Caramatic
ProTwo
part no. 02 592 99
1
5
Area of Application
•
Caravan
•
Motor caravan
Observe EN 1949 and, in Germany, DVGW worksheet G 607.
The automatic changeover valve is not suitable for mobile homes and sea water
applications.
Place of operation
•
operation in weatherproof and sun-protected outdoor areas
•
in the gas cylinder box with ventilation
Do not install in areas where the temperature exceeds 50°C or falls below –20°C.
Installation position
Right
Wrong
The automatic changeover valve must be installed so that the hose connections are at the
highest position; at least above the cylinder valve.
To prevent re-liquefied gas getting into the regulator, this pressure regulator may not be
installed lower than the tank or cylinder valve. Pipes and hoses that are connected to the inlet
connector of the pressure regulator must have a constant downward incline to the tank or
cylinder.