gpelectric.com | [page 37]
BATTERY CHARGER SPECIFICATIONS
The IC Series Inverter/Charger is equipped with a PFC (Power Factor Corrected) and PI (Proportional Integral) multistage battery
charger. These 2 features maximize the real power from AC Shore Power. The multistage battery charger can use up to four
different charging stages to help monitor and keep the batteries healthy.
Bulk Charging:
This is the initial stage of charging. While bulk charging, the charger supplies the battery bank with controlled
constant current. The charger will remain in bulk charge until the absorption charge voltage is achieved.
Absorb Charging:
This is the second charging state and begins after the absorb voltage has been reached. Absorb charging
provides the batteries with a constant voltage and reduces the DC charging current in order to maintain the absorb voltage setting.
The factory default setting for absorb charging is 2 hours. After 2 hours of absorb charging, the charger switches to final charge.
Final (Float) Charging:
The third charging stage occurs at the end of absorb charging time. While final charging, the charge
voltage is reduced to the final charge voltage set point. In this stage, the batteries are kept fully charged and ready if needed
by the Inverter. The final (float) charging stage reduces battery gassing, minimizes watering requirements, and ensures the
batteries are maintained at optimum capacity.
OPERATION
Main Panel
Sub Panel
120 VAC
120 VAC
240 VAC
ON
OFF
Battery Bank
Fuse or Circuit Breaker
IC Series Inverter/Charger
DC Panel
Earth Ground (RV, Boat Ground)
Equipment Grounding Bus Bar
Negative Bus Bar
Battery Charging Voltage
BULK
ABSORPTION
FINAL
(FLOAT)
Battery Charging Current
Time
Battery Disconnect Switch
(not required if circuit breaker is used)
ON
OFF
D
C
A
B
Equalization Charging:
The EQ charging is used to stir up stratified electrolyte and to reverse any battery plate sulfation that
may have occurred. The EQ charging mode can only be used with the GP-IC-Remote, sold separately by Go Power!.
BATTERY CHARGING SET POINTS
LED Status
Gel
Flooded
AGM 1
AGM 2
Custom
Absorption
Voltage
14.1 VDC
14.6 VDC
14.3 VDC
14.5 VDC
12-16 VDC
Float
Voltage
13.6 VDC
13.4 VDC
13.1 VDC
13.5 VDC
12-16 VDC
Equalization
Voltage
15.5 VDC
15.5 VDC