GASURVEYOR 500 USER HANDBOOK
ii
SAFETY
•
The instrument must be regularly serviced and calibrated by fully trained
personnel in a safe area.
•
Batteries: Alkaline batteries or *Rechargeable battery pack must be exchanged
(*and recharged) in a safe area and fitted correctly before use.
Never use damaged batteries or expose to extreme heat.
See Section 4 : OPERATOR MAINTENANCE.
•
Only GMI replacement parts should be used.
•
If the instrument detects gas, follow your own organisation’s procedures and
operational guidelines.
•
The combustion chamber is a flameproof assembly and must not be opened in
the presence of a flammable atmosphere.
•
Gasurveyor 500 series instruments are certified as EEx iad IIC T4
(-20oC< Tamb < 50oC). BAS01ATEX2292
II 2 G.
UL Class 1 Groups A, B, C and D
•
This equipment is designed and manufactured to protect against other hazards
as defined in paragraph 1.2.7 of Annex II of the ATEX Directive 94/9/EC.
Any right of claim relating to product liability or consequential damage to any third party
against GMI is removed if the warnings are not observed.
AREAS OF USE
Exposure to certain chemicals can result in a loss of sensitivity of the flammable sensor.
Where such environments are known or suspected it is recommended that more frequent
response checks are carried out. The chemical compounds that can cause loss of
sensitivity include Silicones, Lead, Halogens and Sulphur. Do not use instrument in
potentially hazardous atmospheres containing greater than 21% Oxygen. The enclosure
material is polypropylene and must not be exposed to environments which are liable to
result in mechanical or thermal degradation or to damage caused by contact with
aggressive substances. Additional protection may be required in environments where the
instrument enclosure is liable to damage.
STORAGE, HANDLING AND TRANSIT
The batteries in the rechargeable pack contain considerable energy and care should be
taken in their handling and disposal. Battery packs should be removed if the instrument is
stored for longer than 3 months. The instrument is designed to handle harsh environments.
The sensing elements are sealed to IP54 and the rest of the instrument to IP64. If not
subject to misuse or malicious damage, the instrument will provide many years of reliable
service. The instrument contains electrochemical sensors with a life of 2 years. Under
conditions of prolonged storage the sensors should be removed. The sensor contains
potentially corrosive liquid and care should be taken when handling or disposing of the
sensor, particularly when a leak is suspected.
Содержание Gasurveyor 500 Series
Страница 1: ...Gasurveyor 500 User Handbook Distributed By 713 844 1300 info heathus com www heathus com...
Страница 6: ...GASURVEYOR 500 USER HANDBOOK iv...
Страница 8: ...GASURVEYOR 500 USER HANDBOOK...
Страница 14: ...GASURVEYOR 500 USER HANDBOOK xii...
Страница 18: ...GASURVEYOR 500 USER HANDBOOK 1 4...
Страница 31: ...3 3 OPERATION Figure 3 2 CSM Warm Up Note Battery status is displayed as either OK or LO at start up...
Страница 54: ...GASURVEYOR 500 USER HANDBOOK 6 4...
Страница 56: ...GASURVEYOR 500 USER HANDBOOK 7 2...
Страница 60: ...GASURVEYOR 500 USER HANDBOOK A 4...
Страница 70: ...GASURVEYOR 500 USER HANDBOOK B 10...
Страница 96: ...C 26 GAS MEASUREMENT INSTRUMENTS LTD...
Страница 101: ......