TBE-D5001-TRI-xxx

 - SIL 3 HART® multiplexing Termination Board for Tricon & Tricon CX systems 

G.M. International ISM0579-0 

125 [4.

9”

29 [

1.1”

154 [6.

0”

125 [4.

9”

29 [

1.1”

154 [6.

0”

 

Models mounting and removing 

Mounting: 

To mount termination board on 35 mm DIN-Rail, hook one side of the mounting foot over 
the rail’s lip and press the Termination Board down firmly until fixed (see Fig.1). 

Removing: 

To remove a termination board from the mounting rail, insert a blade screwdriver in the 
mounting foot and lever (see Fig. 2). 

Overall dimensions 

For all termination boards TBE-D5001-TRI-xxx. 

With 2 x Plastic DIN-Rail clips TBE-FIX-PL-001, with all dimensions are expressed in millimeters [inches]: 

 With 2 x Metal DIN-Rail clips TBE-FIX-MT-002, with all dimensions are expressed in millimeters [inches]: 

Fig. 2

 

Pull the termination board upwards 

and remove from DIN-Rail 

For termination board with 2 x Plastic DIN-Rail clips TBE-FIX-PL-001: 

Fig. 4

 

Pull the termination board upwards 

and remove from DIN-Rail 

Push to 
engage 

Fig. 3

 

73 [2.9”] 

235 [9.3”] 

12 [0.5”] 

77 [

3.0”

58 [

2.3”

135 [5.

3”

73 [2.9”] 

39 [1.5”] 

39 [1.5”] 

235 [9.3”] 

77 [

3.0”

58 [

2.3”

135 [5.

3”

5 [0.2”] 

Fig. 1

 

Push to 
engage 

Mounting: 

To mount termination board on 35 mm DIN-Rail, hook one side of the mounting foot over 
the rail’s lip and press the Termination Board down firmly until fixed (see Fig.3). 

For termination board with 2 x Metal DIN-Rail clips TBE-FIX-MT-002: 

Removing: 

To remove a termination board from the mounting rail, insert a blade screwdriver in the 
mounting foot and lever (see Fig. 4). 

Содержание TBE-D5001-TRI Series

Страница 1: ...ination Board for Tricon Tricon CX systems G M International ISM0579 0 SIL 3 HART Multiplexer Termination Board with SIL 3 HART Multiplexer Modem 5700 series for Tricon and Tricon CX systems TBE D5001...

Страница 2: ...PWR 1 24 Vdc PWR 1 RS485 connection 1 RS485 connection 2 Warning Termination Boards are installed onto standard EN IEC60715 TH 35 DIN Rail located in Safe Area or Ordinary Location within the specifie...

Страница 3: ...boards TBE D5001 TRI xxx place the enclosure as shown in the following figures and fix each Plastic or Metal DIN Rail clip to enclosure by 2 x M3 10 mm screws included on TBE FIX set With 2 x Plastic...

Страница 4: ...ed in millimeters inches With 2 x Metal DIN Rail clips TBE FIX MT 002 with all dimensions are expressed in millimeters inches Fig 2 Pull the termination board upwards and remove from DIN Rail For term...

Страница 5: ...rd supports 32 channels Yet it could be extended with additional units up to 8 to manage all 256 channels available on the HART Modem 5700 series The Mux unit connects via the RS 485 interface to an e...

Страница 6: ...TBE D5001 TRI xxx SIL 3 HART multiplexing Termination Board for Tricon Tricon CX systems G M International ISM0579 0 6 Termination Board Description...

Страница 7: ...TBE D5001 TRI xxx SIL 3 HART multiplexing Termination Board for Tricon Tricon CX systems G M International ISM0579 0 7 Function Diagram and Termination Board Network...

Отзывы: