2-3-3.
GP400 Specification
Electrical
Specification
Model No.
Item
GP400-112
GP400-124
GP400-148
Input
Voltage
12VDC
24VDC
48VDC
Voltage Range
10.5~16.0VDC
21.0~32.0VDC
42.0~64.0VDC
No Load Current
<1A @12VDC
<0.5A @24VDC
<0.25A @48VDC
Power Saving Mode
<0.2A @12VDC
<0.1A @24VDC
<0.05A @48VDC
Efficiency (Typ.)
88%
89%
90%
On Mode @ Save Mode
<1A @12VDC
<0.5A @24VDC
<0.25A @48VDC
On Mode @ No Load Mode
<0.2A @12VDC
<0.1A @24VDC
<0.05A @48VDC
Output
Continuous Output Power
400 W (± 3%)
Max. Output Power (1Min.)
> 400 W~460 W (100%~115%)
Surge Power (1Sec.)
< 800 W
Frequency
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
Output Voltage
100 / 110 / 115 / 120 VAC ± 5% (Dip Switch Selectable)
Short-Circuit Protection
1 Sec Shutdown
Output Waveform
Pure Sine Wave (THD < 5%@ Normal Load)
Protection
Input Over-Voltage
Protection
16.0 ± 0.3VDC
32.0 ± 0.5VDC
64.0 ± 1.0VDC
Input Under-Voltage
Protection
10.5 ± 0.3VDC
21.0 ± 0.5VDC
42.0 ± 1.0VDC
BAT. Low Shutdown
10.5 ± 0.3VDC
21.0 ± 0.5VDC
42.0 ± 1.0VDC
BAT. Low Alarm
10.5 ± 0.3VDC
21.0 ± 0.5VDC
42.0 ± 1.0VDC
BAT. Low Restart
14.5V± 0.3V
28.0 ± 0.5VDC
56.0 ± 0.5VDC
BAT. High Shutdown
16.0 ± 0.3VDC
32.0 ± 0.3VDC
64.0 ± 0.3VDC
BAT. High Restart
12.5V± 0.3V
25.0V± 0.3V
50.0± 0.3V
Environment
Working Temp.
-20
℃
~40
℃
Storage Temp.
-30
℃
~70
℃
Working Humidity
10~95% RH, non-condensing
Safety &
EMC
Safety Standards
Certified UL 458
(UL only for GFCI receptacles)
----
EMC standards
Certified FCC class B
E-mark
----
Others
Dimension(WxHxD)
150 mm X 68mm X187 mm
Weight
1.256kg
Remote Control
CR-8 (optional)
Cooling
Temperature & Load Controlled cooling Fan
Table 4. GP400 for output 100/110/115/120 VAC specification
Note
:
:
Normal load Condition
:
Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% load
(PF=1.0)
Voltage performance
:
Please refer to Figure 2
Temperature performance
:
Please refer to Figure 3
GP-ISW-400 Specification
Electrical
Specification
Model No.
Item
GP-ISW-400-12 GP-ISW-400-24
Input
Voltage
12VDC
24VDC
Voltage Range
10.5~16.0VDC
2 1.0~32.0VDC
No Load Current
< 1A @12VDC
< 0.5A @24VDC
< 1A @12VDC
< 0.5A @24VDC
< 0.2A @12VDC
< 0.1A @24VDC
< 0.2A @12VDC
< 0.1A @24VDC
Power Saving Mode
Efficiency (Typ.)
88%
89%
On Mode @ Save Mode
On Mode @ No Load Mode
Output
Continuous Output Power
Over Rated Power
(
1
Min.)
> 400 W~460 W (100%~115%)
400 W (± 3%)
Peak Power (3 Sec.)
800 W
Frequency
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
Output Voltage
100 / 110 / 115 / 120 VAC ± 5%
(Dip Switch Selectable)
Short-Circuit Protection
1 second shutdown
Output Waveform
Pure Sine Wave (THD < 5%@ Normal Load)
Protection
Input Over-Voltage
Protection
16.0VDC ± 0.3VDC
32.0 ± 0.5VDC
Input Under-Voltage
Protection
10.5VDC ± 0.3VDC 21.0VDC ± 0.5VDC
BAT. Low Shutdown
10.5VDC ± 0.3VDC 21.0VDC ± 0.5VDC
BAT. Low Alarm
10.5VDC ± 0.3VDC 21.0VDC ± 0.5VDC
BAT. Low Restart
14.5VDC ± 0.3V
28.0VDC ± 0.5VDC
BAT. High Shutdown
16.0 ± 0.3V
32.0VDC ± 0.3VDC
BAT. High Restart
12.5VDC ± 0.3V
25.0VDC ± 0.3V
Environment
Working Temp.
-20
˚C
~ 40
˚C
Storage Temp.
-30
˚C
~ 70
˚C
Working Humidity
10~95% RH, non-condensing
Safety &
EMC
Safety Standards
EMC standards
Certified FCC class B
E-mark
----
Others
Dimension(WxHxD)
150 mm X 68mm X187 mm
Weight
1.
3
kg
Remote Control
CR-8 (optional)
Cooling
Temperature & Load Controlled cooling Fan
Table 2. GP-ISW-400 for output 100/110/115/120 VAC Specification
Certified UL 458
(UL only for GFCI receptacles)
10