- SIL 3 Switch/Proximity Interface 

G.M. International ISM0113-7 

Ordering Information 

 

Front Panel and Features 

 



SIL 3 according to IEC 61508:2010 Ed. 2 for Tproof = 1 / 10 yrs (

10% / >10 % of total SIF). 



SIL 2 according to IEC 61508:2010 Ed. 2 for Tproof = 17 / 20 yrs (

10% / >10 % of total SIF). 



PFDavg (1 year) 5.65 E-05, SFF 90.86 %. 



Systematic capability SIL 3 



2 fully independent channels. 



Input from Zone 0 (Zone 20), installation in Zone 2. 



Transparent mode operation. 



Field open and short circuit detection available to the PLC/DCS card. 



Input and Output short circuit proof 



High Accuracy. 



Three port isolation, Input/Output/Supply. 



EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system. 



ATEX, IECEx, UL & C-UL, FM, FMC, INMETRO, EAC-EX, UKR TR n. 898, NEPSI, TÜV Certifications. 



TÜV Functional Safety Certification. 



Type Approval Certificate DNV and KR for maritime applications. 



High Density, two channels per unit. 



Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus, or customized Termination Boards. 



250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. 

+ Input Ch 1 for Proximity or Voltage free Contact 

Terminal block connections 

HAZARDOUS AREA 

SAFE AREA 

- Input Ch 1 for Proximity or Voltage free Contact 

+ Input Ch 2 for Proximity or Voltage free Contact 

- Input Ch 2 for Proximity or Voltage free Contact 

7

 

8

 

9

 

10

 

+ Output Ch 1 

1

 

- Output Ch 1 

2

 

+ Output Ch 2 

3

 

- Output Ch 2 

4

 

+ Power Supply 24 Vdc 

5

 

- Power Supply 24 Vdc 

6

 

7 8 

9 10 

4 3 

6 5 

Model:  

D5034 

1 channel 

2 channels 

Power Bus and DIN-Rail accessories: 
Connector JDFT049 

 

Cover and fix MCHP196 

Terminal block male MOR017 

Terminal block female MOR022 

Содержание D5034S

Страница 1: ...D5034 SIL 3 Switch Proximity Interface G M International ISM0113 7 SIL 3 Switch Proximity Interface DIN Rail and Termination Board Models D5034S D5034D D5034S D5034D INSTRUCTION SAFETY MANUAL...

Страница 2: ...to max supply change Load influence 0 05 of full scale for a 0 to 100 load resistance change Temperature influence 0 03 of full scale on zero and span for a 1 C change Compatibility CE mark compliant...

Страница 3: ...TR n 898 NEPSI T V Certifications T V Functional Safety Certification Type Approval Certificate DNV and KR for maritime applications High Density two channels per unit Simplified installation using s...

Страница 4: ...ve group See parameters indicated in the table below D5034 Terminals Ch1 Ch2 7 8 9 10 Ch1 Ch2 7 8 9 10 Io Isc 15 mA Ch1 Ch2 7 8 9 10 Po Po 39 mW Ii Imax Pi Pi D5034 Terminals D5034 Associated Apparatu...

Страница 5: ...ector Power Bus PLC In 1 Proximity voltage free Contact In 2 Proximity voltage free Contact voltage free Contact voltage free Contact R1 R2 R1 R2 MODEL D5034S 5 6 1 2 7 8 mA Out SIL 3 RL PLC Terminati...

Страница 6: ...at causes the output signal to go above 7 mA as short circuit of input Assuming that the application program in the safety logic solver is configured to detect High failure and does not automatically...

Страница 7: ...field in order to go to open connection condition equivalent to line breakage and verify that the output current of the repeater reaches low current value 0 35 mA This tests for possible quiescent cur...

Страница 8: ...ew terminal blocks which can be plugged in out into a powered unit without suffering or causing any damage for Zone 2 installations check the area to be nonhazardous before servicing The wiring cables...

Отзывы: