GOLDMUND METIS 2 - Analog Preamplifier - 6
1
SETTING UP THE METIS 2 (Ctd.)
1.2
CHOICE OF THE PREAMPLIFIER LOCATION
The Goldmund Metis 2 preamplifier generates a significant amount of heat.
It is necessary to allow a proper cooling of the unit. Avoid any location which is not properly
ventilated and avoid placing the Metis 2 on top of any equipment that is generating high
temperature.
1.3 LINE VOLTAGE ADJUSTMENT
A voltage selector is provided on the back plate of the preamplifier. Adjust it with a
screwdriver if the line voltage provided is not appropriate.
ATTENTION: On the 220V position, the Goldmund Metis 2 preamplifier will function
properly for main line voltage in between 200V and 250V. On the 110V position, the main
line must deliver between 105 and 125V. If your main line is usually out of these tolerances,
please consult your Goldmund dealer.
Please check the value of the main line fuse. This fuse is located on the power cord
receptacle. The lid can be removed with a small screwdriver when the cord is removed.
Use a 500mA slow-blow fuse for 220V and 110V.