase 5 AMPLIFIERS CONTROLS POWER On the back panel of the GOLDMUND SRI2 amplifier you wil...

Страница 5: ...ntrol with soft stop and start is available through the remote control which acts on the potentiometer The additional MEMO key on the remote allows to pre program a standard level to which the potenti...

Страница 6: ...bility to again increase the sonic quality of your speakers by reverting the polarity of the speaker cable amp termination But since the line phase and the speaker polarity interfere to each other you...

Страница 7: ...ifier TECHNICAL DATA POWER Nominal power 2 x 125 W RMS 2 8 Ohms 2 x 80 W RMS 1 16 Ohms Maximum power 2 x 200 W RMS 3 Ohms Maximum voltage 35 V peak Maximum current 25 A peak FREQUENCY RESPONSE These f...

Страница 8: ...low blow for 220 V 5 A slow blow for 110 V Short circuit protection 2 fuses 5 A fast minimum GROUNDING Separated ground and earth signal Connection optional between earth and ground to cancel all grou...

Отзывы: