OPERATION

Operation - all models

The wireless remote display/keypad communicates with the base receiver on the
Aqua Logic control unit using RF (radio frequency) technology.  All of the display
information is transmitted from the Aqua Logic control unit to the wireless remote
display/keypad and all the button press information is transmitted by the wireless
remote display/keypad unit back to the Aqua Logic control unit.

If the display information is not being updated on a regular basis or if the Aqua Logic
is not responding to buttons being pressed, then refer to the Troubleshooting sec-
tion for assistance in resolving these problems.

When power is turned on to Wall Mount models, or when the Table Top models
"wake up", all the LED indicators will flash briefly, the display backlight will illuminate,
and the following display will appear for a short period of time:

The "r2.00" is the software revision level.  The actual revision level for your wireless
remote display/keypad may be different.  Refer to the Aqua Logic Operation Manual
for complete operating instructions.

Operation - AQL-Tx-RF-PS-x  Table Top models

Because the AQL-Tx-RF-PS-x is battery operated, it displays various information
about its condition and the status of its batteries.  Refer to the section below for an
explanation of these displays:

Shutting down to

save battery power

After one minute of no button presses, the AQL-Tx-RF-PS-x will briefly show this
display and go into "sleep" mode.  This mode conserves the battery power while the
remote is not in use.  While asleep, all lights and the display will be off.  To "wake" the
unit up, push any button on the keypad.

Refreshing display

When the AQL-Tx-RF-PS-x "wakes" up, it will show this display while it collects
status information from the Aqua Logic control unit.

Please plug in to

charge battery

When the batteries are low, the Table Top unit will alternate between this display and
the normal status display.  Under typical conditions, there are at least 50 more one-
minute uses available when this display is first shown.  The batteries will slowly lose
charge if the unit is not plugged into the wall, even if it is not used.

Goldline Aqua Logic

RF Display r2.00

Содержание AQL-Tx-RF-PS-16

Страница 1: ...mation and Chlorination Installation Operation Manual for models AQL WW RF PS 4 AQL WW RF PS 8 AQL WW RF PS 16 AQL Tx RF PS 4 AQL Tx RF PS 8 AQL Tx RF PS 16 LD C G LINE ON TROLS INC Wall Mount models...

Страница 2: ...st be mounted indoors or in a weather protected area rain should never hit the wireless remote display keypad The wireless remote display keypad is designed to mount onto a standard electrical utility...

Страница 3: ...e intended to be used in the normal living space with these considerations Protected from the weather The wireless remote display keypad should be used indoors or in a weather protected area rain shou...

Страница 4: ...ower When the charger is not plugged into the AQL Tx RF x the unit uses bat tery power and will take steps to extend battery life After one minute of no button presses by the user the unit will show a...

Страница 5: ...pad for 4 seconds At this point the LCD on the wireless remote display keypad will indicate Teach Wireless Success ful and the local display keypad on the Aqua Logic control unit will also confirm Tea...

Страница 6: ...erent Refer to theAqua Logic Operation Manual for complete operating instructions Operation AQL Tx RF PS x Table Top models Because the AQL Tx RF PS x is battery operated it displays various informati...

Страница 7: ...ng the same frequency To see if this is the case go to the Settings Menu Wireless Channel and select another channel Note that after you change the channel you will have to re teach every wireless rem...

Страница 8: ...the desired operation press the Menu button to lock in your setting Note that this selection applies to this display keypad only Repeat the process for each dis play keypad in the system 7 The last k...

Страница 9: ...loser to the Aqua Logic main control unit base receiver 11 Display Error 1 call 888 921 7665 Display Error 2 call 888 921 7665 Display Error 3 call 888 921 7665 An internal problem has occurred in the...

Страница 10: ...datecode on the Aqua Rite Aqua Trol or Aqua Logic electronics unit will be the sole determinant of the date of the initial system installation If a product is defective in workmanship or materials and...

Страница 11: ...fore the certification registration number only signifies that the Industry Canada technical specifications were met Interference This equipment has been tested and found to comply with the limits for...

Отзывы: