PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007
20
ALA26
Lowcell Alert ON
If it is selected, the pager emits a, low battery cell alert when the battery reaches
a low cell state.
4
Polarity
It select the RF signal polarity is normal or invert.
4
Sequential Lockout
The value is a sequential lockout timer begins when a message arrives and is
flagged as being sequentially locked out. If duplicate messages arrive, one of the
messages is disregarded and not flagged as a duplicate. Valid selections are
disabled, 30 seconds, 60 seconds, 120 seconds, 175 seconds and 240 seconds.
4
Reminder Duration
With this option selected, the time period begins with a newly arrived message
and is reset every time a new message is received. Once the time period expires,
the pager does not emit any more reminder alerts until a new message arrives.
Valid time period selections are: Disable, 2 minutes, 10 minutes and 60 minutes.
4
Out-of Service Control
With an out-of-service time specified by the code plug, the pager is considered
“out of service” when it does not detect a POCSAG synchronization word for that
time period. The out-of-service icon displays at this time. Valid selections are:
disabled, 1 min, 2 min, 5 min and 10 min.
4
Read Time Out
The current pager display changes after the selected time frame has expired.
Valid selections are: 8 sec, 12 sec, 20 sec, 30 sec.
4
Password (4 Dec)
It is used for the user’s manual programming.
4
Screen Contrast
It selects the LCD display contract level.
Counter Out Enable
If it is selected, the message will indicate the counter number at first.