3.2.3
VALVE INPUTS INTERFACE
Connettor X13, step 5,0 mm (vedi Jumpers per tensioni)
Pos. Mark
Features
Description
J2
H
L
C
V
C
V
V
D
V
P
E
M
+
E
M
-
VBP
CV
VMD
CV
EM+EM-
P1+
T-
T+
P1- P2+P2-
+
-
S1
-
X8
X9
X10
X
13
X7
J
6
1
VD
24…60Vdc/ac,
80…180Vdc (230Vac)
Input command down direction
2
CV
Comune
Common VD-VP, bridge with
X5.CV3 (8)
3
CV
Comune
Common VD-VP
4
VP
24…180Vdc (230Vac)
Input voltage for bypass solenoid
VBP
5
EM+ Positivo
Intput voltage for emergency
solenoid
6
EM-
Negativo
3.2.4
JUMPERS
Jumper J4, Boot (µchip)
Connector for factory programming of the flash memory of the
µ
Chip.
Can only be performed by GMV technicians, properly trained and authorized,
using dedicated software.
+
-
S1
-
S2
+
-
S3
+
X11
X12
X13
LV1
LR1
J5
BAT1
J2
J1
J3
X14
J
4
Jumper J6 (to set connector X13)
Pos.
Description
H
L
C
V
C
V
V
D
V
P
E
M
+
E
M
-
VBP
CV
VMD
CV
EM+EM-
P1+
T-
T+
P1- P2+P2-
+
-
S1
-
X9
X10
X11
X
7
X8
J2
J
6
J2
H
L
C
V
C
V
V
D
V
P
E
M
+
E
M
-
VBP
CV
VMD
CV
EM+EM-
P1+
T-
T+
P1- P2+P2-
+
-
S1
-
X8
X9
X10
X
1
3
X7
J
6
L
VMD and VBP Voltage = 24…60Vdc/ac
H
VMD and VBP Voltage = 80…180Vdc (230Vac)
Jumper J7 (to set connector X5)
Pos.
Description
L
H
L
L
H
L
H
LD
0V
+24
LC
SC- SC1 SC2 SC3 SC-
VMP CV1 VML CV2 CV2 AUX CV3 CV3
+
IN
0
0
P
E
X
1
6
J
7
J
8
J
9
X
5
X
4
J
6
X
6
4
1
L
H
L
L
H
L
H
LD
0V
+24
LC
SC- SC1 SC2 SC3 SC-
VMP CV1 VML CV2 CV2 AUX CV3 CV3
+
IN
0
0
P
E
X
1
6
J
7
J
8
J
9
X
5
X
4
J
6
X
6
4
1
L
VMP Voltage = 24…60Vdc/ac
H
VMP Voltage = 80…180Vdc (230Vac)
Jumper J8 (to set connector X5)
Pos.
Description
L
H
L
L
H
L
H
LD
0V
+24
LC
SC- SC1 SC2 SC3 SC-
VMP CV1 VML CV2 CV2 AUX CV3 CV3
+
IN
0
0
P
E
X
1
6
J
7
J
8
J
9
X
5
X
4
J
6
X
6
4
1
L
H
L
L
H
L
H
LD
0V
+24
LC
SC- SC1 SC2 SC3 SC-
VMP CV1 VML CV2 CV2 AUX CV3 CV3
+
IN
0
0
P
E
X
1
6
J
7
J
8
J
9
X
5
X
4
J
6
X
6
4
1
L
Tensione VML = 24…60Vdc/ac
H
Tensione VML = 80…180Vdc (230Vac)
Jumper J9 (to set connector X5)
Pos.
Description
L
H
L
L
H
L
H
LD
0V
+24
LC
SC- SC1 SC2 SC3 SC-
VMP CV1 VML CV2 CV2 AUX CV3 CV3
+
IN
0
0
P
E
X
1
6
J
7
J
8
J
9
X
5
X
4
J
6
X
6
4
1
L
H
L
L
H
L
H
LD
0V
+24
LC
SC- SC1 SC2 SC3 SC-
VMP CV1 VML CV2 CV2 AUX CV3 CV3
+
IN
0
0
P
E
X
1
6
J
7
J
8
J
9
X
5
X
4
J
6
X
6
4
1
L
Tensione AUX = 24…60Vdc/ac
H
Tensione AUX = 80…180Vdc (230Vac)
3.2.5
EXTENSIONS INTERFACE
Connettor X14, step 2,54 mm - (AUX 2 x 13))