GP-PWM-10-FM
19
© 2018 Go Power!
<= 11.0 VDC
100%
Shows only after full Boost
or Equalization Cycle
90%
>= 12.8 VDC
𝑆𝑆𝑆𝑆𝑆𝑆
=
𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏
𝑣𝑣𝑣𝑣𝑣𝑣𝑏𝑏𝑏𝑏𝑣𝑣𝑏𝑏 −
11.0
𝑉𝑉
1.8
𝑉𝑉
∗
90%
<12.8 VDC and > 11.0
VDC
0%
<= 11.0 VDC
9.0 USB Charging
The GP-PWM-10-FM offers a standard USB connector for delivering 5.0
VDC to small mobile appliances such as cell phones, tablets or small
music players. This charging port is capable of supplying up to 1500 mA
of current.
Remove the rubber cover of the USB terminal to access the terminal.
The USB charging port is always active when the
USB symbol
appears
on the display.
The controller disables the USB charger automatically if the battery
voltage drops below 11.0 VDC. If there is enough current from the PV
panel/array available to charge the Battery to above 12.8 VDC, the USB
terminal will be enabled again.
WARNING:
Do not connect the charging device anywhere else! USB-
Negative contact is connected to battery negative.
10.0 Frequently Asked Questions
(FAQs)
Before a problem is suspected with the system, read this section. There
are numerous events that may appear as problems but are in fact
perfectly normal. Please visit
gpelectric.com
for the most up-to-date
FAQs.