WG600S Industrial Basic Variable-Speed Peristaltic Pump
not work
keypad and the main board.
2. Check if the key is broken.
6
Hardware
External
control does
not work
1. Check the wiring of the connector.
2. Check if the external control power
voltage is provided.
3. Check the connections of the external
control board.
4. Check the
DIRECTION
switch if it is
on the middle position.
7
Hardware
RS485 com
does not
work
1. Check the wiring of the connector.
2. Check if the external control power
voltage is provided.
3. Check the connections of the
communication board.
4. Check the
DIRECTION
switch if it is
on the middle position.
8
Hardware
Noisy when
running
Check the screws and lever on the pump
head to make sure they are secure.
9
Software
External
control does
not work
Check if pump is on External Control
Mode.
10
Software
RS485 does
not work right
1. Check if pump is on Communication
Mode.
2. Reset the address of the pump.
3. Check whether on the bus there are
two pumps using the same address
If the problem can not be solved, please contact the manufacturer or
distributor.
17