ENG
1.00
1 0991 491
EN
-
23.08.2016
37 / 45
NGV-EK
V
ALVE
M
ANUAL
I
NSTALLATION
,U
SE AND
M
AINTENANCE
8.4
OUTPUT 41-42
FUNXXXX
Active function on output 41-42. Every function is identified by a code
described into
Output Programmable Functions Chart
As default the output are set up with this functions: (for other functions see § Errore. L'origine riferimento
non è stata trovata. ) :
•
Output 10-12: Alarm (09NO)
•
Output 21-22: Overload (08NO)
•
Output 31-32: Maximum pressure (02NC)
•
Output 41-42: Minimum pressure (01NC)
- 9 -
TEST
NGV-EK01
9-TEST…
9.1
OVERP. VALUE
ENT=Start
Start the routine for the control of the adjusted pressure on the
overpressure valve. For the overpressure value test please refer to the
Overpressure Valve (VS) Adjustment chapter.
This routine needs VS and V0 input signals for working.
Press ENT to start the routine. The display blinks while the routine is
working, at the end of the routine the fixed value is the adjustment value
of the overpressure valve.
Press ESC to exit and ENT to start again.
9.2
PIPE RUPTURE
ENT=Start
Start the routine for the test of the pipe rupture valve. For the pipe rupture
valve test please refer to the
Pipe Rupture (VC) Test chapter.
This routine needs D and V0 input signals for working.
Press ENT to start the routine. The routine is ended when the D signal
falls down.
Press ESC to exit and ENT to start again.
9.3
UCM UP TEST
ENT=Start
Start the routine that allows to simulate the unintended car movement in
up direction
To use this function see the chapter
Test in Up direction
This routine needs that the control panel works in normal mode (not
inspection)
Press ENT to start the routine. Press ESC to end/exit.
9.4
UCM DN TEST
ENT=Start
Start the routine that allows to simulate the unintended car movement in
down direction
To use this function see the chapter
Test in Down direction
This routine needs that the control panel works in normal mode (not
inspection)
Press ENT to start the routine. Press ESC to end/exit.
9.5
VB TEST DOWN
ENT=Start
U
SED
ONLY
TO PERFORM FACTORY TESTS
9.6
VB TEST UP
ENT=Start
U
SED
ONLY
TO PERFORM FACTORY TESTS
9.7
S3 TUNING
ENT=START
Start the routine that allows to place the sensor S3 in the correct position.
The routine open the VB allowing to move the sensor in the exact lighting
position. To use this function see chapter 6
Adjusting of the sensors.
Press ESC to end
- 10 -
ADVANCED PROGRAMMING
NGV-EK01
10-ADVANCED
10.1
PASSWORD
±00000
Entering the password it’s possible to read and modify the entire
parameters of the NGV valve
10.2
REGISTERS
RNNN = ±00000
Complete parameter list with the set value
- 11 -
PARAMETERS ON MICRO SECUR DIGITAL