Setting the Temperature
1) How to set the Temperature
Press ‘TOP TEMPERATURE’ key or ‘BOTTOM TEMPERATURE’ key on the control panel
and turn the Jog Dial left or right to set the desired temperature. Once the temperature
is selected, the setting will automatically stored in the memory after 2 seconds.
2) READY and WAIT Display
READY means the actual temperature has reached the set(target) temperature.
Push the ‘START’ button to start operating. If the actual temp. becomes lower than the
set temp.,‘WAIT(Too COLD)’ will be displayed and ‘WAIT(Too HOT)’ will be displayed
in opposite case. In any case, wait till ‘READY’ comes on in order to operate the unit.
T O P > 1 1 0 C S P E E D > 0 5
B O T > 1 1 0 C R / T > 0 0 : 0 0
M O D E > M i d - P r s L A M I
W A I T ( T o o C O L D )
T O P > 1 2 0 C S P E E D > 0 5
B O T > 1 2 0 C R / T > 0 0 : 0 0
M O D E > L o w - P r s L A M I
W A I T ( T o o H O T )
T O P > O V E R H S P E E D > 0 5
B O T > O V E R H R / T > 0 0 : 0 0
M O D E > M i d - P r s L A M I
W A I T ( T o o H O T )
3) Roller Over-heating
The unit display “OVERH(OVER HEAT)” when the actual temp. exceeds 160 .
Release the rollers and turn off the unit power, then contact GMP agent for support.
* T O P > 1 1 0 C S P E E D > 0 5
* B O T > 1 1 0 C R / T > 0 0 : 0 0
M O D E > M i d - P r s L A M I
W A I T ( T o o C O L D )
4) Actually Roller Temperature Display (Measure Temp. Function)
‘*’mark will flash while the Jog Dial is pressed to measure current temperature.
15
T O P > 1 1 0 C S P E E D > 0 4
B O T > 1 1 0 C R / T > 0 0 : 0 0
M O D E > H i g h - P r s L A M I
P o s i t i o n i n g . . .
Top Temp, Bottom Temp, Speed, Roller Pressure, Vacuum Fan Power, Cooling
Fan Power will all vary on their own depending on above settings. It takes from 1
to 10 seconds for the unit to set the proper roller gap when the mode is changed
T O P > 1 2 0 C S P E E D > 0 5
B O T > 1 2 0 C R / T > 0 0 : 0 0
M O D E > L o w - P r s L A M I
P o s i t i o n i n g . . .
10mm Mounting
T O P > 0 0 0 C S P E E D > 0 5
B O T > 0 0 0 C R / T > 0 0 : 0 0
M O D E > 1 0 mm M o u n t i n g
P o s i t i o n i n g . . .
15mm Mounting
T O P > 0 0 0 C S P E E D > 0 5
B O T > 0 0 0 C R / T > 0 0 : 0 0
M O D E > 1 5 mm M o u n t i n g
P o s i t i o n i n g . . .
20mm Mounting
T O P > 0 0 0 C S P E E D > 0 5
B O T > 0 0 0 C R / T > 0 0 : 0 0
M O D E > 2 0 mm M o u n t i n g
P o s i t i o n i n g . . .
25mm Mounting
T O P > 0 0 0 C S P E E D > 0 5
B O T > 0 0 0 C R / T > 0 0 : 0 0
M O D E > 2 5 mm M o u n t i n g
P o s i t i o n i n g . . .
Mode will be changing as per each mounting thickness settings
Note) When you perform Hot Laminating with Mounting Board (EX:GMP Foam
Pouch), Top Roller Temp. 100 (Recommended Temperature) and set the
Mounting Board thickness & speed.
16