background image

 

GOLDMUND METIS 2 - Analog Preamplifier - 3 

 
 

Table of Contents 

 
 
 
 

 

SETTING UP THE METIS 2 

FIRST INSTALLATION & CONNECTIONS 

SOUND QUALITY OPTIMIZATION 

5 CLEANING 

6     TECHNICAL SPECIFICATIONS 

10 

 
 
 

Содержание METIS 2

Страница 1: ...USER MANUAL GOLDMUND METIS 2 Analog Preamplifier...

Страница 2: ...978 and has ever since been dedicated to the accurate reproduction of sound and image At Goldmund we strive to lead in the creation development and manufacture of the industry s most advanced technolo...

Страница 3: ...GOLDMUND METIS 2 Analog Preamplifier 3 Table of Contents 1 SETTING UP THE METIS 2 5 2 FIRST INSTALLATION CONNECTIONS 7 4 SOUND QUALITY OPTIMIZATION 9 5 CLEANING 9 6 TECHNICAL SPECIFICATIONS 10...

Страница 4: ...e ultra high bandwidth which are becoming necessary for an accurate transcription of today s best analog messages in complete systems with video computer and audio associated components Only a careful...

Страница 5: ...tal signals The connections between the analog sources and the preamplifier are critical Ultra low reflection cables are absolutely mandatory Goldmund recommends using the Goldmund Interconnect cables...

Страница 6: ...rovided on the back plate of the preamplifier Adjust it with a screwdriver if the line voltage provided is not appropriate ATTENTION On the 220V position the Goldmund Metis 2 preamplifier will functio...

Страница 7: ...tion you may have to use the earth connection of the AC plug and lift the earth connection of the other equipment 2 2 SOURCES CONNECTION Connect the interconnects between the preamplifier analog outpu...

Страница 8: ...liability Goldmund recommends that the unit is left powered ON MUTING Muting is controlled from the remote control It can be used to temporarily turn the volume down without touching the volume contro...

Страница 9: ...d for a few days the optimum sound quality is only reached after a few hours This is why Goldmund recommends leaving the METIS 2 powered on 5 CLEANING The Goldmund Metis 2 preamplifier usually require...

Страница 10: ...to maximum output level 0 1 dB 10 20 kHz 1 5 dB 10 100 kHz 3 dB 10 200 kHz GROUP DELAY Propagation delay 1 ms stable with frequency from DC to 100 kHz DISTORTION With 1 V RMS output level 80 KHz measu...

Страница 11: ...mperature 45 to 65 degrees Celsius 113 to 149 degrees Fahrenheit POWER SUPPLY 1 Power Transformer Nominal line voltage 110 V or 230 V Input voltage range 10 Maximum power consumption 10 W GROUNDING Se...

Страница 12: ...W x 285 mm 11 22 D x 60 mm 2 36 H Power Supply 70 mm 2 75 W x 70 mm 2 75 D x 32 mm 1 25 H Preamplifier Box 360 mm 14 17 W x 360 mm 14 17 D x 112 mm 4 4 H Weight Total Weight 3 5 Kg 7 71 lb Total Weigh...

Отзывы: