Automatic Changeover Valve AUV PS 16 bar
part no. 02 253 48 d
5 / 12
CONNECTIONS
Inlet,
optional
Trading name and dimensions
acc. to standard
Installation notes
Italian connection
•
with rubber gasket and cap nut
•
G.1
= Thread W 20 x 1/14 ÜM
Spanner size 25
Hexagonal
Large cylinder connection GF
•
with aluminium gasket
•
G.4
= Thread W 21.8 x 1/14 lh
Spanner size 30
Hexagonal
Small cylinder KLF
•
with 5-wing cap nut
•
G.12
= Thread W 21.8 x 1/14 ÜM
Tighten hand-tight.
Male thread connections
•
G.13
= thread M 20 x 1.5
Tightening torque:
Coupling nut =
4 to 5 Nm
Outlet,
optional
Trading name and dimensions
acc. to standard
Installation notes
Thread connection
•
H.1
= Thread M 20 x 1.5
Tightening torque:
Coupling nut =
10 Nm
M thread connection for GF
•
Y.6
= Thread W 21.8 x 1/14 lh
For connection to
GF connection G.4
or Kombi G.5
All
G. and H.
connections
according to EN 16129. Other connections may also be used.
ASSEMBLY
Before assembly, check that the product is complete and has not suffered any damage during
transport.
ASSEMBLY must be carried out by a specialised company.
See USER QUALIFICATION!
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
Risk of injuries due to blown-out metal chips!
Metal chips may cause eye injuries.
Wear safety goggles!