HOW TO USE CONTROL PANEL
③ "BURST:615" - Bursting Timing Display
Operation point for Bursting Roller. Bursting Point range is "580 ~ 660"mm (for DUAL : "760 ~ 840"mm).
NOTE :
Refer to he Explanation of Control Panel to set up the Bursting Timing.
④ "LENGTH:0635" - Paper Length Display
Displayed value means paper length. Then, put a length for lamination.
Its setting range is (for MANUAL MODE : "203 ~ 1,219"mm) (for AUTO MODE : "254 ~ 813"mm).
NOTE :
Refer to the PAPER LENGTH in Explanation of Control Panel to set up.
⑤ "SPD:03" - Roller Speed Display
To display Laminating Roller Speed. Its setting range is "1 ~ 15".
NOTE :
Refer to the SPEED in Explanation of Control Panel to set up. In initial job, start at lower speed.
⑥ "READY" - Roller Temp. Display
To display Ready for Lamination. It displays "WAIT" or "READY".
- "W"(WAIT) : Not suitable for lamination(Temp. is higher or lower for lamination).
- "R"(READY) : Good for lamination. Start lamination.
⑦ "C:0038" - Counter Display
Counter for sheet for a certain time period. It can be reset if it is required.
☞ Counter Reset :
Press "SPEED" button & "MASTER DIAL" button at the same time or turn off the power and turn it on again.
But, the previous data is not saved.
⑧ "MAN" - Feeding Display
To show feeding method. This is composed of "MAN"(Manual Feeding) & "AUTO"(Automatic Feeding).
NOTE :
To change the feeding method, refer to the MASTER DIAL in Explanation of Control Panel.
⑨ Error Message Display
When error is occurred, if the RUN button is pressed, a message is displayed. In this status, the machine cannot be operated.
NOTE :
Refer to the Error Message for display.
18/48
Содержание PROTOPIC III-540
Страница 8: ...WARNING STICKERS Warning Stickers 8 48...