5.1   OPERATING PRECAUTIONS

1.  Multiple outlet power strips with switches and circuit breakers only interrupt power to the “hot” 

receptacle terminals.  The “neutral” terminals remain powered with respect to the “ground” 

terminals.  So the strip switch may be off, but part of the device may still be powered.

2.  Inspect supply connections before use to ensure they are tight and that insulation is not 

damaged.

3.  Do not use this Inverter to power sensitive devices such as medical devices or computers.  

Do not use in ignition protected areas.

4.  Some rechargeable devices can damage the Inverter.  Check the temperature of the device 

several times when it is charging.  If the device becomes extremely hot; turn the power, 

remove the device, and do not use with the Inverter.

5.  Check for breakage of parts and any other condition that may affect the Inverter’s operation.  

If damaged, have it repaired before use.

6.  Do not attempt to power a device, or combination of devices, that will require more than 

the rated output of this Inverter.  This may damage the Inverter of the attached devices.

7.  Appliances such as microwave ovens will normally draw more than their rated current.  

For example, a typical 800 watt microwave oven will drawn approximately 1,200 watts.

8.  Do not attach a battery charger if the charger carries a warning that dangerous voltages 

are present at the battery terminals.

9. 

Some fluorescent lamps may not operate properly with this type of Inverter.  If the bulb 

appears to be too bright, or fails to light, do not use the lamp with this Inverter.

10.  Some fans with synchronous motors may slightly increase in speed when powered by the 

Inverter.  This is not harmful to the fan or to the Inverter.

11.  The Inverter will consume some power while on, even without loads attached.  Turn the 

Inverter off after use.

5. OPERATION

Содержание GP-1750HD GP

Страница 1: ...0 3000 5000HD User Manual 2017 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Corporate Headquarters 250 Bay St Victoria BC Canada V9A 3K5 Tel 1 866 247 6527 8069...

Страница 2: ...LATION AND TESTING 17 4 6 BATTERY PRECAUTIONS 19 4 7 DC WIRING SIZING 20 4 8 DC GROUNDING 21 5 OPERATION 22 5 1 OPERATING PRECAUTIONS 22 5 2 CONNECTING AC LOADS 23 5 3 CONTROLS AND INDICATORS 23 5 4 O...

Страница 3: ...national electrical codes These instructions are for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical powe...

Страница 4: ...rs to be damaged in any way See the Warranty section for instructions on returning the equipment WARNING Hazard to Human Life This type of notation indicates that the hazard could be harmful to human...

Страница 5: ...k and utility grid components If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired People with pacemakers should consult thei...

Страница 6: ...NING Fire Hazard Do not keep combustible or flammable materials in the same room with the equipment Some products contain relays with moving parts and are not ignition protected Ensure AC DC and groun...

Страница 7: ...smoke or allow a spark or flame near the batteries Always use insulated tools Avoid dropping tools onto batteries or other electrical parts Never charge a frozen battery Never use old or untested bat...

Страница 8: ...s If battery acid contacts skin or clothing wash immediately with soap and water If acid enters the eye immediately flood it with running cold water for at least 20 minutes and get medical attention a...

Страница 9: ...ect reliable or current The specifications in this manual are for reference purposes only and are subject to change without notice For additional information please see www gpelectric com DISCLAIMER G...

Страница 10: ...ZE THIS TABLE MATERIAL FINISH FINISH SPEC COLOR A B C 6 7 8 ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT CERTIFICATE REQUIRED WITH INITIAL SHIPMENT NOTES 1 TYPE YOUR NOTES IN HERE 2 FEEL FREE TO...

Страница 11: ...DESIGN AUTHORITY PDM MAINTAINED DATA COPYRIGHT 2012 BY Carmanah Technologies Corp Victoria BC Canada ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED STORED IN A RETRIEVAL SYSTEM OR TRA...

Страница 12: ...n System Shutdown USB Output Voltage 4 75 5 25 VDC 2 1 A Output Waveform Modified Sine Wave AC Output Connections 3 Standard North American Outlets USB Connections 1 USB Ports Signal and Control Remot...

Страница 13: ...System Shutdown USB Output Voltage 4 75 5 25 VDC 2 1 A Output Waveform Modified Sine Wave AC Output Connections 4 Standard North American Outlets USB Connections 1 USB Ports Signal and Control Remote...

Страница 14: ...System Shutdown USB Output Voltage 4 75 5 25 VDC 2 1 A Output Waveform Modified Sine Wave AC Output Connections 4 Standard North American Outlets USB Connections 1 USB Ports Signal and Control Remote...

Страница 15: ...olarity properly Incorrect connection will damage the Inverter and void warranty 6 Keep the Inverter dry and clean Do not expose to rain snow spray bilge water or dust 7 Use cables that are the approp...

Страница 16: ...down if its internal temperature gets too high Note even though this Inverter has built in mechanisms to minimize damage these situations should be avoided because they can still damage the Inverter...

Страница 17: ...emember the terminal is positive and the terminal is negative Place the lug connector between the washers and tighten the terminal screw or nut to clamp the wires securely Ensure connections are tight...

Страница 18: ...the presence of flammable fumes as explosion or fire may result 8 Set the power switch to the ON position Check the meters and indicators on the front panel of the Inverter The Function LEDs should be...

Страница 19: ...ly rated fuse on the positive output of the battery bank See section 4 7 DC WIRING SIZE The following points must be observed for the DC Wiring The DC positive and negative cables connected to the Inv...

Страница 20: ...put current to prevent frequent low input voltage warnings and shutdown Only use high quality copper wire The cables should be as short as possible and the overall length of both cables added together...

Страница 21: ...s sometimes referred to as the Earth ground or another designated ground For example on an RV the metal frame of the RV is designated as the negative DC ground RV ground The DC ground wire connection...

Страница 22: ...other condition that may affect the Inverter s operation If damaged have it repaired before use 6 Do not attempt to power a device or combination of devices that will require more than the rated outp...

Страница 23: ...ge the battery to the point that it will no longer start the engine If needed operate the engine periodically to maintain the batteries charge Do not operate a vehicle s engine in an enclosed space 5...

Страница 24: ...f the motor refuses to start observe the battery voltage indicator while trying to start the motor If the battery voltage indicator drops below 11V while the Inverter is attempting to start the motor...

Страница 25: ...arged but the voltage still drops below 11 volts you may need to use a larger battery OPERATION 5 6 INPUT VOLTAGE The Inverter will operate from input voltage ranging 10 5 16V If the voltage drops bel...

Страница 26: ...replace battery 5 Clean and tighten connection 6 Remove charging source and make sure correct battery is being used and connected correctly Output voltage is incorrect Input voltage is too high or to...

Страница 27: ...erson using only identical replace ments This will ensure that the safety of the Inverter is maintained 4 Fuses must be replaced with fuses of the same type and rating only 7 2 MAINTENANCE Very little...

Страница 28: ...tion of our website to troubleshoot the problem If trouble persists 1 Call your Go Power Technical Support team 1 866 247 6527 or 2 Return defective product to place of purchase Unless approved by Go...

Страница 29: ...appliances are being recycled properly is tricky If you re in doubt just ask Recyclers that are certified should gladly show you their certification If the re cycler is certified chances are very high...

Страница 30: ...ric com 2017 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Corporate Headquarters 250 Bay St Victoria BC Canada V9A 3K5 Tel 1 866 247 6527 80691_MANUAL_GP 1750 3...

Отзывы: