In cases the repair or replacement reveals to be too expensive compared to the price of the 
appliance, the decision to replace or to repair the appliance is to be taken by Godin after sales 
service only. 

 

Parts not covered by warranty

1.  GLASS 

– ceramic glass can withstand temperatures of up to 750°C. The glass can only 

break because of a mechanical shock while using or handling the appliance. (it is important 
to always ensure that any glass retaining clips or brackets are not over tightened).  

2.  Glass seals and ceramic rope seals are considered wear and tear items. 

The following will invalidate any warranty

1.  Damage caused by burning fuels other than those for which the unit is intended. 
2.  Any defect or deterioration caused by a fall, shock, negligence or lack of supervision and 

maintenance. 

3.  Deterioration of parts caused by abnormal conditions (back draft, dampness, storm effects, 

pressure and depression of non conform, temperature shock etc). 

4.  Abnormal usage of the unit (using a unit with the door open, running it on maximum for 

extended periods)or abnormal usage of the appliance in conditions that are different from 
the conditions in our manual for which it has been designed, for example non observation 
of our technical manuals (wrong electric connection, running an empty boiler etc)  

5. 

Any defect, deterioration or accident caused by fall, shock, negligence, lack of the buyer’s 
supervision or maintenance. 

6.  Any modifications or transformations made to the unit and non-compliance with installation 

norms. 

 
Godin SA will not be responsible for any installation, assembly, dismantling costs and consequential 
removal of the appliance. 
 
Consequently Godin SA, cannot be held responsible for any materials loss or human accidents, being 
a result of incorrect installation non 

– observing the legal provisions and regulations (for example, 

lack of ground connection, incorrect draft of the chimney etc...) 
 
In order to constantly improve our products, we reserve the right to modify our appliances without 
prior notice. All the dimensions and specifications give are subject to variation according to technical 
requirements. 
In case of a problem occurred during your guarantee period, please contact your retailer providing 
him with a copy of your bill and guarantee containing the appliances product codes, the retailers 
stamp, the date of the appliance installation.

 

Содержание 364120

Страница 1: ...Page 1 Chevannes Ref 364120 ...

Страница 2: ... tested according to the European norms NF EN 13240 Technical characteristics Linedrawing Unit dimensions mm 883 x 617 x 384 height x width x depth Fire box dimensions mm 350 x 570 x 250 height x width x depth Flue Diameter 180 mm Flue outlet Top or rear Recommended fuel Wood Log size loading from the front 50cm Panoramic glass resistant to 750 deg C Yes Cast iron firebox Yes Air Regulation Yes ma...

Страница 3: ...arantee sufficient draught flow capacity this is of the utmost importance It is of course preferable that this appliance be installed by an installation professional which knows of all relevant codes of practice and safety regulations and can guarantee flawless installation WARNING most values indicated in this instruction manual safety distances flue pipe diameter draught etc are directly drawn f...

Страница 4: ... air supply is different An efficient chimney must be built with materials which have poor heating conductive capacity The minimum cross section of the chimney for a fireplace working with the doors shut is 2 5dm2 39sq in which corresponds to 180mm 7 09in diameter according to French regulations A flue pipe conduit of 150mm can be used and it is recommended that the height of the flue is not less ...

Страница 5: ... chimney cleaned Important The flue pipes gets hot make sure that they are away from any combustible materials If the floor is made of combustible material it will be necessary to protect the floor with an insulted plate made of non flammable material The protection must extend at least 40cm beyond the unit Use flue pipes of the stipulated diameter and preferably enamel as they are less corrosive ...

Страница 6: ...ctions in the chimney before lighting Loading important advice When loading the unit make sure that the fire is burning on low Do not open the door of the unit if running the heater on high or if large flames are visible If opening the door when the flames are visibly high there is a risk they could leap outside the fire cavity Always open the door gently allowing the draught to stabilize and to a...

Страница 7: ...hazard it is important to monitor the use of the unit It is possible to maintain the chimney with GODIN net ref 0008 chimney cleaner however it is still important to have the annual chimney sweep Check the appliance and make sure the door seals are in a good state Replace if necessary Clean the unit inside including the fume passages Clean the glass with GODIN net ref 0009 Maintenance Have your un...

Страница 8: ...nstantly improve the quality of our products the GODIN CO reserves all rights to modify their appliances without notice Fitting the deflector plate When fitting the deflector plate the following steps need to be followed 1 Insert the deflector vertically through the front of the unit and lift it into position 2 Place the deflector as shown below a The rear of the plate seats on the cast iron ledge...

Страница 9: ...Page 9 Parts blow up and list ...

Страница 10: ...ks 3 Articulation mechanisms Door hinges and handles etc 4 Fans thermostats for overheating of appliances equipped with blast engine 5 Temperature control elements oven thermostats and for fan heated gas electric cookers 6 Burners catalysers burner rings for fuel appliances 7 Boilers for central heating and cooking systems for wood coal Our appliances have been specially designed to facilitate rep...

Страница 11: ... the appliance in conditions that are different from the conditions in our manual for which it has been designed for example non observation of our technical manuals wrong electric connection running an empty boiler etc 5 Any defect deterioration or accident caused by fall shock negligence lack of the buyer s supervision or maintenance 6 Any modifications or transformations made to the unit and no...