gpelectric.com | [page 43]
OPERATION
4.7 BATTERY TEMPERATURE SENSOR (BTS) OPERATION
The IC Series Inverter/Charger is delivered with a battery temperature sensor. By installing this sensor, the charge voltages are
automatically adapted for deviating temperature. With a BTS installed, if the temperature around the BTS is below 20°C, the absorb and
float charge voltage increases. If the temperature around the BTS is above 20°C, the absorb and float charge voltage decreases. The
graph below details how much the charge voltage changes (increases or decreases) depending on the temperature reading of the BTS.
4.8 FACTORY DEFAULT VALUES
The IC Series Inverter/Charger uses default values for the following adjustable settings:
Adjustable Settings
Default Values
Shore Input
30 Amps (AC)
Low Battery Cut Out
10.5 VDC
VAC Dropout
85 VAC
Max Charge Time
12 Hours
Battery Type
AGM 1
Charge Rate
80%
ABS Charge Time
2 Hours
These settings are only adjustable with the GP-ICR-50 remote, which can be purchased separately from Go Power!. For detailed
information on these settings please refer to the remote control manual. The remote also displays the real time Inverter/Charger’s
operating status and allows the user to run the equalize charging profile on the battery bank.