37
6.2.1 Height adjustment
1) Note the distance in mm the applicator head start position is too low or too high
2) Bring the applicator head in its lowest possible position by selecting “3” on the keypad
3) Remove screws (A) and remove the applicator head (B)
4) Loosen locknut (C) against nut (D)
5) Hold piston rod (E) and rotate nut (D) to move the applicator head bracket in the desired
direction 6/ tighten locknut (C) with the applicator bracket in the new position
7) Remount the applicator head but only loosely tighten the screws (A). You must still be able to
move the applicator head. Move the head as far as possible in the direction of arrow “F” (away
from the printer).
8) Bring the piston back in its upper position by selecting “3” on the keypad again
9) Check whether the vertical position (start position) is correct now. If not please repeat the
procedure until the vertical position is correct.
CONTINUE NOW WITH § 6.2.2
6.2.2 Horizontal adjustment after vertical adjustment
After adjusting the vertical start position of the applicator head it is always necessary to also set
the horizontal position again. You do so as follows:
1) Slide the applicator head towards the printer until it is 0,5mm – 1,0mm from the peeler edge
2) Make sure the peeler edge and applicator head are placed perfectly parallel to each other
3) Select key “3” on the keypad to bring the applicator head in its lowest position
4) Tighten the screws (A)
5) Select key “3” again to bring the applicator head back in start position
6) Verify whether the horizontal position is correct. If not repeat the procedure until all corrected.
7) Leave the MANUAL menu by activating the START button and run a test cycle
6.2.3
Horizontal adjustment without vertical adjustment
In case the original starting height of the applicator head is correct but you need to change the
horizontal position of the head, you proceed as follows:
1) Measure where and to what extend the distance between applicator head and peeler edge
must be corrected
2) Bring the applicator head in its lowest possible position by selecting “3” on the keypad
3) Loosen the screws (A on picture 2 on the previous page) and move the applicator head (B,
same picture) into the desired horizontal position
4) Tighten the screws (A)
5) Bring the applicator back in start position with key “3” on the key pad
6) Verify whether the horizontal position is correct now. If not repeat the procedure until all correct.
7) Leave the MANUAL menu by activating the START button and run a test cycle
Содержание AG3000
Страница 28: ...28 Pic 7 select the icon shown below to return to main menu Pic 8 Back on main menu ...
Страница 36: ...36 Pictures 2 Picture 3 ...
Страница 43: ...43 10 Wire diagrams 10 1 Power and signals schematic 10 2 Control unit picture ...
Страница 44: ...44 10 3 Power circuits 10 4 Connector rack detailed view ...
Страница 45: ...41 10 5 Connector rack diagram ...
Страница 46: ...42 10 6 Electro pneumatic diagram 10 6 PLC Printer applicator port diagram ...