www.g-mw.de
33
9.17 Wiring test (only in the Test-Master app)
Wiring test for a non-heating appliance cable, extension cable or a CEE extension via an automatic test
sequence with the Test-Master app.
1. The non-heating appliance cable is tested on TG Basic 2 via the included adapter for testing
non-heating appliance plugs A2 or the shockproof extension via the adapter for testing extension
cables A1.
2. A non-heating appliance plug cable or a shockproof extension cable can be tested directly on the
device via the integrated non-heating appliance plug of the „TG Basic 2+“. The limit value should be
between 0.17-0.28 MOhm. If the value measured is below the limit, there is probably a wiring error.
Cannot be measured via individual measurements on the appliance!
9.15 Clip-on ammeter function test (TG Basic 2+ only)
Connect the TGSZ 40 clip-on ammeter to test device TG Basic 2+ at the clip-on ammeter connection (15).
This cannot be implemented via an automatic sequence in the app!!!
For individual measurements on the appliance, select „Clip-on ammeter function test“ under
. Carry out the test
9.16 RCD function test (for TG Basic 2+ only )
This cannot be implemented via an automatic sequence in the app!!!
For individual measurements on the appliance, select ‘Clip-on ammeter function test’ under
.
Carry out the test.