![Golden Technologies GP162 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/golden-technologies/gp162/gp162_owners-manual_2240730027.webp)
27
VII. OPERATION
THERMAL ROLLBACK
Your
LiteRider Envy
is equipped with a safety system. A microprocessor monitors the
operating temperatures of the controller. In the event of excessive heat occurring in the
controller, the controller will decrease the speed of your chair. This is done to reduce the
load on the electrical system and allow the components to dissipate heat. The
controller will automatically set the chair’s speed back to full normal when the operating
temperature returns to normal levels.
THE MAIN CIRCUIT BREAKER
The main circuit breaker is another safety feature incorporated into your
LiteRider Envy
.
This device monitors the amount of current being drawn from the batteries when the
chair is in use. When the motors are heavily strained and too high a current draw is
being placed on the batteries, the main circuit breaker will trip and bring your chair to a
stop. The main circuit breaker is located under the battery box handle.
RESET BUTTON
If the main circuit breaker trips, please wait for approximately 1 minute and then push
the reset button to reset the main circuit breaker. See figure 16.
Usually, the thermal rollback feature is more sensitive than the main
circuit breaker. We recommend that you turn off the power to the chair and wait for five
minutes when the chair suddenly loses speed or power. Doing so will allow the
overheated electrical components to cool to their normal operating temperatures.
Figure 16
Содержание GP162
Страница 35: ...35 ...
Страница 36: ...36 Fold Here First Golden Technologies 401 Bridge Street Old Forge PA 18518 Fold Here Second Place Stamp Here ...
Страница 37: ...37 ...