7.  Take the remote control with you when exiting the disinfection area or store it in the 

remote control bag. 

8.  Close the door of the disinfection area. 
9.  If there is a significant gap on the door, please make sure the gap is closed before 

operating. 

 
 

6.2.   Control Panel Operation 

1.  Connect  the  power  cable  of  the  device  to  the  power 

socket,  press  the  power  switch    <  I/O  >  to  <I>,  the 
green power indicator light turns on. 

2.  Press the <30 mins>, <60 mins > or <120 mins > touch 

key  to  select  your  desired  disinfection  time,  the 
corresponding indicator light under the touch key turns 
on. 

3.  Press  the  start  button  <

>,  then  audible  alarm  will 

start  beeping  and  red  power  indicator  will  flash 
regularly for 3 minutes. 

4.  You  must  exit  the  disinfection  area  during  this  3 

minutes. 

5.  Once the countdown has ended, the UV tubes will be activated and light up, and the 

red power indicator will stay on during the entire disinfection process. 

6.  Once the disinfection process has ended, the red indicator on the button will turn off 

and the power indicator will switch to green. An audible alarm will be also beeping to 
notify the user. Now it is safe to enter the disinfection area. 

7.  Upon  entering  the  disinfection  area,  please  open  the  windows  to  ventilate  the 

disinfected area (you may find an unusual smell as a result of disinfection process, 
which is normal and harmless). 

 
 
 

6.3.   Remote Control Operation 

1.  Connect  the  power  cable  of  the  device  to  the  power  socket,  press 

power switch <I/O> to <I>, the green power indicator light turns on. 

2.  Exit the disinfection area and close the door. 
3.  Take  the  remote  control  and  press  <30'>,  <60'>  or  <120'>  button  to 

select your desired disinfection time, the corresponding indicator under 
the touch key on the device turns on. 

4.  Press the start button <

>, then audible alarm will start beeping and 

red power indicator will flash regularly for 3 minutes. 

5.  If you are still inside the disinfection area, you must exit during this 3 

minutes. 

Содержание UVM216

Страница 1: ...UVM216 USER MANUAL KEEP THIS MANUAL FOR FUTURE NEEDS...

Страница 2: ...isfied with our excellent products and service For your own safety please read this user manual carefully before installing and operating the device Contents 1 Safety Instructions 2 2 Features 5 3 Pro...

Страница 3: ...Do not continue to use the products when the lamp is damaged 9 Do not use the product under the interference of strong electric fields and magnetic fields 10 Insufficient disinfection time or insuffic...

Страница 4: ...If users fail to use the series of products in accordance with the guidelines or regulations laid out above and in this manual GOLDENSEA will not be liable for any losses damages or consequences caus...

Страница 5: ...e according to your local regulations Do not touch any metal parts exposed to air which is falling off or broken when the fixture is powered on to avoid risk of electric shock The operator must wear a...

Страница 6: ...30W Light Source Lamp TUV 36W SLV 6 T8 PHILIPS or HNS L 36W G13 G36T8 OF PURITEC UV C Germicidal Low Pressure Lamp OSRAM Extremely long Life up to 9 000 H Features Delayed start 3 min delayed start Mo...

Страница 7: ...www goldenseauv com 6 Accessories List UV Tube Included Remote Control battery type CR2025 Included UV Glasses protective eyewear Included Warning Sign Included UV Irradiance Meter Optional...

Страница 8: ...1 Grid Opening Tabs 2 Handle 3 Protective Grid 4 UV Tube 5 Power Switch 6 Power Cable 7 Universal Wheel 8 Brake Lever 9 Indicator Lights 10 30 mins touch key 11 60 mins touch key 12 120 mins touch ke...

Страница 9: ...www goldenseauv com 8 4 Dimensional Drawings...

Страница 10: ...e the recommended disinfection times and areas are 30mins 60m 60mins 120m 120mins 240m 6 1 Preparation 1 Make sure the device is on an even surface and the wheel brakes are engaged 2 Make sure NO livi...

Страница 11: ...ator will stay on during the entire disinfection process 6 Once the disinfection process has ended the red indicator on the button will turn off and the power indicator will switch to green An audible...

Страница 12: ...the disinfection process is stopped by the motion sensor a dual audible alarm will start beeping and the red and green power indicators will flash until the operator restarts the device Note if the de...

Страница 13: ...and handles for fast and easy relocation 1 Before moving the device make sure the power cable is disconnected from power socket and the wheel brake is released To release the brake push the brake leve...

Страница 14: ...as shown and take it out from its holder Note please follow your local toxic and hazardous waste regulations for lamp disposal 5 Insert the new UV tube into the holder and turn the UV tube 90 anti clo...

Страница 15: ...to the instructions in this user manual 3 After use for a period of time it is normal to find some black spots on both sides of the UV tube 8 3 The Audio alarm signal and LED indicator signal for thi...

Страница 16: ...ide towards the device it can discolor or damaged 5 Should you need any spare parts please order genuine parts from your local dealer 10 Service For all service needs please contact your local authori...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: