8.  Troubleshooting Tips 

 

 

8.1.   What to do if the device doesn’t work? 

1.  Ensure the device is plugged into a working wall socket. 
2.  Ensure the plug is wired correctly and terminal well-connected. 
3.  If  you  still  have  issues  with  the  device,  please  contact  your  local  dealer  or  our 

customer service for assistance. 

 
 

 

8.2.   How often should the UV tube be replaced? 

1.  The UV tube is the core of the product, it should be replaced after 9000 hours of use 

to maintain the germicidal efficacy. 

2.  The UV tube is defected if it flashes, please contact your local dealer or our customer 

service  to  order  a  new  UV  tube.  For  replacing  the  UV  tube,  please  refer  to  the 
instructions in this user manual. 

3.  After use for a period of time, it is normal to find some black spots on both sides of 

the UV tube. 

 

 
 

8.3.   The Audio alarm signal and LED indicator signal for this product: 

 

Status 

Audio Alarm 

Power Indicator 

Standby 

Green indicator on 

Delayed 
Start 

Beeping for 3 minutes regularly 
(frequency increase in the 
countdown 10 seconds) 

Red indicator flashing for 3 minutes 
regularly (frequency increase in the 
countdown 10 seconds) 

Lamp 
Strike 

UV Lamp on after 15 seconds 
when the beeping stops 

Red indicator on after beeping stops 

Emitting 
(working) 

Single Beeping every 10 seconds 

Red indicator on 

Motion 
Detected 

Dual beeping every 10 seconds 

Red & Green indicators flashing 

End of 
Cycle 

Triple beeping every 10 seconds 
(in 30 seconds) 

Green indicator on 

Fall 
protection 

Quadruple ping every 10 seconds  Green indicator flashing 

 

Содержание UVM216

Страница 1: ...UVM216 USER MANUAL KEEP THIS MANUAL FOR FUTURE NEEDS...

Страница 2: ...isfied with our excellent products and service For your own safety please read this user manual carefully before installing and operating the device Contents 1 Safety Instructions 2 2 Features 5 3 Pro...

Страница 3: ...Do not continue to use the products when the lamp is damaged 9 Do not use the product under the interference of strong electric fields and magnetic fields 10 Insufficient disinfection time or insuffic...

Страница 4: ...If users fail to use the series of products in accordance with the guidelines or regulations laid out above and in this manual GOLDENSEA will not be liable for any losses damages or consequences caus...

Страница 5: ...e according to your local regulations Do not touch any metal parts exposed to air which is falling off or broken when the fixture is powered on to avoid risk of electric shock The operator must wear a...

Страница 6: ...30W Light Source Lamp TUV 36W SLV 6 T8 PHILIPS or HNS L 36W G13 G36T8 OF PURITEC UV C Germicidal Low Pressure Lamp OSRAM Extremely long Life up to 9 000 H Features Delayed start 3 min delayed start Mo...

Страница 7: ...www goldenseauv com 6 Accessories List UV Tube Included Remote Control battery type CR2025 Included UV Glasses protective eyewear Included Warning Sign Included UV Irradiance Meter Optional...

Страница 8: ...1 Grid Opening Tabs 2 Handle 3 Protective Grid 4 UV Tube 5 Power Switch 6 Power Cable 7 Universal Wheel 8 Brake Lever 9 Indicator Lights 10 30 mins touch key 11 60 mins touch key 12 120 mins touch ke...

Страница 9: ...www goldenseauv com 8 4 Dimensional Drawings...

Страница 10: ...e the recommended disinfection times and areas are 30mins 60m 60mins 120m 120mins 240m 6 1 Preparation 1 Make sure the device is on an even surface and the wheel brakes are engaged 2 Make sure NO livi...

Страница 11: ...ator will stay on during the entire disinfection process 6 Once the disinfection process has ended the red indicator on the button will turn off and the power indicator will switch to green An audible...

Страница 12: ...the disinfection process is stopped by the motion sensor a dual audible alarm will start beeping and the red and green power indicators will flash until the operator restarts the device Note if the de...

Страница 13: ...and handles for fast and easy relocation 1 Before moving the device make sure the power cable is disconnected from power socket and the wheel brake is released To release the brake push the brake leve...

Страница 14: ...as shown and take it out from its holder Note please follow your local toxic and hazardous waste regulations for lamp disposal 5 Insert the new UV tube into the holder and turn the UV tube 90 anti clo...

Страница 15: ...to the instructions in this user manual 3 After use for a period of time it is normal to find some black spots on both sides of the UV tube 8 3 The Audio alarm signal and LED indicator signal for thi...

Страница 16: ...ide towards the device it can discolor or damaged 5 Should you need any spare parts please order genuine parts from your local dealer 10 Service For all service needs please contact your local authori...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: