Page | 4
GENERAL PRINCIPLES OF CONNECTION FOR REAR AND TOP FLUE OUTLETS (WHERE POSSIBLE)
Instructions for the installer:
Always respect the rules in force of the country where the unit is being installed.
Make sure the chimney conduit is of good quality. The quality of the chimney conduit will determine the end
result.
It is essential to check that the room in which the appliance is installed is sufficiently ventilated to provide
adequate air supply.
The majority of problems experienced during the operation of the unit are related to an adjustment in the
specified chimney conduit. We cannot emphasize this point enough.
A comparison cannot be made with previous unit’s results where the air supply is different.
An efficient chimney must be built with materials, which have poor heating conductive capacity.
The minimum cross section of the chimney for a fireplace working with the doors shut is 2.5dm2 (39sq.in), which
corresponds to 180mm (7.09in) diameter (according to French regulations). A flue pipe conduit of 150mm can
be used and it is recommended that the height of the flue is not less than 5 metres.
In no case can this section be reduced, otherwise its flow capacity shall be reduced, and it would cause smoke to
spread into the room when the fireplace’s door is open.
The chimney must be perfectly airtight.
The chimney must only vent one fireplace.
It must suitably emerge into free air at least 0.40m (15 in.) above the rooftop or any other obstacle situated
within a distance of 8 meters (27 feet) from the chimney.
The height of the chimney deviation must be very open angled.